Motor Star connection and Delta connection difference in hindi | understand star and delta function

Поділитися
Вставка
  • Опубліковано 30 вер 2024
  • Three phase motor connection different work in hindi - why motor connect in star - induction motor connection types - benifit of delta connection - Electrical Dost
    I am Aayush Sharma Welcome to Our UA-cam channel Electrical Dost.
    About this video-
    Dosto Aaj Ki Is Video Me Maine Aapko motor star connection and delta connection difference Btane Ki Kosish Ki Hai Or Kuch electrical tips jaise why we use star connection motor, star and delta working and function, electrician how to use motor starter in hindi, electrical formula, electrical industries work and Electrical interview questions answers Share Kiya Hai Umeed Hai Aapko Ye Video Bahut Pasnd Aayegi (hindi)
    Thank you so much..........
    ........................................................
    इंजीनियरिंग से जुडी पोस्ट हिन्दी मे पढ़ने के लिए हमारी वेबसाइट इंजीनियरिंग दोस्त (Engineering Dost) से जरूर जुड़े।
    .........................................................
    ↓↓ Our Some Other Videos ↓↓
    MCB and MCCB Difference in Hindi
    • mcb and mccb differenc...
    ..
    MCB vs RCCB Difference
    • mcb vs rccb difference...
    ..
    Dol starter power and control.
    • Dol starter in hindi d...
    ..
    how to read motor nameplate.
    • motor nameplate in hin...
    ..
    cable size calculation for electric load
    • Cable size calculation...
    ..................................................................................................................
    Queries Solved:
    1) Why we Connect Motor in Star
    2) which motor use star delta starter
    3) Motor Star connection explained in hindi
    4) Electrical Engineering (Industry)
    5) electrical engineering practical knowledge
    6) simply electrical
    7) starter uses hindi
    8) types of Starter hindi
    9) Star Delta Connection
    10) how to select different types of motor connection
    Email - Aayushsharma0713@gmail.com
    #motorconnection #whystarconnection #stardelta #electricaldost #electricalhindi
    Don't forget to SUBSCRIBE electrical dost for more Trusted electrical videos.

КОМЕНТАРІ • 1,6 тис.

  • @paras_education_site
    @paras_education_site 4 роки тому +178

    Nice video sir ji aaj pura daut clear huaa star delta ka THANKS YOU SIR JI

    • @iqwalkhan5481
      @iqwalkhan5481 4 роки тому +12

      Aap ki jankakari sahi nhi hay motar istar man chalagi ya dalta man yah uski wainding say Tay hoti hay aap Kay ya Mary hisab say nahi jis motar ko istar man Chala na ho ta hay us Kay sirf ten wayar kanaksan pilat man daty han r y b jis motar ko dalta kanaykt kartyhan uskay 6 wayar a1 b1 c1 a2 b2 c2 saplai kaliy hoty han Jo badi h p ki motar hoti hay unko istart karnay kaliy pahalay istar bad man dalta man saplai Dee jatee hay Bo is lit ki jab ko ham istart karty hay tab apnni chmta ka teen guna karant lati hay issay bachnay kaliy asa kartay han agar aap koi or jankakai chhaiy to likhna

    • @NeerajKumar-cm2dr
      @NeerajKumar-cm2dr 4 роки тому +3

      Parasbdevasi Paras

    • @krishnagond9546
      @krishnagond9546 4 роки тому

      Oooooo nice

    • @electricaldost
      @electricaldost  4 роки тому +5

      आपके कांटेक्ट नंबर भेजिए, मैं आपको कॉल के माध्य्म से बताने की कोसिस करता हु।

    • @KuldeepSingh-me1or
      @KuldeepSingh-me1or 4 роки тому +1

      ThannkS

  • @shivshaktisoundkalu
    @shivshaktisoundkalu 4 роки тому +43

    भाई साहब स्टार डेल्टा स्टार्टर पैनल को थोड़ा सा एक्सप्लेन करके वीडियो बनाइए ताकि स्टार डेल्टा पैनल और कांटेक्टर के कनेक्शन समझ सके

  • @GNXDC
    @GNXDC Місяць тому +2

    Thanku so much aap hi hamare asli dost ❤

  • @Moviezones77
    @Moviezones77 Рік тому +8

    Sir आपने जो वेबसाइट बनाई है, वो सचमे बोहोत बढ़िया है, हमे जल्दी समझ मे भी आती है, सर मै आपको दिलसे धन्यवाद देना चाहता हु, जो आपके वजह से मै बहुत कुछ सीख पा रहा हु 😇thank you sir 🙏💜

