If the water pressure is low then remove the spring from the value and then install it to the geyser.... Do not operate without safety value.... I'm going to do the same at my home...
Bathroom renovation k time geasure utara tha , wapas lagaya to ab valve on krte hi safety valve se paani aata h bht tez! Valve band krne k baad b paani aata rhta h 5 min , kya solution h?
@@tech.Appliancesold Bajaj geyser (Shakti plus 15 litre). Ek din Maine geyser off nhi Kiya tha, woh cut off ho gya tha ..next day se Pani Kum aane lag gya outlet se. Kya dikkat ho skti
sir g screw ko kitna tight ya loose m adjust kare ? plz reply🙏🏼 kiyonki mne usko screw drive se ghuma diya h to ab pta nhi chl rha ki screw kitna tight ya loose rkhna h
Hello Bhai ,Maine Kenstar ka 25 litre ka geyser install karaya Aaj , jis bande ne lagaya hai usne safety valve nhi lagayi , lagana jaruri hai kya aur price kitna hota hai valve k
Sir mere पास AO SMITH का ३ltr का geyser ४ साल पुराणा है. अभी मैने उसका coil change' kiya है. लेकीन उसके INline pipe se पानी return आ रहा हैं. Aur baki nal se भी आता है. ऑटो cut ho raha है. Plz
सर मैने कल एक जगह crumpton का 15 लीटर गीज़र फिटीँग से नीचे उतारा , नीचे उसको टेढ़ा करने पर outlet से पानी थोड़ा सा निकला पर उसके inlet valve से पूरा पानी बाहर आ गया और गीज़र पूरा की पूरा खाली हो गया ,पर गीज़र तो अपना water storage रखता है ताकि कोई falt ना हो तो ये inlet valve से सारा पानी बाहर कैसे आ गया ? क्या inlet valve खराब है ?
Sir geyser se garm pani inlet me wapas kyu aa raha hai,. Or inlet pipe se hokar wapas saplie me garm pani aa raha hai kyu ho raha hai aisa pls reply kare
#TIME WEST# Yeh sefti volve bilkul bekar hey.Is volve sey pani back marta hey. Multy function sefti volve lgain jismain pani sirf input hota hey back nahi aa ta .
@@tech.Appliances मैंने पूरी पानी की लाइन साफ कर ली। कुछ भी कचरा नहीं मिला। गीजर भी साफ करा लिया पर समाधान नहीं निकला। मैंने अपने एक गीजर का कनेक्शन बाथरूम और किचन में लिया हुआ है। उसकी वजह से तो ये प्रोबलम नहीं होती क्या?
Geyser ke kuch der chalne ke baad safety valve se paani leak hota hai. Kya thermostat kharab ho gya hai, ya drum phat gya hai? Idhar koi bhi aapke jaisi knowledge wala nahi hai. Kisi ko kuch kaam dhang se nahi aata. Aapki video dekh ke khud hi samajh rahe hain. Thank you.
It's a good and useful video. Thanks for sharing this information
It's my pleasure
Safty Valve se pura din Pani lekage ho raha hai, valve bigad giya hoga ya geyser mai kuch or problem hoga. Solution kya hoga is problem ka.
Change thermostat and safety valve
Same question
Sirf safety valve change karn h ya or bhi kuch
Khud karsakte h ya electrician se hi change karwaye
Aap ne hi. Beji Val pe vidio Banaya good
Kya ji
Are Bhai kaha lagana hai cooling water me ya hot water me
Cool
Do we need to install this pressure valve for the top floor house?
If the water pressure is low then remove the spring from the value and then install it to the geyser.... Do not operate without safety value.... I'm going to do the same at my home...
Bhai paani slow araaha ha because of low pressure kuch kar sakhte hai iss valve ke sath
No
Bathroom renovation k time geasure utara tha , wapas lagaya to ab valve on krte hi safety valve se paani aata h bht tez! Valve band krne k baad b paani aata rhta h 5 min , kya solution h?
Valve kharab ho gea hoga
Safety valve complete close karni hai ya open ?
Woh company ka apna apna hota hai
Meri Astra company ka hai 8 litre wala...uski safety valve band kar dia hai electrician ne while installation.. any safety issue for family?
