What is the best MAX charge voltage for LiFePo4? Tested!

Поділитися
Вставка
  • Опубліковано 29 вер 2024

КОМЕНТАРІ • 237

  • @CraigDohner
    @CraigDohner 3 роки тому +18

    A lot of questions I had about this were answered in this video. I'm glad to have found that someone spent the time to do this.

  • @SS-im3kb
    @SS-im3kb 3 роки тому +29

    I just lowered my charge voltage to 3.55V/cell. This seems entirely reasonable and builds in more safety margin. Thanks

    • @cjdelphi
      @cjdelphi 7 місяців тому

      I've charged all mine to 14.1 or 3.525v per cell
      Maybe i need to slightly raise the voltage?

    • @Francois_Dupont
      @Francois_Dupont Місяць тому

      3.45 is actually best for long term.

  • @davehayes8812
    @davehayes8812 3 роки тому +17

    Nice work.
    I did similar testing and came up with 3.4 to 3.45V Max, also very little point in discharging below 3.0v.

    • @wole04
      @wole04 Рік тому +1

      3v? Wow. You will use hardly any capacity. I use a victron smart shunt and I still have about 150a left in a 400a pack at 3v per cell. That's still a lot of useful energy ⚡
      I typically discharge to 2.8v at which point, I have 80a left in the battery bank which is manageable for a 400a battery pack. I think the cells are safe and in a good window at 2.8v
      The danger is discharging to 2.6v often which could lead to damage. The bms cut off is at 2.5v

    • @davehayes8812
      @davehayes8812 Рік тому +3

      @@wole04 interesting!
      Check the discharge curve on your cell chemistry. The curves on my lefepo4 drop like crazy below 3v, meaning there's not much capacity below 3v.

    • @Hinapulan
      @Hinapulan 4 місяці тому

      3.2 v as standard lower voltage limit is even better. More cycle life.

  • @vincentrobinette1507
    @vincentrobinette1507 5 місяців тому

    For solar, I'll probably set for 3.5 volts per cell. For floating, I set for 3.475. 3.65 volts should be considered a "withstand" voltage, rather than a "finishing" voltage for charging. While it's safe to discharge to 2.5 volts per cell, I find that the voltage starts rolling off sharply below 3 volts per cell. For day to day cyclic use, I recommend charging to 3.5 volts, then discharging only down to 3 volts even per cell. That will give you ~95% capacity usable, while minimizing degradation.

  • @benoitarteau2078
    @benoitarteau2078 3 роки тому +1

    Cool test! For me the best is 3.55v! That save the battery a little and no difference with the capacity!

  • @immrnoidall
    @immrnoidall 3 роки тому +1

    My iMAX B6 Multi Charger is 3.6 volt , on the lifepo setting. you can put it on 5 amp charge , but it automatically decreases as it charges. like most lead acid chargers do when charging lead acid.

  • @peterlindstrom8865
    @peterlindstrom8865 3 роки тому +1

    Great video and many thanks! Btw, the link for the Capacity Tester on Ali Express doesn't work. I just get to their front page. What is the name of this tester?

  • @dbfcrell8300
    @dbfcrell8300 4 місяці тому

    I'm not technically battery savvy, but do these charge/discharge numbers apply to just the LiFePos you're testing or to all LiFePos at all voltages? I have a 2015 48V 21Ah LiFePo4 Chinese escooter battery with a typical plug&play charger AND an adjustable Grin charger. What specs make for the best charge rates of this battery? BTW, I generally charge it to full and use it right away. I also store it for the winter at 50%soc.

  • @VolkanBay
    @VolkanBay 3 роки тому

    Good job

  • @DSmartLife
    @DSmartLife 3 роки тому +1

    Good test but your electronic load cutoff at 2.5V is not accurate as you are not sensing the batt voltage at the terminals. That tester has separate current and voltage terminals for you to sense the voltage at the batt terminals. Hope you use it next time.

    • @SolarEngineering
      @SolarEngineering  3 роки тому +4

      Do you feel this causes tests to be inaccurate?
      I think for this case it doesn't matter, I'm monitoring voltage directly from the cell using Arduino so all graphs are pretty accurate.
      Load is just discharging cell (same condition for all 3 tests), maybe if I run other wires from cell to load, I'll get a few extra mA, but still, it's going to be the same mA for all 3 tests.

    • @DSmartLife
      @DSmartLife 3 роки тому +2

      @@SolarEngineering I'm not arguing, just merely suggesting to use a feature that is made available for more AH/WH accuracy. We don't know how much AH or mAH is left in the cell because the cutoff happened earlier than 2.5V. In a 25AH cell with 5A discharge it may not be much but e.g. if you measure your 280AH cells at 20A then you can see a huge difference. And also you can measure an accurate WH with voltage sensing. Anyways your tests itself may be accurate as it's a comparison with the same load.

    • @SolarEngineering
      @SolarEngineering  3 роки тому +2

      @@DSmartLife I see, thank you for the suggestion, appreceated.

  • @zakirkptcl
    @zakirkptcl Рік тому

    19s 60.8v 30ah lfp battery charge which volts are best charger 67.2v/68.4v/69.35v and amps 6a/10a for electric vehicle

  • @davyp2993
    @davyp2993 3 роки тому +1

    hmm,?
    I have just purchased 8- 500ah 3.2v Lifepo4 cells, which will eventually be configured into two 2 - 500ah 12v "batteries".
    I will connect the cells in parallel to balance the cells for their first charge to balance the cells.
    Charging at 5a it will take 33 days to fully charge the cells.!
    Have you any advice.?