  • @shubhamroy8359
    @shubhamroy8359 3 роки тому +1

    Connection efficiency pe depend nahi krta.
    Hum star connection isliye krte hai taaki motor starting me less current le.
    Uske baad jab motor stable hojati hai tab hum delta connection krke full current pe kr dete hai motor ko

  • @danishraza8746
    @danishraza8746 4 роки тому +16

    You people are doing a great job through your website.
    Well done 👍
    I urge you to work on more mechanical topics like bearing, coupling, fan, hydraulic, pneumatic, rotating equipments, Belt conveyor, workshop related machines, cutting tools, material science etc.

    • @electricaldost
      @electricaldost  4 роки тому +2

      Thanks sir for supporting us
      😊🙏
      Mai aage or bhi mhent krunga.

    • @jollyscaria1922
      @jollyscaria1922 2 роки тому

      Not payed tockingood way all

  • @electrician-b7s
    @electrician-b7s Рік тому +1

    Sir .motor Star connection starting running capacitor connection kese kare ek video banay . Please 🙏🙏

  • @sarabjitsidhu6928
    @sarabjitsidhu6928 4 роки тому +6

    Star connection is used in high load motors for starting only not for efficiency purpose.B cause when we start high load motors in delta it requires high current to start which can blow our supply so the connection is changed to star to start motor and when motor achieves speed then changed to delta.

  • @hselectro7458
    @hselectro7458 3 роки тому +2

    Sir mein 3hp ki motor use krta hu jiska jerk load 5-6amp 1 sec ke liye jaata hai..aur fir wo normal 3amp pe aa jaati ... iske liye koun sa connection best rahega star ya delta.....

  • @shamibhutt4680
    @shamibhutt4680 4 роки тому +5

    Sir ur all videos on electric to much informative and understandable in simple language
    It's very useful in my work if me have any problems in my work I watch ur videos and my work done
    Thanks aloot for ur efferts God bless u
    Love and respect from Pakistan 🇵🇰🇵🇰🇵🇰🇵🇰

  • @suvarnaburange3599
    @suvarnaburange3599 2 місяці тому +1

    Affacancy 😂😂😂
    Pronounce it correctly
    Its efficiency

  • @darshanchavan1803
    @darshanchavan1803 4 роки тому +8

    Sir your teaching is in simple language ,and understand easily thank u sir

  • @jaideepdalal3971
    @jaideepdalal3971 Рік тому +1

    Jai Dada Shyam ji ki 🙏🙏❤️❤️

  • @rv411cc
    @rv411cc 3 роки тому +7

    Sir i am a Mechanical Engineer...
    But your video literally interesting and made me to learn about electrical concepts..😇😇😇

  • @siddharthsharma5190
    @siddharthsharma5190 4 роки тому +7

    Thanks alot brother ur videos are giving excellent learning, they made engineering just a fun...

    • @rjwantkaur5209
      @rjwantkaur5209 4 роки тому

      ua-cam.com/channels/owxc6ikTiZqoIekSQGxjUQ.html

  • @theneutral5831
    @theneutral5831 3 роки тому +7

    Simple and effective. Thank you.

  • @deepanshusingh7765
    @deepanshusingh7765 2 роки тому +1

    Website k sath... Mobile Application bhi hai kya ?

  • @farooq8899
    @farooq8899 3 роки тому +4

    Good morning bro. Can you explain 3 phase two speed motor and connection, circuit diagram. And can we run two speed motor star or delta ?

  • @haroonshaikh1847
    @haroonshaikh1847 Рік тому +1

    Concept not clear unnecessary explanation

  • @varinderkumar4904
    @varinderkumar4904 4 роки тому +3

    If we change the connections from delta to star them what about the rpm sir? Make it clear.22kw 3 phase motor with delta connections drawing 41.5amps .if we change the connections from delta to star what about rpm and amps thanks

  • @harekrushnasahoo305
    @harekrushnasahoo305 2 роки тому +1

    HPSV LAMP MAY IGINITOR KA KAAM KAY HAI PLEASE BATAO

  • @enigmaviki
    @enigmaviki 4 роки тому +14

    All College professors should learn from this guy! Great video

  • @tejaspatil3978
    @tejaspatil3978 4 роки тому +2

    Sir , I'm iit student from IIT bombay. But sir i see only your video of electrical which is very easy for me and you explain topics in very easy concept
    Sir, can you have make WhatsApp group for electrical ..