@1985hunny thoda kaam tight hota hai
cold line pay lagta hai k hot line pay?
Cold line
Kya iski vjaah se pani ki speed kum ho skti? Mere geyser mein outlet se kum pani aara
New geyser or old
@@tech.Appliancesold Bajaj geyser (Shakti plus 15 litre). Ek din Maine geyser off nhi Kiya tha, woh cut off ho gya tha ..next day se Pani Kum aane lag gya outlet se. Kya dikkat ho skti
@@tech.Appliancesshyd overheat hone se kuch toh ho gya hai, jiski vajah se outlet se bahut dheere Pani aa ra... Kya kr skte iske liye sir
@@tech.Appliancespressure release valve lga hua hai, jaise aapke video mein hai... Old geyser
@@ArshdeepSingh.. service kijiye
Bhaiya safety valve to laga hua hai gyser me to kya iske sath mfv bhi lagwana jaruri hai kya??? Please reply....
Mfv means
@@tech.Appliances multi function valve* bhaiya..
sir g screw ko kitna tight ya loose m adjust kare ? plz reply🙏🏼
kiyonki mne usko screw drive se ghuma diya h to ab pta nhi chl rha ki screw kitna tight ya loose rkhna h
Half
@@tech.Appliances half kitna ?
jo wo ek chota sa hole hota h jisme paani niklne ka, usme half pench aur half spring nazar ana chaiye kya Aar-paar ??
@@tech.Appliances mera mtlb us chote se hloe me se pench ki chori dikhni chaiye ya nhi mtlb sirf spring dikhna chaiye kya pench hole se bhar ho ??
Hole se bahar
@@tech.Appliances thnku sir g 🙏🙏🏼 Apke btaye hue se kr diya fitting
Geyser installation ke baad garam pani pure water tank me phuch gya
Ye safety valve ke karan ho sakta hai kya sir
Same here bahi kya pata chala
Sir, iss valve ko nikaalnay se kuch problem hai ? Iss valve ka vajay se shower mai pressure kum aa raha hai
Es se Koi problem nhi hota sir
Sir aur bhi ek pvc pipe jo hai voh kya hai us ka kya kam hai
Bhai element mein bhi koi safety valve hota hai?
No
@@tech.Appliances matlab mera kaat diya electrician ne
Sir valve ke screw ko kitna tite kare
Jitna leak na ho
hamaray gyser ka sefety wall tot gya hai plumber nay usmay mseal laga di kya wo kam karay ga
Change valve
Very nice 👍👍👍👍👍
Iss valve ko pura tight kr dena hai ya fir dheela rakhna hai
Half, aur jis se pani leak na ho
Thanku sir g
Sir maine geyser new lgaya tha tab bhi pani kam ata tha lekin ab to bilkul pani kam aa rha hai kya problem ho sakti hai sir
Check tap jali
Sir jali to nikaal rkhi hai pipe vi clean hai phir bhi problem hai
Agar valve ka spring hata de to koi farak padta hai kya
Water leak
Bhai yeh vavel kaha milega, or yeh kitne inch ka hota hai, maine electrocution ko bulaya tha wo 2000 mang raha tha.
Sir paani bahur jyada garam ho ke aata hein isse
Temperature adjust kse kare
Koi idea?
Niche cover me temp control lga hai, check my channel video
Sir kitchen gyser band karna bhool gye 3 ggante baad dhyan aaya lekin auto cut se band tha ab plug nikal diya kya light utni hi kharch hui hogi
Yes, auto cut ho jata hai, auto cut per NO bilji
Mere Jigar ke donon pipe se garm Pani aata hai iska solution bataiye
Hello Bhai ,Maine Kenstar ka 25 litre ka geyser install karaya Aaj , jis bande ne lagaya hai usne safety valve nhi lagayi , lagana jaruri hai kya aur price kitna hota hai valve k
250 RS jaruri hai pani back nhi jayega
Link is not showing proper result... please provide propre link
Bro safety valve se panni leak horah kya kare
Don't do anything. Ese hi chor do. Leaking means it's working properly.