    • @SolarEngineering
      @SolarEngineering  3 роки тому +1

      checkout this video ua-cam.com/video/X_ucHHnh4Ik/v-deo.html from 7:40

  • @andyronan1202
    @andyronan1202 9 місяців тому

    Cool😊

  • @chevaliercognac8757
    @chevaliercognac8757 6 місяців тому

    Хороший ролик, как называется ваше зарядное устройство?
    Спасибо.

    • @SolarEngineering
      @SolarEngineering  6 місяців тому

      variable power bench supply, на амазоне большой выбор

  • @makskoma
    @makskoma Рік тому

    Possibly to use in car in very hot country?
    At summer in closed car can be 90 celcius hot

    • @SolarEngineering
      @SolarEngineering  Рік тому

      LFP rated upto 50C.
      90 will cause accelerated degradation.

  • @mhpreach
    @mhpreach 2 роки тому

    I have 2 lifePO4 12v 8Ah I bought the first of this month. I bought a charge you have to set type of battery number of cells, voltage, etc. I tried to see the charger work. When I hook either battery up and try to start the charge I get a cell warning on both and no charge. My other charger gives me a cell balance problem. What do you think? I just got one of the Miady 20ah batteries today. The charger is at my office so haven’t had a chance to try it with either charger.

    • @SolarEngineering
      @SolarEngineering  2 роки тому

      Hi, I need more details: battery model, charger model. Do you connect battery balancing leads to the charger? If not then here is why the charger shows an error.

    • @mhpreach
      @mhpreach 2 роки тому

      @@SolarEngineering the charger is a HiTec RDX1 Multicharger. I don’t see how to setup balancing for the battery since can’t get to the individual cells. I have an imax charger as well. I didn’t know at the time that Bioenno sold a charger that didn’t require the balancing would have bought it. But, now I hate to buy another charger. I’m using these batteries for portable Ham Radio operation.

    • @mhpreach
      @mhpreach 2 роки тому

      Finally found the issue. Had to go into system settings and turn off balance charge.

  • @hargeaux
    @hargeaux 2 роки тому

    what happens if you wait about 30 minutes between charging and discharging?

    • @SolarEngineering
      @SolarEngineering  2 роки тому

      The voltage of the cells will drop to ~3.45V (if I understood your question correctly)

    • @hargeaux
      @hargeaux 2 роки тому

      @@SolarEngineering yep. is that an important fact to highlight when comparing LFP charge graphs?
      aren't most charge graphs based on resting voltage, not charge/discharge voltage?
      I feel resting voltage isn't highlighted enough by many people.

  • @electrojessy4270
    @electrojessy4270 3 роки тому +6

    So if you need to charge the battery fast.( to small battery) use 3.65 if you want youre battery to live longer use 3.55v.

  • @electrodacus
    @electrodacus 3 роки тому +4

    You will be using a BMS so you do not need safety margins as the BMS should stop charging when any cell gets to say 3.55V. Lithium batteries of any type do not like absorption and float charging so when any cell gets to set limit (I prefer 3.55V) then charging should completely stop until battery is discharged enough to re-enable the charging.
    It only takes seconds to get from 3.55V to 3.65V so not quite sure how you did the 3.55 and 3.65V test same with 3.45V it should not take long if current was maintained to 5A. Your wires where to high resistance and thus the reason for this sort of results. You should use much thicker and shorter wires or have separate voltage sense wires so 4 wire measurement.

  • @User1462uuw8w
    @User1462uuw8w 4 місяці тому +1

    In my case, I see, that voltage over 3,5v per cell give us faster charge, but deviation between cells increase more and more, so Neey Smart 4Amper active balancer does a lot of job for balance higher cells. Charge at nearly 3,430 never give any deviation more then 0,010mv, and there is no need for using Active Balancer, only bms (Daly 200A 200mv balace current) is sufficient.

  • @GoatZilla
    @GoatZilla 6 місяців тому +1

    uh... didn't answer the lifespan question though.

  • @rcfreakamit
    @rcfreakamit Місяць тому +1

    Nice analysis and presentation, thanks! In case you are still into these studies (or already done it :), it would also be interesting to see a similar set charge charts for multi-cell packs with BMSs, especially, understanding how the different cutoff voltages affect the BMS ability to keep the pack balanced.

  • @catesolarcatamaran252
    @catesolarcatamaran252 3 роки тому +24

    The only advantage to charge with 3.65v is fast charge /I personally set mine to 3.5v and they are stil going strong after 12 years. 😊

    • @SolarEngineering
      @SolarEngineering  3 роки тому +3

      wow, what is the brand of the cells? Did you measure capacity after 12 years?

    • @catesolarcatamaran252
      @catesolarcatamaran252 3 роки тому +1

      @@SolarEngineering they have lost about 20% capacity. Later I will take look for the brand name.

    • @catesolarcatamaran252
      @catesolarcatamaran252 3 роки тому

      The manufacturer number is against the wall and I am not disconnecting and moving it to find it "weighing 120kg". I bought it trough alibaba China

    • @amalhalder2219
      @amalhalder2219 2 роки тому +1

      @@catesolarcatamaran252 can you get the info from other source like order page etc?

    • @amalhalder2219
      @amalhalder2219 2 роки тому +1

      And can you tell us what for these batteries Ar being used? Is it energy storage? How many cycles it do per year?

  • @gojeffgordon24
    @gojeffgordon24 3 роки тому +3

    Another idea, have you thought of trying the same with Li-Ion batteries, NMC ones? Curious to see how 4.0, 4.10 and 4.20 behave. I think it will make a bigger difference there due to the charge/dischange curves. Could try with a couple 18650's in parallel to get an idea with a 10ah or so capacity.