  • @JamilKhan-ui8hz
    @JamilKhan-ui8hz 4 роки тому +20

    Aap
    ne jis Tarah se samjhaya Woh tarika bahut he badiya tha ,, bahut aacha Like like Like

  • @nimasangay8729
    @nimasangay8729 3 роки тому

    Mera wood trimmer input voltage hai 120V .kiya Mai isko 220V de sakika ya ham ko voltage regulator through dena pariga.please give your suggestion

  • @RajeshKumar-pt2nx
    @RajeshKumar-pt2nx 4 роки тому +5

    How to make a stripe on wire we need a tool

  • @niharranjanpradhan8633
    @niharranjanpradhan8633 4 роки тому

    Bro ur wrong 440v calculations of 3 phase neutral to phase is 220v so u said every winding is get 440v at delta connection how so plz learn first then try to teach I saying u because I am an engineer

  • @bunty3798
    @bunty3798 3 роки тому +35

    Aap ki har video me khas baat ye hoti h ki aam insaan jisko normal electrical knowledge bhi ho wo asaani se concept samajh jata h. Thank you very much.....For spreading knowledge to everyone.

  • @rahulnaudiyal06354
    @rahulnaudiyal06354 4 роки тому

    Sir मेरी मोटर 7.5 hp की है... और मुझे गेहूं का थ्रेशर चलाना है... Rpm 1450...मैं start connection करूँ तो कोई दिक्कत तो नहीं है... क्यूंकि... वो थ्रेशर को ज्यादा भगा रही है...और लंबे समय तक start कनेक्शन 20-25 दिन तक चलाएंगे तो प्रॉब्लम तो नहीं होगी......

  • @namtere4776
    @namtere4776 4 роки тому +5

    आपका वीडियो बहुत अच्छा लगता है सर बहुत जल्दी समझ में आ जाता है सर जी फ्री फेस मोटर को 220 में कैसे चलाया जाए इसके ऊपर भी वीडियो बनाइए

  • @telomerestelomeres7775
    @telomerestelomeres7775 4 роки тому +1

    I gave my motor for rewinding after it has burned up. . It is 10 hp motor. How would I know which winding they have done to my motor. How many types of winding are there.
    I run my motor by star delta starter. So which winding is recommended for the star delta starter. My motor is 10 hp.
    Please answer.

  • @ssraorao7565
    @ssraorao7565 4 роки тому +7

    Excellent information sir thank you very much

  • @mohammadabrar7813
    @mohammadabrar7813 3 роки тому

    आपका वीडियो ठीक है, लेकिन डेल्टा कनेक्शन करके बताना था। जैसे U coil Ka start U¹, End U²,V coil Ka start V¹ end V², W coil Ka start W¹ end W²
    Connect U¹W² phase R, V¹W² Phase Y, and W¹U² Phase B.

  • @Bageshwar-k3d
    @Bageshwar-k3d 4 роки тому +4

    अति सुन्दर

  • @dr.anshumangupta6902
    @dr.anshumangupta6902 4 роки тому

    मेरी submrcible motor १०hp low voltage ३२० बाइंडिंग KSB है. जो कम voltage आने के कारण लगवायी जिसे डेल्टा मे चलाता था . अब मैंने transformer लगवा लिया है जो अब फ़ुल voltage देता है. अब मैं मोटर को star पर चलाऊँ या delta पर। ..??

  • @rajeshkumarpatel7738
    @rajeshkumarpatel7738 4 роки тому +13

    बहुत सरल सहजता से समझाया है ग्रेट सर जी।

  • @aftabealam4065
    @aftabealam4065 4 роки тому +1

    Bohot Shukriya Bhai ji.. _/\_
    1 question hai...
    Agar ek winding coil jab ek hi continue conducting medium (wire) hoti hai...toh winding ke do chhorr(ends ya kinaarey) alag alagg polarity (yanee.. ek Phase aur ek Neutral) kaisey hogaey..???
    Jaruur mera doubt clear kariye Bhai Ji...

  • @satishverma1130
    @satishverma1130 4 роки тому +5

    बहुत अच्छी जानकारी दी बहुत बड़ा संशय दूर हो गया

  • @ravindrabhardwaj6464
    @ravindrabhardwaj6464 3 роки тому

    15 सेकेंट तक स्टार में, फिर अपने आप डेल्टा में चालू ,ऐसी मोटर के पैनल को समझना था,,मोटर के टर्मिनल में 6 वायर हैं,, क्या आप समझा सकते हैं,,please reply

  • @AIMELEVATORSERVICES
    @AIMELEVATORSERVICES 4 роки тому +5

    Super

  • @qdvidzone1890
    @qdvidzone1890 2 роки тому

    Connection part Peoples will confused the way u tought ..u must draw star n delta connection diagram n show them how they connected...