Sir geyser 10 din phle lgaya but outlet se pani pressure bhot kmm aa rha hai ...any solution sir 🙏
Check tap jali
@@tech.Appliancessir mera geyser seh garam pani wash basin meh aara hai bathroom peh thoda garam hara dusra tap meh bhaut garam pani hara please solution sir
@@rsvvprasad6263 plumber se tap or pipe check karvao geyser ok hai
Hello my Geyser Safety valve is missing .Could u give me the link of this valve .
Online not available
Bajaj ka geyser hai uske inlet me return garam pani aata hai kya karna hoga batao please
Nrv valva lga dijiye
सिम्फनी का 15 ltr का गिझर है,उसके सेफ्टी व्हॉल्व से पानी बहोत लिकेज हो रहा है और इनलेट का अंदर का पाईप दो जगह से लिकेज है क्या करे
Change assembly
Good tiching karte hai 👌👍👌👌👌👍👌
Thanks
Sir nesway ka geyser hai oski red light off nahi hoti aur water bhi boil hota hai 😐 abhi 2 weeks huye liya ko
Pehle hoti thi off,
@@tech.Appliances nhi bhai green light auto cut krdeti thi lekin ab woh bhi autocut nahi kar rahi 🥲🥲 aur paani andar boil ho rha hai
Company Se complain kijiye
Mere geaser voltase se bhee pani leaj karta hai iska kara batai
Change thermostat and valve
Sir mere पास AO SMITH का ३ltr का geyser ४ साल पुराणा है. अभी मैने उसका coil change' kiya है. लेकीन उसके INline pipe se पानी return आ रहा हैं. Aur baki nal se भी आता है. ऑटो cut ho raha है. Plz
Insert NRV Valve in inlet
@@tech.Appliances sir usme already pressure valve hai. Usme NRV valve kaise lagaye?
amzn.to/3WwPyUi
This product use inlet
@@tech.Appliances Thank you sir
Mere geyser ke donon pipe se garm Pani aata hai iska solution bataiye
Kuch solution mila?
Sir greaser me cold water tap on kar ke off karthe he sound kye haha he jawab dijiya
Kya
Kuen tap me se awaz atii hein
Nk
Tap on hotehe greyser ke steel pipe me se sound hata hein. Reply pls.
@@chandbasha6326 sir kitna purana hai geyser, vaise to tap me avaj aati hai kae var
Thanks bro
Racold geyser Mein Garam Pani Nahin a raha hai lekin geyser chalu he dono lite be aa rha he sir plz reply
Element change
Sir hamara geser to on hai Lekin pani nahi aa raha hai nalke se kya problem Ho sakti hai sir jii
Service hogi
Valve 1 pc hi lagta hai kya
Yes
thnx for the help
Sir mere inlet valve toot gaya hai aur uska Chhota choodi wala tikda assembly m rah gaya hai, kaise thik kare
Check another video in my channel
Good information sir
सर सेफ्टी नट को टाइट करने से कुछ नुकसान तो नही
Jda nhi karna thoda kar sakte hai
Jisme garam Pani ka connection nhi h usme bhi garam Pani a raha hai kyu?
Back a raha h pani
Same problem
Auto cut kaisy badhatay hai. Hamaray geyser mai pani zyada garam nahi hota. Jaldi auto cut hojata hai. Please help
Niche vala cover khol kar,
Garm paani back bhej reha hai jeha se thnda paani aata hai ,ushne sare pipe khol diye ushka kiya ilaaj hai
Use nrv valve
Nrv ko geezer ma kha par lagya same hi geezer jaisa video ma hi
Inlet
Service k baad over heat se jo bund bund krke paani niklta hai vo bnd ho geaa hai, pls koi dolution btao
Bund bund water normal Sahi geyser me nahi aata
Send link
Sir ye valve mngwana h order kaise hoga
Online nhi hai, Ham bej denge 400 rs lgega
Nhi bhuta jada price bata rhe h ap
Sir delivery HI bahut lad jati hai 150 rs tak 100 ka valve, fir time bhi lgta hai pehle leke aao fir packing fir jake post kro 2 hour me kaam hota hai
सर मैने कल एक जगह crumpton का 15 लीटर गीज़र फिटीँग से नीचे उतारा , नीचे उसको टेढ़ा करने पर outlet से पानी थोड़ा सा निकला पर उसके inlet valve से पूरा पानी बाहर आ गया और गीज़र पूरा की पूरा खाली हो गया ,पर गीज़र तो अपना water storage रखता है ताकि कोई falt ना हो तो ये inlet valve से सारा पानी बाहर कैसे आ गया ? क्या inlet valve खराब है ?
