13 common causes of motor failure

Поділитися
Вставка
  • Опубліковано 23 гру 2023
  • 13 common causes of motor failure.
    Power quality
    1 - Transient voltage
    Impact: Motor winding insulation breakdown leads to early motor failure and unplanned downtime
    2 - Voltage imbalance
    Impact: Imbalance creates excessive current flow in one or more phases that then increases operating temperatures-leading to insulation breakdown
    3 - Harmonic distortion
    Impact: Decrease in motor efficiency results in added cost and an increase in operating temperatures
    Variable frequency drives
    4 - Reflections on drive output PWM signals
    Impact: Motor winding insulation breakdown leads to unplanned downtime
    5 - Sigma current
    Impact: Mysterious circuit trip due to protective earth current flow
    6 - Operational overloads
    Impact: Premature wear on motor electrical and mechanical components leading to permanent failure
    Mechanical
    7 - Misalignment
    Impact: Premature wear in mechanical drive components that leads to premature failures
    8 - Shaft imbalance
    Impact: Premature wear in mechanical drive components that leads to premature failures
    9 - Shaft looseness
    Impact: Premature wear in mechanical drive components that leads to premature failures
    10 - Bearing wear
    Impact: Accelerated wear on rotating components resulting in bearing failure
    Improper installation factors
    11 - Soft foot
    Impact: Misalignment of mechanical drive components
    12 - Pipe strain
    Impact: Shaft misalignment and subsequent stresses on rotating components, leading the premature failures
    13 - Shaft voltage
    Impact: Arcing across bearing surfaces create pitting and fluting resulting in excessive vibration and eventual bearing failure

КОМЕНТАРІ • 8

  • @bobcocampo
    @bobcocampo 7 місяців тому +1

    How can ground fault monitoring predict possible failure of motors?

    • @ElecEngineer
      @ElecEngineer  7 місяців тому

      You can use a carbon brush probe attachment, to measure.

    • @bobcocampo
      @bobcocampo 7 місяців тому

      @@ElecEngineer
      Any technical research on ground fault monitoring meter and correlation with motor failure?

  • @bobcocampo
    @bobcocampo 7 місяців тому

    How is voltage affecting the efficiency of motors?

    • @ElecEngineer
      @ElecEngineer  7 місяців тому

      Transient voltage, under voltage or overvoltage?

    • @bobcocampo
      @bobcocampo 7 місяців тому

      @@ElecEngineer
      Both. Utility may use under voltage to increase electricity bill

    • @ElecEngineer
      @ElecEngineer  7 місяців тому

      ​@@bobcocampothe bill is paid for the kw not the voltage neither the ampere, so the bill won't be affected by reducing the voltage, the under voltage has effects on the electrical equipment & cables but not the bill.

    • @bobcocampo
      @bobcocampo 7 місяців тому

      @@ElecEngineer
      Voltage has an effect on efficiency