Snibe MAGLUMI 800 -- Fully Automatic Chemiluminescence Immunoassay (CLIA) System
Вставка
- Опубліковано 7 лют 2025
- Snibe MAGLUMI 800 -- Fully Automatic Chemiluminescence Immunoassay (CLIA) System
𝐏𝐫𝐨𝐝𝐮𝐜𝐭 𝐇𝐢𝐠𝐡𝐥𝐢𝐠𝐡𝐭𝐬
🌟𝐏𝐫𝐢𝐧𝐜𝐢𝐩𝐥𝐞 𝐨𝐟 𝐋𝐮𝐦𝐢𝐧𝐞𝐬𝐜𝐞𝐧𝐜𝐞
•Non-enzyme involved flash chemiluminescence, long stability of reagents
•ABEI label, stable in acid and alkaline solution
🌟𝐌𝐚𝐢𝐧 𝐅𝐞𝐚𝐭𝐮𝐫𝐞𝐬
•Throughput: up to 180 tests/hour
•24 hours ready to use
•Time to first result:17 minutes
🌟𝐌𝐨𝐝𝐞𝐬 𝐨𝐟 𝐎𝐩𝐞𝐫𝐚𝐭𝐢𝐨𝐧
•Random, Batch and STAT
🌟𝐒𝐚𝐦𝐩𝐥𝐞 𝐋𝐨𝐚𝐝𝐢𝐧𝐠
• Up to 40 sample tubes
• Continuous loading, STAT available
• Analyzer auto numbered
• LIS connection
• Refrigerated sample area with independent power supply
🌟𝐑𝐞𝐚𝐠𝐞𝐧𝐭 𝐋𝐨𝐚𝐝𝐢𝐧𝐠
•9 reagents on board
•Continuous loading
•RFID reading all info of reagents
•Refrigerated reagent area
🌟𝐑𝐞𝐚𝐠𝐞𝐧𝐭 𝐅𝐞𝐚𝐭𝐮𝐫𝐞𝐬
•Integrated kit, ready-to-use, no pretreatment required
•Integrated kit including calibrators
•Using superparamagnetic microbeads
•RFID tag storing all info of reagent
•RFID tag with built-in master curve
•2-point calibration to adjust master curve
•Calibration stability: Max 4 weeks
🌟𝐎𝐭𝐡𝐞𝐫 𝐅𝐞𝐚𝐭𝐮𝐫𝐞𝐬
•Clot detection
•Liquid level detection for reagent
•Optional ratio for sample dilution
•Auto dilution for high concentration sample
•Constant 37℃ incubation
•15-30℃ Operating Temperature
𝐎𝐩𝐞𝐫𝐚𝐭𝐢𝐨𝐧 𝐒𝐲𝐬𝐭𝐞𝐦
•Windows 7
•HP compatible (Dual-core CPU), Color touch screen
𝐈𝐧𝐭𝐞𝐫𝐜𝐨𝐧𝐧𝐞𝐜𝐭𝐢𝐨𝐧
•Connection to LIS via COM or network card
•Direct operation on LIS system to test
𝐃𝐢𝐦𝐞𝐧𝐬𝐢𝐨𝐧𝐬 𝐖𝐞𝐢𝐠𝐡𝐭
•102x72x56cm, 73Kg
------------------------------------------------------------------------------------------------------------------------------
𝐅𝐨𝐫 𝐦𝐨𝐫𝐞 𝐝𝐞𝐭𝐚𝐢𝐥𝐬, 𝐰𝐞𝐥𝐜𝐨𝐦𝐞 𝐭𝐨 𝐯𝐢𝐬𝐢𝐭 𝐮𝐬:
𝐖𝐞𝐛𝐬𝐢𝐭𝐞:
👉 www.snibe.com/en/
𝐋𝐢𝐧𝐤𝐞𝐝𝐈𝐧:
👉 / posts
𝐅𝐚𝐜𝐞𝐛𝐨𝐨𝐤:
👉 / snibepage
𝐈𝐧𝐬𝐭𝐚𝐠𝐫𝐚𝐦:
👉 / snibe_global
One of the best CLIA system
Yes
Thank you sir
Looks very similiar to Liaison
Tempreture sample erea is out of limit help me engineir
Sample arm not working solution?
the assay method of Anti HBe has been changed, please reload kit after measurement has finished
How do I resolve this
Good technology. However, Equipment error rate (breakdown) is so high. Even simple errors may require a technician that frustrates the user.
Mr Emmanuel according to you what could be the causes of the errors you encountered?\
and have you done some QC on such test i mean using different machine or from different lab
That y you can't be using it and be focussing on other test , it needs attention, I used maglumi 600
Good
Biossays 240 plus - LIS mode is TCP/IP or RS232? And which standard used - ASTM or HL7?
how the diference syphilis test use maglumi...and TPHA test
Please disscuse all the error
Calibration
commentez nous en francais