Slow Speed Bearing Monitoring with Vibration Analysis and Peakvue

Поділитися
Вставка
  • Опубліковано 12 лют 2016
  • Vibration Analysis with Emersons Patented PeakView enveloping is very useful for detecting slow speed bearings down to 1 rpm. Here is an example of a 20 rpm roll needing condition monitoring and what you see from the live results and stored data
  • Наука та технологія

КОМЕНТАРІ • 10

  • @muhammadtrendo2517
    @muhammadtrendo2517 4 роки тому

    Can we set band pass peakvue setting, e.g 100-500Hz?. Sometime i see nothing in peakvue (HP 500) for low speed (30rpm), in actual condition bearing has defect

    • @Pdm-reliability
      @Pdm-reliability  4 роки тому

      Never tried that band pass. I had one bearing recently that had a fault that was not giving any signal, It had failed sometime ago and running on the housing and it was regularly greased,so it was acting like a sleave bearing. Out off 400 bearings, I find the settings I use gives me 99+% capture, but there is alway one that will behave differently

    • @muhammadtrendo2517
      @muhammadtrendo2517 4 роки тому

      @@Pdm-reliability Thank you. One more question, in low speed beraring defect case, what do we need to see to justify the correct execution time? Time waveform Pk-pk g?

    • @Pdm-reliability
      @Pdm-reliability  4 роки тому

      @@muhammadtrendo2517 Hi Muhammed. I usually monitor at 0.5gs peakvue and repair above 2.5gs peakvue. I have seen bearings go upto 90gs as they are chewing up the balls if the customer cant repair quickly.

  • @fredya3416
    @fredya3416 5 років тому

    What are the parameter you used to set up peakvue ?

    • @Pdm-reliability
      @Pdm-reliability  5 років тому

      Hi Fredy A. I used 80 hz FMax, with 500 hz Highpass Filter and 1600 LOR, 1 Average, if that makes sense

  • @fahadqureshi9713
    @fahadqureshi9713 Рік тому

    What is the specification of the sensor used?

    • @Pdm-reliability
      @Pdm-reliability  Рік тому

      100mv/g accelerometer. Ctc brand

    • @fahadqureshi9713
      @fahadqureshi9713 Рік тому

      @@Pdm-reliability model of sensor?
      Frequency range? Does it work with CSI 2140 analyzer?

    • @Pdm-reliability
      @Pdm-reliability  Рік тому

      I use the CTC Ac 203 sensor for slow speed on my 2140