ERROR E2 in CLBIO controllers, discover the most common cause and how to solve it. Pellet load.

Поділитися
Вставка
  • Опубліковано 8 сер 2024
  • Discover one of the most common causes that cause this ERROR E2 so mentioned and that brings many users of pellet cookers, NEMMAX, DOKII, Extraflame, Albin Trotter, IFLAME and many others that are equipped with CLBIO controllers.
    By manual they describe 4 possible causes and all of them are valid, but really in many cases this ERROR E2 is unknown that one of the most common causes is the deficient load of pellets in the ignition cycle of the cooker.
    Yes friends, really the community of BIOMASS FOR ALL works, and the comments that you leave us here under each video we publish and the amount of messages you send us through our website, helps us to detect and correct in many aspects problems that have easy solutions, and many of them without spending a single Euro in spare parts or costly repairs.
    That is why we continue to publish and spread the message of BIOMASS FOR EVERYONE, as a change and we are proud that this family continues to grow, and among all promote the knowledge and operation of pellet cookers and the most typical parameter errors.
    It is important to know each of the MISTAKES in pellet cookers and what are their possible causes.
    That is why from BIOMASS FOR EVERYONE we always advise you to read the contents of the pellet cooker manuals, to know the correct operation of a pellet cooker, possible errors and how to solve them.
    If for any reason you do not have the original manual, we have great news for all of you and that is that from January 2023, we are launching a new download section on our website.
    There you can download a huge amount of user manuals for many brands of pellet cookers and we continue to add week after week.
    In addition to downloading pellet cooker parameters of the most famous controllers and used in the industry of domestic and industrial pellet cookers.
    But back to the subject of ERROR E2 and pellet underloading, it is important that you watch this video and you can solve yourselves this error that brings so many people upside down with their pellet cookers.
    Simply enter the user menu of your cooker and go to parameter 7 and check the current values.
    Once you have checked this you should apply the correction according to the height of the orifice of your pellet burner and always be at least 1 centimetre above this.
    The process can be done gradually and in several ignition cycles of the cooker, you will get a correct calibration and without errors in the ignition of pellet cookers.
    ERROR MESSAGES:
    Error E1
    This error is due to the flue gas temperature being below 40-45°, the probable causes of which are as follows:
    1. Not enough pellet.
    2. The worm motor is faulty and does not feed the cooker.
    Error E2
    This error is due to a misfire at start-up. Probable causes may be:
    1. The burner is dirty or has hard residue on it.
    2. The ashtray has not been correctly installed.
    3. The flue gas temperature sensor on the combustion fan is faulty.
    4. The ignition resistor is faulty.
    Error E3
    Means that there has been a sudden movement of the cooker during operation or the cooker has tilted. This error code is mainly programmed for earthquake zones.
    Error E4
    Problems with the temperature sensor.
    Means that the high temperature sensor is faulty.
    The temperature is so high that the cooker does not work properly.
    Error E5
    It means that there are some problems with vacuum switch. Such as the door has not closed properly.
    The combustion fan speed cannot accelerate.
    There is some leakage around the cooker or the flue pipe is blocked.
    Error E6
    It means that the high temperature sensor under the hopper has some problem, such as:
    1 . The switch is broken,
    2. The temperature is too high and causes the cooker to shut down.
    Error E7
    During operation the cooker has stopped due to a power failure.
    Don't miss this interesting video which is claimed by many people and of which we will make a series.
    Don't miss the next video next week...
    We will talk about "The secrets of easy access".
    If you like the information and videos with your simple subscription and alert in the notifications you help us a lot to continue creating quality content.
    SUBSCRIBE: / biomasapara. .
    www.biomasaparatodos.com
    We hope to see you often on the channel and count on your comments to stay in touch and generate great feedback for the entire community.
    We believe in change, we are committed to the environment, we make biomass a way of life.
  • Наука та технологія

КОМЕНТАРІ • 15

  • @smk7575
    @smk7575 6 місяців тому

    Hola, muy buena explicación. Gracias.

  • @erwinmunoz9687
    @erwinmunoz9687 Рік тому +1

    ERES GRANDE MASTER👍👍
    EXCELENTE EXPLICACION

  • @leonardosepulveda8166
    @leonardosepulveda8166 Рік тому

    Hola biomasa un saludo desde Temuco, ciudad de Chile, primero felicitarte por tu programa.Quiero saber si puedes darme parametros para una estufa marca Alkazar P1800.desde ya gracias

  • @alfredojimenez4936
    @alfredojimenez4936 Рік тому +1

    Hola saludos, es posible saber como eliminar las horas de servicio de esa estufa?

