How To Connect A Generator To Your House | Step-By-Step Tutorial

Поділитися
Вставка
  • Опубліковано 22 січ 2025

КОМЕНТАРІ • 16

  • @leeskipper7041
    @leeskipper7041 2 місяці тому +1

    Good video

    • @ben_chill
      @ben_chill  2 місяці тому

      Thanks for watching!

  • @keiththompson2289
    @keiththompson2289 2 місяці тому +1

    What kind of cord do you need to go from the generator to the outlet box? Great video by the way !

    • @ben_chill
      @ben_chill  2 місяці тому

      Hi Keith, you'll need a 30amp NEMA L14-30P/L14-30R. This is the one I use in the video amzn.to/496EX6U

  • @VoteDaveThomasMO36
    @VoteDaveThomasMO36 12 годин тому +1

    The interlock screws look improperly set. There is no room on the oval screw openings, to slide the main breaker back to ON position. It looks like you can turn off the gen breaker, just fine, but both breakers would then be OFF.
    You probably discovered that after the test, right?

    • @ben_chill
      @ben_chill  11 годин тому

      You are correct, I had to go back and make a slight adjustment. Measure twice and drill once 😂

  • @dr.sparky3728
    @dr.sparky3728 2 місяці тому +2

    Where's your NM box connector on your 10/3?

    • @ben_chill
      @ben_chill  2 місяці тому +1

      Great question! I know I showed the connectors in the beginning, but as I was working through my particular install, I ended up not using them. The outlet box I purchased has the built in rubber grommets where the wire goes through and that was enough to not only hold the wires in place, but assure that they don't rub against the metal box. On the panel side, the metal punch hole was about an inch, inch and a half and the hole that I drilled out through the stud was only 1/2", so again, no possible way to add one and no possibility of rubbing either. I should have pointed that out better.
      But you're 100% correct pointing that out. If the wire has any chance of rubbing metal going through either the outlet box or the panel, the connector should definitely be used.

    • @unclev7075
      @unclev7075 2 місяці тому +1

      Interlock is not allowed here in Canada.

    • @ben_chill
      @ben_chill  2 місяці тому

      @@unclev7075 really? That's interesting because it's a huge safety concern NOT having one installed.

    • @unclev7075
      @unclev7075 2 місяці тому +1

      @ben_chill not allowed to install using the interlock method by canadian code. Must use a generator panel or add a secondary panel.

    • @keiththompson2289
      @keiththompson2289 2 місяці тому +1

      @@ben_chill What is a "NM box connector?"

  • @StevePenman-p7f
    @StevePenman-p7f 2 місяці тому +1

    Generator bonded or floating?

    • @blainecelestaine4543
      @blainecelestaine4543 Місяць тому

      If you use a portable generator it is recommended to disabled the ground neutral bond in the generator , usually by adding a switch so you can use it both ways.