SOLAX 6KW WITH 12 SOLAR 585W
Вставка
- Опубліковано 8 лип 2024
- 📲03433477786 Only Serious Buyers May Contact
#agradesolar #electrical #solarsolutions #homeenergystorage #electrician #solarpower #homeenergysystem #lithium #solax #solax6kw #solaxpower
#agradesolar #solarsolutions #electrical #batteryless #solarpower #withoutbattery #solax #solax6kw #SolaxLowVoltage #solaxpower #SolaxHybridInverter
#SolaXCase
#SolaX
#X3-ULTRA
#X-IES
#X1-HYBRID LV,
#X1-Lite LV,
#X3-NEO LV
#SolaXPower
#renewableenergy #solarenergy #solarinverter #hybridinverter #energystorage - Наука та технологія
Nice video my friend ❤💚❤💚❤💚❤
A very creative idea ❤💚❤💚❤💚❤
I look forward to seeing your designs. Congratulations on your journey forward
زبردست
Good
Brother can you please guide me ... Should I buy inverex Veyron II 6kw or Solax 6kw ip65... Please reply kar den... Bari confusion hai
Sir nitrox 8kw ke sath kitne pannels laga sakhte hai
Ek question ha aap say yeh wala system monthly kitnay units produce karay ga ?
Looking forward for your answer
❤❤
❤
brother mar solex 2.7 apmer lata ha jb on karta ho kiya waja ha apka dakha ha 0.8 amper lay raha ha
Sir gridy on ya off hony par ye output cut krta ha Koi solution btain???
Nitrox 8kw ki mppt volt range to 425 hai
Or 10 10 pannels ki string to 470 volt bana rahe hai es se inventer ko koyi fault to nhi hoga
Bhai yh inverter thk h.
I like your work. Kash ap Faisalabad mein service provide kry
Thank you for Appreciation - Brother Currently it's impossible for us to Work in Punjab.
Rates bata dia Karen plz ❤
Running into huge issue, pls advise. I put heavy load on GEN port and light on EPS. I don’t want to run heavy load on batteries. So in smart load option in battery voltage OFF eg I set it to 50V, and when battery discharges to OFF value then both GEN port and EPS goes off so entire Solax inverter shuts down no output… how to run GEN/heavy load on PV only in Solax and it should not run on battery??
As long as the system has Grid power, Heavy Load will also catch BASIC programming if you have SBU mode enabled. Meanwhile, if the grid goes out, the Directly Smart Load setting will apply and the battery will not discharge. A lithium battery has a heavy load cut-down automatically after 20 percent battery usage.
@@AGradeSolarKarachi Brother I am using tubular lead acid battery and SUB mode. When grid goes off and there is no PV, how do I ensure Heavy load does not run on battery?
Why u r not using SPD for surge protection? Is it save to run inverter without Spd
Ground Earth is Very Necessary for SPD Protection and Unfortunately Homes Don't Have Ground Earth
Brother mery pas Exide TR 1500 145 amper ki 48 volt ka system hai or tubular battery hai us k bulk change voltage or folting voltage ketny rahkny hai plz reply
Bluk 57.6
Float 56.6
Sir Solax IP-65 kesa inverter hai? Nitrox Kay equal hai?
Sir Equal Nehin Keh Sekte but It's Good Competitor in Low Price
Salam Bhai
I like your work, i want to know Which one is better in 6kw and 10kw Solax or Knox?
Plz guide
Regards
Sir Both are Good in their Own Capacity - No Comparison due to Price Difference
Ya phr NitroX best h??
Aoa, sir ma lahor sy ap k projects bohat achy or informative hoty hain ma ap ki videos bohat shoq sy dekhta hun tu ma ny solax power 6kw install kiya hy is ma aps load ka means light load hy gen load ka means heavy load out put hy kindly tell me confirm this confusion ok reply plz
Can we run solax power 6kw with 16 pannels (580 each) easily??
Yes 💯 Without any Tension
Bhai jan, price tu batao
Sit total cost bhi is setup ki bataya karain
Approx Ten Lac + Fifty to Seventy Thousand 1050000
Inverex is one the best invertor...
But same price ip21
And this one is ip65
Still my opinion is inverex bcz we use from many years inverex and trusted
Sir It Depends upon your Choice that Which Brand you want to go with
Apke ps Inverex kabsy work krha hai?
Solax 6KW ki price kya hai.
268
Bhai I installed 6kw solax hybrid inverter but now electric meter reverse light on how can I solve this problem
Ct need to install
Ayp ka koi electrical component issue Ker reha hai get checked your pannel box by closing breakers one by one - if other things are properly installed
@@KashifAli-np3pw ct installed
@@yasirhabib3839 check properly
Wtsap nambar