  • @1over137
    @1over137 Рік тому +1

    The charger and discharger are only connected with 2 wires, there is no sense wires, so the test is unfortunately invalid. You simply CANNOT measure voltage on a cable carrying current. It doesn't work. Voltage measurements made on cables while they are carrying current are invalid. Start again.

  • @neliosamch3195
    @neliosamch3195 3 роки тому +3

    It all depends of the age and capacity of the cells. 3.4v is my preferable max voltage.
    With the icharger duo 4010 the energy can be recovered into another cell instead of wasting it into heat and the graph charter including the charging logarithms is included and can be downloaded to a pc for better visual.

  • @offgridd
    @offgridd Рік тому +3

    Nice test and yes, going left or right at both knees definately shortens your battery life AND will not give you more that 5-10% extra capacity.
    Running these cells under high current loads is also dangerous because you will dive deep in both of them with risc of damaging your cells.
    So anything between 2 and 3,4/3,45V will be good enough is my opinion.
    Kudo's for your programming with arduino; I am a bit jaleaus to not have these skills.
    Having the advantages of all these smart and tiny helpers would help me greatly, specially when you want to bottom balance cells and having a cell bouncing back to a higher voltage after stopping discharge it to say 2,6 Volts....

    • @SolarEngineering
      @SolarEngineering  Рік тому +1

      thanks! Arduino is not so complicated, many online step-by-step tutorials.

    • @offgridd
      @offgridd Рік тому

      @@SolarEngineering yeah, but a Salsa (as a metafor) never can be performed as well as by somebody who has dance in it's bones, how hard you practice and try.
      If I would say a wiener waltz, then you probably would apply too 😁😁😁

  • @thedolphin5428
    @thedolphin5428 3 місяці тому

    These test are nowhere near relevant to someone with a 200-500AH battery bank and one or two boat alternators (like me) who likes to charge at 80-200A. YOU are talking about "lithium phosphate cells" No! You are talking about YOUR little 25AH x 3.65V cell.
    As I posted before, your tests are nothing compared to the PhD Lithium chemists building and testing these things for a decade.
    Everyone -- be careful not to extrapolate general principles (how much to charge) from simplistic specific tests like this one video.

  • @thedolphin5428
    @thedolphin5428 10 місяців тому

    How can anyone other than lithium battery manufacturers with PhDs in lithium chemistry and a decade of R&D design and testing possibly say "how long a battery will last?)"?
    Have all the armchair techies commenting here EVER OWNED a lithium battery long enough (say 5 years) to see it fail *compared with* some other one treated differently?
    The ONLY PEOPLE who have the right to comment on battery life are those who have done 1000s of charge and discharge cycles in laboratory conditions.
    So sick of hot air wankers.

  • @orkidorkid
    @orkidorkid 2 роки тому +3

    Great work ! Maybe you should make a video about the Aurdreno and the VA tracker. That would be great !

    • @SolarEngineering
      @SolarEngineering  2 роки тому +2

      Thanks, here is video: ua-cam.com/video/EnlKS4hdwk8/v-deo.html

  • @shakeelhuod6303
    @shakeelhuod6303 2 місяці тому

    Does 57.6 volts refer to the charging speed or the energy storage limit of the battery? If someone sets it to 56 volts instead, will they get the same battery backup as with 57.6 volts?

  • @peterking1134
    @peterking1134 3 роки тому +4

    Thanks for the enlightening presentation!

  • @loganv0410
    @loganv0410 3 роки тому +4

    Fantastic vid! Thanks for the effort and knowledge.
    Please post info or added vid (I'd really like a vid) on the equipment used, especially the Arduino and connected stuff

    • @SolarEngineering
      @SolarEngineering  3 роки тому +4

      Thanks.
      I've added links to Arduino parts. May be will add a video on how to build tracker if more people are interested.

    • @robsouto4998
      @robsouto4998 3 роки тому +1

      @@SolarEngineering +1 for this

    • @mikemorin3131
      @mikemorin3131 3 роки тому +1

      @@SolarEngineering I would like to see a video on how the tracker is assembled my self, Thanks

    • @loganv0410
      @loganv0410 3 роки тому +1

      @@SolarEngineering Thanks for adding the links. I hope you do produce a vid on building the tracker, even a short vid referring us to where you got the idea and parts.

    • @adon8672
      @adon8672 3 роки тому +1

      @@SolarEngineering Please let's have a video on the tracker. Thanks for the efforts.

  • @techmaster_sree
    @techmaster_sree Рік тому +1

    Thanks for the info, its good to know that we are not loosing that much capacity on 3.45V

  • @DangerousFA
    @DangerousFA 22 дні тому

    мабуть 3.5 буде найкраще

  • @RJ-cc1fz
    @RJ-cc1fz 3 роки тому +11

    You got skills! Yes there isn’t much capacity to gain charging the cells to their max voltage. But at the higher cell voltages is where balancing should be done.

    • @frodev728
      @frodev728 3 роки тому +1

      indeed, or just leave enough headroom above the absorption voltage setpoint that balancing isn’t even an issue.

    • @eksine
      @eksine 3 роки тому

      @@frodev728 lifepo4 isn't supposed to have an absorbtion phase

    • @frodev728
      @frodev728 3 роки тому

      @@eksine it’s just a label. Semantics. The absorption phase is used for series-packs of cells to allow the balancer to do it’s thing. Of course single-cells don’t need an absorption phase, per-se.