Vaise normally sara pani nhi niklta
very good
but my safety valve is different type not like dis..please reply
No issues sir, work same hai
Price bhi bataye
50
Sir link
Humhare geyser me inlet pipe se garam paani aa rha hai ... kya problem hai
Sir inlet pipe kholi keo, only outlet hi khole
Inlet ka pipe v black ho gya h or water linkage v ho RHA h geyser lite v nhi dikha RHA iska reson kya h...? Or use kese thik kre..?
Mere hisab se short Ho gea hoga wire jaal gae hogi
Sir geyser se garm pani inlet me wapas kyu aa raha hai,. Or inlet pipe se hokar wapas saplie me garm pani aa raha hai kyu ho raha hai aisa pls reply kare
Pipe galt to nahi ldi
Btao hmare gyser me bhi same problem hai
Overheat ke karn bhi Ho jata hai
Pipe air leti Ho to bhi
Ja Koi or tap sath me joint Ho to bhi
Bhai jb geyser open krta h to thore der baad green light bnd ho jati h hindware company geyser ki
Yes auto cut hota hai, garm hone k baad
@@tech.Appliances thnq
Inlet kon sa hai
Right side pipe , jaha se pani ander jata hai
Kaise pta chalega ki pani ja rha h
Tap se air ki avaj ayegi
Thanks
sir meray gyser ka safety valvet tooot gaya ha.waha say panee nikal raha ha
Sir tut gea ta assemble change hogi
@@tech.Appliances sir adha hisa input pipe ka ander ha
Sir input pipe vala safety valve kohl kar new lgado
Veri naic
#TIME WEST#
Yeh sefti volve bilkul bekar hey.Is volve sey pani back marta hey.
Multy function sefti volve lgain jismain pani sirf input hota hey back nahi aa ta .
Nice paji
lose kyo karna hota h
Kya?
Safety value full tight or full open
Full tight
Ok tq sir but water pressure on very slow why r problem ,my geyser 8bar pressure but normal pressure. please give me solution full pressure water
My geyser water pressure 8bar ,but noraml pressure water came why r u probalm bhai please solution
Hindi me pusiye
Ino hindhi only telugu, English bhai
मेरे गीजर (thermoking) से गर्म पानी कभी कभी स्लो आता है तब मुझे आउटलेट पाइप से हवा बाहर निकालनी पड़ती है। इसका क्या समाधान है?
Main water tanki aur geyser ME kitna difference hai
@@tech.Appliancesmera ground floor ka house hai aur water tanki bathroom ke upar hai. 1/2 meter ka difference hai. Par pahle ye problem nahi aati thi.
Ha sir g mujhe bhi bataye ki akhir aisa kyu ho raha hai
Sir tap me kachra Ho sakta hai
@@tech.Appliances मैंने पूरी पानी की लाइन साफ कर ली। कुछ भी कचरा नहीं मिला। गीजर भी साफ करा लिया पर समाधान नहीं निकला।
मैंने अपने एक गीजर का कनेक्शन बाथरूम और किचन में लिया हुआ है। उसकी वजह से तो ये प्रोबलम नहीं होती क्या?
Geyser ke kuch der chalne ke baad safety valve se paani leak hota hai. Kya thermostat kharab ho gya hai, ya drum phat gya hai?
Idhar koi bhi aapke jaisi knowledge wala nahi hai. Kisi ko kuch kaam dhang se nahi aata. Aapki video dekh ke khud hi samajh rahe hain. Thank you.
Change thermostat and safety valve
@@tech.Appliances Thank you. Aapki video dekh ke mujhe bhi yahi laga tha. 🙏
Thanku sir g
bhai geyser ke net se Pani bahar a raha hai kya problem ho sakti hai main net be tight kar tab bi a raha hai.
Kon sa nut center me jo hota hai