  • @sergiotricas771
    @sergiotricas771 Рік тому

    Hola buenos días , a mi me da e2 pero lo estoy intentando arreglar y no puedo, sabes si hay algún servicio tecnico de estas calderas o puedo contactar contigo para que me puedas ayudar... Gracias

  • @VICTORSALAZAR-nb6wv
    @VICTORSALAZAR-nb6wv Рік тому

    me podria decir si esta estufa necesita borrar horas de servicio?

  • @anaromero5155
    @anaromero5155 Рік тому

    Hola cómo puedo saber si la bujía es de cerámica o no de mi estufa a pellet ecopelet 360-3?

  • @jorjepissarra6491
    @jorjepissarra6491 Рік тому

    Boas tardes eu tenho uma maquina da marca Delba de 13 kw e tem o mesmo displei não pode enviar os dados completos do menu oculto pois gasta muitos peletes e o vidro fica preto passados 15 minutos fico a aguardar resposta obrigado

  • @jorjepissarra6491
    @jorjepissarra6491 Рік тому

    Boas noites pode enviar-me os parâmetros para uma máquina da marca Delba de 13 kw gasta muitas peletes o vidro fica preto passado 30 minutos tenho visto os seus vídeos e não vi as da minha máquina obrigado e fico à espera de uma resposta OBRIGADO

  • @miguelangel15715
    @miguelangel15715 6 місяців тому

    Hola en mi display me sale ESo3. A qué se debe y cómo puedo eliminarlo?

  • @forxan
    @forxan 6 місяців тому

    Hola,
    Estoy buscando el manual de instrucciones de la estufa de pellets "EQUATION EQ 8" y no lo encuentro.
    Sí alguien lo tiene se lo agradecería.
    Un saludo

  • @angelrecalde6354
    @angelrecalde6354 Рік тому +1

    Yo tengo el error E1, después de tener en funcionamiento la máquina, cuando estabiliza, le cuesta bastante; luego pasa a ECO2 y baja la llama , se pone en enfriamiento y se para.
    Que me puedes decir?
    Gracias
    No puedo acceder a la posición 8 que es: CLEANING
    Tengo una estufa iflame 8
    Tampoco puedo acceder a la clave 1088
    Como se accede a punto 8 del menú.
    Gracias

    • @Biomasaparatodos
      @Biomasaparatodos  Рік тому +1

      Que le está faltando carga de pellets en la potencia 4. Que justamente es ECO2 cuando modula. Deberias subir algo la alimentación de la potencia.
      Mira bien cuanto tiempo tienes ahora de:
      Last:
      Every:
      Intenta subir last 1 segundo mas y vas probando pero no pases de 3 o 4.
      Si ves que con eso no funciona debes ir reduciendo EVERY.
      Por ejemplo:
      Si ahora tienes esta configuración:
      LAST 2. EVERY 8.
      Pues tu pones:
      LAST: 3. EVERY 8
      LAST : 4. EVERY 8
      Vas probando con las dos opciones y vamos vamos viendo si aguanta.
      Sino debes bajar EVERY TAL COMO EL EJEMPLO.
      LAST 4 EVERY 6
      No quiere decir que estos sean los valores correctos. SON A MODO EJEMPLO.
      Primero debes entrar en el menú técnico con tu clave y acceder a los parámetros de la potencia 4.
      No estaría de mas que copies todos todos todos los parámetros de la estufa en una libreta.
      Bien apuntados.
      Después si puedes tocar y modificar ANTES NOOOOO.
      La estufa se pone en enfriamiento y se apaga con error E1 por falta de alimentación de combustible y porque la temperatura de la cámara de combustión desciende por debajo de los 60 grados.
      La tienes en modo ECO ECOLOGISTA Y ECONOMMISTA. Hahahaha.
      Una pequeña broma pero que tiene siempre solución.
      Ve probando y nos dices.
      Aquí estamos.
      Que tengas un buen año y queremos leer tus comentarios con una copa brinndando con tu familia y calentitos todos con esa estufa.
      Biomasa para todos les desea un feliz 2023.

    • @felipemunoz3350
      @felipemunoz3350 Рік тому

      @@Biomasaparatodos Gracias.