    • @imho7250
      @imho7250 2 роки тому +2

      @@frodev728, it really has nothing to do with how many cells in series or even parallel. But you’re right that “absorption” is just another name for the CV stage, that tell you even though it at max voltage during charge, its not fully charged, and if you end the charge just when CV (absorption) stage begins, the battery voltage will quickly drop to the voltage corresponding to its SOC, which might be 80% if the CC stage was 0.25C.
      Many reserve the term “Absorption phase” for chemical batteries like Lead Acid that really need to be held at a certain peak voltage to complete a chemical reaction that won’t fully complete at lower voltages. Since lithium batteries are not chemical batteries, they don’t need to be held at a high voltage. You can charge them to 80% each time and it will last longer, but doing that to lead acid will kill it fast.
      But when discussing Lithium cells, especially LiFePO4 with such a flat SOC voltage curve, whether its called CV or absorption is not important but rather the effect of that stage at different peak charge voltages.
      As we know, the intercalation rate during CV/absorption is related to the voltage differential. So using the max voltage that doesn’t immediately damage the cell finishes that stage faster. 3.45v is only 0.15v above the 90% SOC voltage (3.3v) so it will take much longer to get that next 5% than using 3.65v, which is 0.35v higher.
      Armed with this basic foundation, a person can size his battery to match the application and desired life expectancy. If you want it to last 8000 cycles, charge it slow to 70%. No absorption stage because it never reaches CV voltage.
      But if you need something that can capture and store energy from the grid at super duper off peak rates of $0.01/kwh but that only last 3 hours then you need to use CC of 2C and CV of 3.65v before rates go back to $1/kwh. Lol
      However if i know i have 8 hrs to charge, i will set CC to 0.2C with CV of 3.65v so it will will be fully charged but only for 2 hrs.
      It really depends on the application, budget and other factors. Videos like this help you decide what’s best for you.

    • @frodev728
      @frodev728 2 роки тому

      @@imho7250 ok I know all of that and of course it’s true, but my point about absorption phase, admittedly this is a misnomer, is that using the “absorption phase” (constant voltage) to hold the voltage above the “balance start voltage” of the balancer to allow the cells to be put back in balance is a useful and necessary strategy. Doing that is ONLY necessary if you have 2 or more cells in series, because by definition any less than that (namely one cell) will always be “in balance” because it’s the only cell.

  • @skrudzasss
    @skrudzasss 2 місяці тому +1

    +

  • @jahrmichi
    @jahrmichi 3 роки тому +2

    cool test. I am only charging to 3.4V

  • @Tokyo1991.JL1AJE
    @Tokyo1991.JL1AJE 3 місяці тому

    If I understand this correctly, the longer charging time is due to the lower voltage causing a less aggressive charge current as the battery reaches the final voltage, thus the tail current (typically 2-3%) aka the ‘we can stop charging now’ current must be set at a lower percentage (of the initial CC value) in order to achieve near 100% SOC at the lower final voltage?
    It looks like finding a sweet spot between 6-10Hrs for 0.2C is warranted but at a voltage that is high enough to trigger the internal BMS of multicell battery such as a 4 cell 12.8V 100Ah LiFePo4 unit.
    If I’m missing something input would be appreciated!

    • @Tokyo1991.JL1AJE
      @Tokyo1991.JL1AJE 3 місяці тому

      Just realized that tail current sensing for end of charge can be left as it is.
      It’s just going to longer to get there.
      Adjust ‘absorption’ aka CV phase accordingly I would guess.

  • @shakeelhuod6303
    @shakeelhuod6303 2 місяці тому

    Does 3.65 volts mean 100% charge and 3.4 volts will charge the cell to 80%?
    Or are 3.65, 3.5, or 3.4 volts the charging speed of the cell?

    • @SolarEngineering
      @SolarEngineering  2 місяці тому +1

      3.65 full charge, 3.45 ~80%. But LFP charge graph is pretty flat, so 3.45 can be ~70%-85%

  • @AnakinSpain
    @AnakinSpain 7 місяців тому

    Hi, Good job!! I have a LiFePO4 in my motorhome. I need that it charge as soon as possible and that MPPT keeps the battery almost 100% all the time. Then I have: Bulk 14.2v. Absortion: 13.4v Re-bulk: 13.3v Do you think it is correct? Then When I have my motorhome parked It is plugged to 220v Then in that case I only need to maintain battery, so My paramters are 13.4v 13.00v rebulk 12.8v What do you think about that?

  • @immrnoidall
    @immrnoidall 3 роки тому +1

    Help;
    When charging on my large lead acid charger in my UPS inverter/charger, the charger does not recognize charge state and taper the AMPS DOWN as it gets full, like when it is charging the deep cycle lead. With my lifepo4 battery , it just stays charging at 40 amps the whole time. This is a problem because as the cells near full, they start to charge up faster, lose balance and always shut down due to a cell over voltage. Thus never getting a "full " charge .I am lucky to get 60%.. with my solar charge controller and other lead acid chargers I have , it works like a lead acid would and tapers the AMPS DOWN as it gets full. Why?

    • @SolarEngineering
      @SolarEngineering  3 роки тому +1

      Assuming that you did top balanced cells, I would install an active balancer that will prevent BMS from shutting down the pack. Depending on size of your battery pack, I can recommend few different balancers.

