5.8 Manual of PCI - How to manipulate catheters to engage via radial access

Поділитися
Вставка
  • Опубліковано 20 гру 2024

КОМЕНТАРІ • 8

  • @denizaktürk-j7n
    @denizaktürk-j7n 4 роки тому +3

    These videos. 5.1 to 5.8 must be watched by all cardiology fellows. Hope the rest comes. This serie of videos is very educative. This is an invaluable experience sharing.

  • @matheuscsmed
    @matheuscsmed Рік тому

    Thank you, Matheus Silva

  • @shangz0216
    @shangz0216 4 роки тому +2

    Thanks for your sharing.

  • @sathishkumar-qs3ce
    @sathishkumar-qs3ce 4 роки тому

    Very useful.. request u post videos on how to handle amplatz catheter...

  • @onlyredpoppy
    @onlyredpoppy 4 роки тому +1

    God bless you

  • @shaveenvijayan8423
    @shaveenvijayan8423 3 роки тому

    Sir, if the catheter folds on itself, shouldnt we downsize it, rather than upsizing it?

    • @manosbrilakis
      @manosbrilakis  3 роки тому +4

      It is actually the opposite - catheter bending on itself means that it is too small for the size of the aorta. A large catheter (upsizing) would, therefore, be needed to prevent folding on itself.

  • @morikanteyekeyeke6147
    @morikanteyekeyeke6147 4 роки тому

    Interesting,