4100 MP-AES Demo

Поділитися
Вставка
  • Опубліковано 20 чер 2024
  • The Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer (MP-AES) doesn't just redefine a category -- it creates a new one.
    Say goodbye to flammable and expensive gases. Say hello to enhanced productivity. The Agilent 4100 MP-AES runs entirely on air. It's safer and more cost efficient. It enables superior detection and unattended multi-element analysis. Watch this web demo video to see the Agilent 4100 MP-AES in action.
    More information at www.agilent.com/en-us/products...
  • Наука та технологія

КОМЕНТАРІ • 20

  • @dannynguyen2382
    @dannynguyen2382 4 місяці тому +9

    We gettin outta Pimentel with this one 🔥🔥🔥

    • @fastpony7025
      @fastpony7025 4 місяці тому +3

      And straight into Latimer.

  • @arjungarapaty7208
    @arjungarapaty7208 2 роки тому +33

    POV: you're in Chem 4B at Berkeley

  • @onyangoleon7556
    @onyangoleon7556 3 роки тому +2

    That is a very perfect demonstration on the instrument.

  • @pearlngobeni7214
    @pearlngobeni7214 5 років тому

    This is really good,even though you didnt show sample introduction

  • @algiskara
    @algiskara 4 роки тому

    Can be MP-AES technology used in mineralogy, especially interest of rare earth elements, such as lanthanides and actinides? Do you have an experience with spectrum generated by lanthanides and actinides?

  • @MrChivun
    @MrChivun 4 роки тому +2

    Can MP-AES measure multiple wavelengths ( Multiple Metals) on same run ? If so, how many wavelengths (metals) can it measure on single run ?

    • @TheValkyrie100
      @TheValkyrie100 2 роки тому

      it can measure almost any element from periodic table as long as you calibrated your instrument for them (i.e. introduce standards first). But based on expierence, I can say that better not analyse all elements at the same time to avoid scatter. Better choose elements with close wavelenths and group them. Like in periodic table (groups 1, 2), halogens, group 2-3 elements etc.

  • @obedibrahim8177
    @obedibrahim8177 Рік тому

    Hello Mr Steve, I'm Obed from Nigeria. Please what can one do if the microwave plasma atomic emission spectrometer refuses to ignite. Tnx

  • @rajnivisvakarma3934
    @rajnivisvakarma3934 5 років тому

    pls tell us how to create Microplasma in MP AES

    • @jplener1005
      @jplener1005 5 років тому +1

      Dear Rajni, unlike previous MP sources, MP-AES couples energy from electromagnetic Field as seen in the video. An electrical field is used to concentrate axial magnetic field around the torch. The torch design is similar to the one used in ICP techniques, so this create a toroidal plasma that allows introduction of aerosol samples by using also a classical nebulizer-spraychamber. In this instrument, we use Nitrogen as plasma gas and plasma works at atmospheric pressure. You can learn more on the technology, waveguide and cavity design by reading some scientific publications (I can provide details). Just let me know if you need more specific information not sure I answered correctly your question. Kind regards. Jean-Pierre Lener, Agilent Technologies

  • @onyangoleon7556
    @onyangoleon7556 3 роки тому +1

    Which gas does the instrument use for the analysis?

    • @somarpr
      @somarpr 3 роки тому

      Nitrogen from a Nitrogen generator. You supply air to it from a very clean and dry compressor.

  • @davidjiang1437
    @davidjiang1437 6 років тому

    Why role does nitrogen play in this process?

    • @niklasstix5548
      @niklasstix5548 6 років тому

      The nitrogen gas makes up the plasma