  • @sreekumarUSA
    @sreekumarUSA 2 роки тому +1

    041122/0247h PST Thank you for the presentation. I have watched this video long time ago and I'm watching again. I fully support your theory of charging LiFePo4 Battery (Cells) @3.40v~3.50v, which will bring battery charge to 96%.(13.6v~14.2V). I have practiced this for almost 4 years and am very satisfied with the results.
    There's no BULGE no deformation and I don't believe in COMPRESSION. Thank you again. 73s...

    • @dollyone3714
      @dollyone3714 Рік тому

      if i only has old inverter (48v/lead acid-agm) that has Bulk and Float charge,
      can i safely set the bulk voltage at 56V and 55.4V for float voltage to my 16s lifepo4 batteries?

  • @stefanosmania
    @stefanosmania 3 роки тому +1

    thank you. Very usefull video !

  • @AdventureMotoEnduro
    @AdventureMotoEnduro Рік тому

    i have 1 cell of 8 in a 24v pack 280ah cells that will not charge over 3.4 volts so i just made them all stop at 3.45 volts ,

  • @gojeffgordon24
    @gojeffgordon24 3 роки тому +2

    Nice work! I hadn't gone to that level before, but always kept mine at 3.60 or lower. Would be interested in the links for the arduino gear used or a video on it even.

    • @SolarEngineering
      @SolarEngineering  3 роки тому +9

      thanks.
      I've added links to Arduino parts. May be will add a video on how to build tracker if more people are interested.

    • @fezdk
      @fezdk 3 роки тому +1

      @@SolarEngineering Yes, I want to know how to build that tracker too - Does it measure both ways (in/out) - and know the difference? :)

  • @ТотКтоГоворитМногоНеГоворяНиче

    Хеллоу мен. Сэнск фор э гуд ворк энд видео. Кип йор лайк

  • @KoiAquaponics
    @KoiAquaponics Рік тому

    I'm going to tie 18s cells instead of 16s for 48v system. Then I think i can use around 60v to charge it and still get 90% of capacity

  • @Longoni_Massimo
    @Longoni_Massimo 3 місяці тому

    Buongiorno. Ottimo test . Io carico i miei 20 kw 4x5 a 4.41V per cella . Una volta al mese a 4.5 . 2 anni senza problemi.

  • @amazingtechnology1961
    @amazingtechnology1961 5 місяців тому

    Are there any data regarding how much of batter’s life or charge cycles is recovered/saved when we charge to 3.45 vs 3.55 or 3.65

  • @todamnbad
    @todamnbad 2 роки тому +1

    What's your opinion on connecting batteries from different manufacturers with different BMS's in parallel? I have some 12 volt 200AH batteries (100AH cells) 12 volt 300AH batteries (150AH cells) all prismatic type cells and also have some 12 volt 300AH batteries (cylindrical cells), I would like to connect some together to make a bigger bank but I keep getting different opinion on videos

    • @SolarEngineering
      @SolarEngineering  2 роки тому +1

      I personally don't see any problems with connecting different packs into parallel (when packs are not too far in capacity from each other, like 5X diff).
      Would like to hear and discuss what is the potential issues could be.

    • @zoe..d
      @zoe..d Рік тому

      @@SolarEngineering There's no downside to this at all. Has been tested and demonstrated over at Andy's Off Grid Garage channel using "extreme" examples. one tiny cell vs a big battery pack paralleled, they both discharge equally regardless of size. If the large pack uses 10% of it's available capacity, so does the smaller one. doesnt matter if its 1000 mAh alongside a 1000 Ah, the little one will be at 900mAh and the other at 900 Ah after a 10% discharge. :)

    • @SolarEngineering
      @SolarEngineering  Рік тому

      @@zoe..d thanks for the info

  • @davetelling
    @davetelling 11 місяців тому

    I just saw this vid. I'm confused as to why, if you are charging at the same current, it took longer to end up at 3.55V than 3.65 volts? The 3.65 volt graph should show reaching 3.55 volts at some point, and it would have to be less than the time to 3.65 volts.

  • @christopherleubner6633
    @christopherleubner6633 8 місяців тому

    3.55v for the win long term. Beyond this, you start ripping the iron from the phosphate, forming pyrophosphates and decomposing the electrolyte in the process, this does not become a critical issue until you exceed about 3.7V.

  • @shawnd567
    @shawnd567 5 місяців тому

    Damn! Would have loved to see this at 3.5 since we saw that massive charge time increase at 3.45. I would definitely not use 3.45v are itll take an insane amount of time to charge.

  • @moestrei
    @moestrei 11 місяців тому

    I have my solar Mppt controller set to 3.45V boots mode for 2 hours and then float mode on 3.35V. Boosts return is 3.25V. Active JK balancer starting at 3.40V for top balancing. Took quite a while (a week) to initially balance. Seems fine so far.

  • @anterdukar6399
    @anterdukar6399 7 місяців тому

    Блин, у меня из ушей кровь пошла :)))

  • @JustaCuriousity
    @JustaCuriousity Рік тому

    Im new to LifePO4, but really, how many type of it? @Off-grid system Andy has tested it best on 3.45V. Maybe every different brand or class really matters?

  • @JohnUsp
    @JohnUsp Рік тому

    The recommendation is 3.42V, this is the voltage that will better extend the life, also is important a max current of 0.3C (I prefer 0.1C)

  • @bonnenonez4344
    @bonnenonez4344 Рік тому

    Can I build a lifepo4 with different Internal resistance I have 32650 cells. some of the battery higher internal resistance

  • @2flight
    @2flight Місяць тому

    great! Thanks!

  • @hunter8202
    @hunter8202 4 місяці тому

    charger 20 amperes is it normal for battery 24v 100ah or is it very hight amperes

  • @WizzRacing
    @WizzRacing Рік тому

    Why having a quality BMS is important.. You can set the cell charge rate to balance cells...