  • @vipinkant9542
    @vipinkant9542 4 роки тому +7

    Bro your concepts is clear fantastically. Hats of 🙏
    Its helpful to everyone in esay language

  • @mahendrasul9218
    @mahendrasul9218 2 роки тому +1

    Dear sir,I required copper cable and aluminum cable current rating with formula
    Sul

  • @hajimuhammad2928
    @hajimuhammad2928 Рік тому +3

    Thank You Very Much, Sir.
    5 Stars = 🌟🌟🌟🌟🌟
    5 Likes = 👍👍👍👍👍
    💯 % Learning
    Your Video Presentations Are Together A Conducive Environment For Exceptionally Learning of Jet Stream of Knowledge Imparted To Us With The Talent With Which Knowledge Is Taught By Your-Good-Self.
    Thank You Once Again 🙏
    From, Karachi, Pakistan. 🇵🇰

  • @rajukarmakar8424
    @rajukarmakar8424 4 роки тому +2

    Please make some HVAC related videos

  • @nareshdadi1441
    @nareshdadi1441 4 роки тому +5

    Thank you for valuable concepts..

  • @ramchandrachoudhary5195
    @ramchandrachoudhary5195 4 роки тому

    सर सिंगल फेज में कितने की मोटर चला सकते हैं और एक सौ साठ फीट से कितने इंच का पानी निकल सकता है और सिंगल फेज में सबसे अच्छा मोटर कौनसा होता है यानी भाई साहब मैं एक सौ साठ फीट से सिंगल फेज से पानी निकालना चाहता हूं तो मुझे कितने किलोवाट कि मोटर लेनी है कौनसी कंपनी की लेनी है कितने का टारसफारमर लगाना चाहिए इससे संबंधित सलाह दें आपका आभारी रहूंगा 6375061451

  • @hiteshsoni7448
    @hiteshsoni7448 4 роки тому +3

    Thank you Dost🙏

  • @sjaman9599
    @sjaman9599 3 роки тому

    Sir. Muje 5hp.abb motor. 1425rpm.3phase ki rewainding data. Plz

  • @chandrasekharbuda2377
    @chandrasekharbuda2377 4 роки тому +4

    Thank you sir

  • @koss4439
    @koss4439 3 роки тому +2

    Thanks u so much for getting me so knowledge by ur best explanation.

  • @kapiljettiwar6213
    @kapiljettiwar6213 4 роки тому +1

    🙏

  • @mustardoilmillbusiness8868
    @mustardoilmillbusiness8868 3 роки тому +1

    oil machine ki motor 10 hp ki hi ... Mujhe uska connection star me karna chaiye .. ya phir Delta me karna chaiye .. bataye pls

  • @autoliftin6291
    @autoliftin6291 4 роки тому

    Jab tumhe samjhane Nahi ata hai to video kyo banate ho her PHASE KO indicat Karo jaise A1 A2 ,B1 B2,,C1 C2 ,A1B1C1 star point Hoga short karne seA2B2C2 per supply dene SE star canection Hoga A1B2,B1C2,C1A2 to star delta connection Hoga

  • @kundansharma1867
    @kundansharma1867 Рік тому

    सर डेल्टा कनेक्शन में neutral कहां से प्राप्त होता है
    Kundan Sharma

  • @SaiPr17
    @SaiPr17 3 роки тому

    one request dont use sketch pen... the sound it makes while writing is uncomfortable... no offence

  • @Amisimpi23122
    @Amisimpi23122 3 роки тому

    सर मैंने 1 hp मोटर लाया हूं लेकिन उसमे 30" का फंखा ब्लेड लगाया लेकिन 5 min चल रहा है लेकिन मोटर हीट हो जा रहा है लेकिन कनेक्शन स्टार में है नया मोटर जब आया था तो कनेक्शन स्टार में ही था कृपया आप बताइए कि क्या करे की मोटर हीट ना हो

  • @fulendrajha1361
    @fulendrajha1361 2 роки тому

    स्टार डेल्टा जो बताए बहुत अच्छा लगा लेकिन कुछ बिडीयो दिखाई नहीं देता है स्किन बड़ा कर समझाएँ

  • @vishalgaikwad4570
    @vishalgaikwad4570 4 роки тому +1

    Star - delta Auto / manual wiring sikhao...with selector switch

  • @avinashsinghyadav2405
    @avinashsinghyadav2405 3 роки тому

    सर एक विडियो बनाइए स्टार डेल्टा स्टार्टर से स्टार में और फिर डेल्टा मे मोटर चलाने का मतलब क्या होता है?क्या इसके अलग-अलग घूमने की दिशा और धारा लेने की मात्रा भी बदल जाती है?