  • @sfkenergy
    @sfkenergy 2 роки тому +3

    The max charge is not used for charging it is primarily used for cell balancing. Most balancing circuitry on the market is carry over form LI-ION or NMC and LI-POLY which do not have a flat voltage profile like LFP. Because of this the only time they see enough of a difference to beging balancing is when 1 LFP cell is high enough to trigger balancing.
    At 3.45v your effectively full charged, but this voltage is not sufficient for balancing hardware.

  • @zulqurnanmasroor9276
    @zulqurnanmasroor9276 8 місяців тому

    Can you guide what should be the float voltage. If we have to set float voltage. 3.55 would be the bulk voltage

  • @jcolivie
    @jcolivie Рік тому

    could you please provide the circuit used with arduino (and software) to monitor the load? I thank

  • @balicrimechannel8143
    @balicrimechannel8143 2 роки тому +1

    Thanks for doing this test; it answered all the questions I needed to know. Well done!

  • @HellTriX
    @HellTriX 2 роки тому +1

    Been looking for this data tested just like this, thanks!

  • @crealpet972
    @crealpet972 Рік тому +1

    Напряжение имеет смысл в случае лиферов, кмк как однозначный предел. Уменьшать его ниже 3.6В, имеет смысл во всяком случае на этапе буст-зарядки, когда ток максимальный, это в отдельных случаях спасет от опасного разбаланса сборку (если балансир не тянет, перегрев и т.п.) и соотвественно срабатывания защиты BMS. Вполне можно обойтись заниженным напряжением в идеальных условиях, когда солнце грубо говоря 8 часов дает избыточную генерацию в систему. Но если на произвольном объекте полный заряд критически важен, а солнце то и дело скрывается за облаками, пониженное напряжение повредит системе уже потому, что будет исключен максимальный ток заряда в момент пиковой генерации. А тест познавательный, такие-же графики на промышленном тестировщике можно наблюдать.

  • @deezelfairy
    @deezelfairy 2 роки тому +1

    Thanks for answering this question, it seems charging to a lower max voltage appears beneficial the same as Lipo/Li-ion cylindrical cells.
    One of the reasons I like my turnigy reaktor rc chargers - they allow you to change the per cell end voltage in the settings.

  • @MrSummitville
    @MrSummitville 2 роки тому

    But .. who has 10 HOURS to recharge the battery pack?

  • @MotoAlias
    @MotoAlias 3 роки тому +1

    I've got a question... my pack is 24s so charges to like 86.7 or 87 volts and it used to stay at 87 volts. Now as soon as I unplug the charger the voltage begins dropping until it gets to the nominal voltage where it stays and then from there I can use my pack but idk why it's doing this.im losing like half my usable volts

    • @SolarEngineering
      @SolarEngineering  3 роки тому

      LiFePo4 cells will drop voltage after charging to ~3.45-50V per cell, so in your case 82.8V - 84V. But don't worry capacity is still there.

    • @MotoAlias
      @MotoAlias 3 роки тому

      @@SolarEngineering ya but mine seems to drop further than that like to the point that each cell would be at nominal voltage 3.2

    • @SolarEngineering
      @SolarEngineering  3 роки тому

      @@MotoAlias ah, that's not normal. Is that brand new pack? Do you have anything else attached to the pack that could draw energy? How quick is voltage drop?

    • @MotoAlias
      @MotoAlias 3 роки тому

      @@SolarEngineering drops by .1 about every 5 seconds... like when I unplug the charger you can watch it drop .1 till it reaches the cells nominal voltage then stops. I guess it could've had a paristic draw going to my headlight but I've disconnected that and still same problem... the pack isnt new I'm afraid I drained it too low. I had 3 cells that were swollen and I replaced them. But I guess even tho the other cells didnt swell perhaps they're all ruined.

    • @SolarEngineering
      @SolarEngineering  3 роки тому

      @@MotoAlias I'd disassemble the pack (or disconnect cells) and test few cells individually.

  • @Sanwizard1
    @Sanwizard1 3 роки тому +1

    This has been confirmed multiple tests. No need to go very high or very low due to the steep curves after 90%

    • @SolarEngineering
      @SolarEngineering  3 роки тому +2

      well, here is another one ;)

    • @MrSummitville
      @MrSummitville 2 роки тому

      @Sanwizard - But we need to go to a high enough voltage to trigger BMS Cell Balancing ...

    • @dollyone3714
      @dollyone3714 Рік тому +1

      use Active Balancer to assist BMS

    • @rafroessolarpowered81
      @rafroessolarpowered81 Рік тому

      @@MrSummitville Use a Balancer that allows you to to set the start voltage and stop balance voltage.

  • @ioannistziovanis-k9l
    @ioannistziovanis-k9l 8 місяців тому

    i need help please,
    i have 8 lifepo4 cells eve 105ah (my battery is 24v 105ah ) i have a bms , i want to charge to 3.55v per cell, is ok to change the settings only in bms from 3.65v to 3.55v and the sum high protect from 28.8v to 28.4v ?
    thats correct? but my mppt charge controller is on 28.8v , i must change and the charge controller to 28.4v ? or just on bms and is ok?
    please help, thank you very much

    • @SolarEngineering
      @SolarEngineering  8 місяців тому +1

      BMS is a 2nd line of control, MPPT should be 1st, so I'd do 28.4 on MPPT.

  • @PatriotsGunClub
    @PatriotsGunClub Рік тому

    Thank You, VERY helpful and informative.

  • @John-brc20
    @John-brc20 8 місяців тому

    Hello ,and thank you for your video, i have 105ah eve 8 cells,
    So is 24v baterry, what is the best to get charge? I have set on my bms 3.6v per cell, and 28.8v total maximum charge. Is good? Or set at 3.55v?
    Thank you

  • @rOSScOGITANS
    @rOSScOGITANS Рік тому

    finally what voltage do you suggest for 16 cell 280a battery pack for daily home use ? my cells after 3.4 begin to to be not equalized and 5-6 cells go fast to 3.5 , i think it's better to have an absoption around 3.4, correct?

    • @SolarEngineering
      @SolarEngineering  Рік тому +1

      3.45-3.5V per cell, with a 3.4V per cell charger might not go at full power while charging pack (it will reach 3.4 and will float there)

  • @dollyone3714
    @dollyone3714 Рік тому

    if i only has old inverter (48v/lead acid-agm) that has Bulk and Float charge,
    can i safely set the bulk voltage at 56V and 55.4V for float voltage to my 16s lifepo4 batteries?
    or i should change to other voltages?

    • @SolarEngineering
      @SolarEngineering  Рік тому +1

      56V should be good enough for 16S LiFePo4, make sure your BMS has cutoff voltage set at 3.65

  • @ch2o2
    @ch2o2 Рік тому

    nice setting, nice test ...however I just don't get why the charging time with 3,45V compared to 3,65V is increasing (instead of getting less) (almost double) with same charging current ...why that?

    • @SolarEngineering
      @SolarEngineering  Рік тому +2

      probably because charger cannot push same amount of amps as at 3.65V.

  • @peteradshead2383
    @peteradshead2383 2 роки тому

    But most LifePo4 chargers don't work with constant voltage , but they try to push as much current as possible until the voltage hit 3.xx volts per cell , So should take the same time to charge to 3.4 , 3.45 , 3.5 , 3.55 or may be a little shorter ?

    • @MrSummitville
      @MrSummitville 2 роки тому

      But most LiFePo4 charge controllers, start in CC / Bulk mode but then switch to CV / Absorb mode.

  • @jungblud59
    @jungblud59 2 роки тому +4

    WoW! I've never seen such an I depth analysis of the charging/discharging cycle regarding capacity. Kudos to you, this is good stuff! I'm going to lower my charge voltage ti 3.45v. Excellent video! Thanks for sharing.

  • @igorkvachun3572
    @igorkvachun3572 3 роки тому

    Yes Test Akb LiFePo4 👍🔋⚡

  • @edmond2romnos286
    @edmond2romnos286 2 роки тому

    tanx for this video, i set my SCC at 28.2v (thats 3.525 per cell),,

  • @BajanAlan
    @BajanAlan 3 роки тому

    Hi SolarE Off Grid Garage is doing the same sort of testing!

  • @raptorpome2577
    @raptorpome2577 3 роки тому

    What is the make and model of the battery discharger and where can I purchase it from

    • @SolarEngineering
      @SolarEngineering  3 роки тому

      added link to the description, I've got it from Aliexpress

  • @josepeixoto3384
    @josepeixoto3384 2 роки тому

    Nice, but are ALL Lifepo4 chemistries, brands, sizes, etc, the same? i Mean, a 280 Ah will behave the same as this one?

    • @SolarEngineering
      @SolarEngineering  2 роки тому

      It is same for all Lifepo4 chemistry

    • @josepeixoto3384
      @josepeixoto3384 2 роки тому

      @@SolarEngineering Do a Video:
      - ---I hear you, apparently so, but somehow i think that,say, a 30 Ah and a 280 Ah LiFePo4s will have different graphs for voltages and SOCs; i mean,at the mV level, possibly even at the centiVolt?;
      Do a video on that;
      Even from different manufacturers,different materials and chemicals, i see different recommendations.
      ( also i just read that CALB recommends that the very first charge be to 3.80 volts, (then to the 3.65), i wonder why).

  • @phamquanghung8603
    @phamquanghung8603 Рік тому

    like 👍

  • @TheFlashmark
    @TheFlashmark Рік тому

    My LifePO4 cells can not hold 3.35V discharging immediately to 3.3 level. Also not charging above 3.35 (53.6V) level. I think the DOD of my cells 80%. Anyone know reason for this?

    • @SolarEngineering
      @SolarEngineering  Рік тому

      are you sure that cells fully charged? Did you try to charge cells to 3.65V?

    • @TheFlashmark
      @TheFlashmark Рік тому

      @@SolarEngineering When top balancing yes. I charged all cells to 3.65. But now cells won't charge after reaching 3.35V (53.6V)

    • @SolarEngineering
      @SolarEngineering  Рік тому

      hm, not sure why it's happening.

  • @mannyfragoza9652
    @mannyfragoza9652 Рік тому

    my Batteries are 70 Ah each doesnt that change the results you have here?

    • @SolarEngineering
      @SolarEngineering  Рік тому +1

      going to be the same results for LFP for any capacity.

    • @mannyfragoza9652
      @mannyfragoza9652 Рік тому

      @@SolarEngineeringThank you that helps me tremendously

  • @robertmarkham6558
    @robertmarkham6558 2 роки тому

    Does it not mean that over time the voltage gap between the cells will drift more as there not hitting max voltage for the BMS to balance them?
    Also when there discharged if there is a big difference then won't the lowest one be below minimum voltage?

    • @SolarEngineering
      @SolarEngineering  2 роки тому

      Good question, at 3.5V per cell v diff will show up, so BMS will have a chance to balance cells. Didn't get about low voltage (BMS will disconnect pack if any cell drop below preset voltage)

    • @dollyone3714
      @dollyone3714 Рік тому +1

      i would rather use Active Balancer to help BMS on balancing task.

  • @americannumber2
    @americannumber2 Рік тому

    Count amps in

  • @wizdumb420
    @wizdumb420 2 роки тому

    Curious, what dll did you use for the INA260, the adafruit or some other ? I have had mixed results with the INA units.

    • @SolarEngineering
      @SolarEngineering  2 роки тому +1

      here is video where I'm building tester: ua-cam.com/video/EnlKS4hdwk8/v-deo.html

    • @wizdumb420
      @wizdumb420 2 роки тому

      @@SolarEngineering I found it. thank you.

  • @Каксваритьпельмени-ы4ч

    Would be also nice to know the minimum voltage and if there is any sense to go below 2.6v

    • @SolarEngineering
      @SolarEngineering  Рік тому +1

      at 2.9 battery is fully drained, there may be just a few percent of capacity.

    • @FutureSystem738
      @FutureSystem738 Рік тому

      @@SolarEngineering I don’t go below 3v ever. The tiny bit of extra capacity is not worth the extra stress on the battery.

  • @edmondromanos9256
    @edmondromanos9256 2 роки тому

    helps a lot, thanks bro,,

  • @objection_your_honor
    @objection_your_honor Рік тому

    👍

  • @mikeb6389
    @mikeb6389 3 роки тому

    Thanks

  • @ambientfish1369
    @ambientfish1369 3 роки тому +1

    Hi, I have 8 Pylontech LiFePO4 48v 50ah (2.4kWh) batteries with the charge voltage set at 53.3 volts in the inverter/charger settings. Assuming these are 15 cell batteries this gives a charge voltage of 3.55 volts per cell, would you consider this the optimum charge voltage for battery longevity verses charge times. This is the settings set by the system installer 3 years age, If I understood your excellent video correctly a lower cell charge voltage of say 3.50 volts takes longer but extends cell lifespan, i'd drop the cell voltage as for 80% of the year the battery is fully charged by midday and for the other 20% I top up the battery during the night on cheap rate grid power. Thanks in advance for any advice.

    • @SolarEngineering
      @SolarEngineering  3 роки тому +2

      Hi, I'd double-check how many cells are there (15 or 16). Also based on my tests I would recommend lower voltage to 3,5V per cell. You'll still get the same charging speed and capacity, but the "safety" range will be a little bit more bigger.

    • @ambientfish1369
      @ambientfish1369 3 роки тому +1

      @@SolarEngineering Hi thanks for your reply, I just checked, they are 15 cell batteries. So following your advice I should reduce the maximum charge voltage to 52.5 volts for added protection/safety of the modules, i've tried to prolong the battery lifespan by never discharging below 40% SOC, rarely below 60% SOC in daily use, am I helping doing this? There seem to be a consensus around this practice of limiting DOD to extend battery life so i'd be interested to have your take on this. Once again thank you for any views and information you provide.🙂👍👍👍

    • @SolarEngineering
      @SolarEngineering  3 роки тому +2

      @@ambientfish1369 52.5 sounds right then. I think 40% SOC is too generous for LiFePo4, you could use 80% of it's capacity and it's considered as light use, also important C rating you charge and discharge (smaller rating = longer life).
      (My statement about 80% is based on information I read on multiple resources, I didn't test it since it's taking years).

    • @ambientfish1369
      @ambientfish1369 3 роки тому +2

      @@SolarEngineering Thank you bro for the replies I really appreciate your valuable time. I do try to restrict the draw from the modules, most of the day the house is using solar power direct from the panels, at night average draw from the battery is 220 w at circa 4-5 amps with an very occaisional 2000w draw of short duration for the oven (20 mins) max, I know it is worth being careful in how you utilise batteries and I want them to last as long as possible, thank you again you have been a big help🙂👍👍👍🏴󠁧󠁢󠁳󠁣󠁴󠁿

    • @ambientfish1369
      @ambientfish1369 3 роки тому +1

      I've just set the charge voltage to 52.50 volts, thank you.

  • @MiranPayman
    @MiranPayman 2 роки тому

    I have 48v life po 4 cells I found that charging at 53.7v for 82-88% capacity and cut off voltage of 49v which is 3.065 is best long term cycle life.

    • @aaaaaaaaaa5446
      @aaaaaaaaaa5446 2 роки тому

      what links do you have. you can provide a link

    • @freetrailer4poor
      @freetrailer4poor 2 роки тому

      53.7 is 3.356 or 13.425 12v and 26.85. 3.065 is 12.26

    • @MrSummitville
      @MrSummitville 2 роки тому

      @Meran - How do you KNOW that your theory "... BEST for long term cycle life ..." ?

    • @MiranPayman
      @MiranPayman 2 роки тому

      @@MrSummitville its lithium so better not discharge to 0% nor always be at 100% high voltage

    • @MiranPayman
      @MiranPayman 2 роки тому

      @@freetrailer4poor I actually lowered the charging voltage to 53.4

  • @simpletennesseelife5895
    @simpletennesseelife5895 3 роки тому

    Amazing info!

  • @olgglo
    @olgglo Рік тому

    спасибо! относительно недавно интересуюсь этой областью, ищу все, что можно посмотреть по этой теме, отличный видос! судя по акценту, переводчик для камента не понадобится )

  • @thatguysayz
    @thatguysayz 2 роки тому

    Good info, thank you