  • @ashokbhaipatel8020
    @ashokbhaipatel8020 4 роки тому

    मेरे पास 15HP 960RPM की मोटर है जो लकड़ी काट ने की आरा मशीन पर फीट करना है
    जो लोड में चलेगी और उसका स्टाटर नीचे दबाकर मोटर रनीग होने के बाद ऊपर करना है तो इस मोटर के वायर कनेक्शन कैसे करें बताने की कृपा करें

  • @bhojpurichannel9035
    @bhojpurichannel9035 11 місяців тому

    Kyunki ye motor 5KW hai ,joki 1KW= 1000W, tab 5KW = 5000 W so A ke formula se W/V= 5000/ 415= 12.04 A lena chahiye

  • @desityniranjansss3825
    @desityniranjansss3825 2 роки тому +1

    Thanks sir your vedios and your explanation is very useful for me

  • @HUMANS_AND_ANIMALS8485
    @HUMANS_AND_ANIMALS8485 4 роки тому

    Bhai appki website bhot achi hai pr app अपने article की संख्या बढ़ाए

  • @dineshbambhaniya7036
    @dineshbambhaniya7036 Рік тому

    Thankyu sirji
    મારે શીખવુ છે જો કોઈ શીખડાવતુ હોય તો મને મો.નંબર.આપો.🙏🙏

  • @PrakashChandra-lz9nr
    @PrakashChandra-lz9nr 4 роки тому

    Sir mera cameant... ki wayar swg se rileted altinetor 7eanch cor24 slot 7eanch me kitane no swg lgega 20 kva 25,kva ke liye30kva ke liye,35kva ke liye our tran kitne dalne pdenge 3phej ke liye wayar kitne kg lgega...

  • @pramoddarshandhari2419
    @pramoddarshandhari2419 3 роки тому

    1250rpm salt36pitch8 ko 3hpmotarko kese weding kiya jay

  • @ramandeepsingh4395
    @ramandeepsingh4395 7 місяців тому

    At how many volts does the shunt coil and closing relay operate in ACB?

  • @shaktisharma7786
    @shaktisharma7786 2 роки тому

    Explain with diagram and mathematically calculation with practically explanation.

  • @Cartechbypk
    @Cartechbypk 4 роки тому

    Sir mere pass ek 3 kw ki 3 phase Hydraulics hose crimping machine hai Jo Maine China as mangwayi hai , but abhi mujhe use 1 phase Mai agar run karnar hai to Mai 1 phase to 3 phase vfd drive laga kar kar sakta hu Kya , motor ka connection star Mai Kiya hua hai company se hi. But Maine jab vfd walk de bat ki to unjone maujhe bataya ki apko 1 phase in air 3 phase out vfd Mai out put voltage 220 hi milega to Kya Mai ise Delta Mai convert kar ke 220 volt 3 phase of Chala sakta hu Kya

  • @atulavara9457
    @atulavara9457 3 роки тому

    Sir mujhe 12.5 hp ki motar ko 2phase se clana h to kaise chlaye aur kitne ka capaseetor lgaye 9335592806

  • @Bhogichand
    @Bhogichand 3 роки тому

    डेल्टा कनेक्शन का डायग्राम बराबर नहीं बताया ज्योकी ट्रॅंंग्युलर मे होता है !

  • @rajuparsad4623
    @rajuparsad4623 2 роки тому

    Very helpful video sir thank good information for electrical

  • @sandeepaggrwal7442
    @sandeepaggrwal7442 4 роки тому +1

    Sir kya dono connection se bill me koi farq padta h kya

  • @MK-yi6ye
    @MK-yi6ye 2 роки тому +1

    What will be the current of this motor in star? What will be the 100% setting of relay in star?

  • @nkkatara4797
    @nkkatara4797 4 роки тому

    Bhai kuch video battery ki banao jaise SG UA AH KYA HOTA HAI CAPACITY

  • @sahilshaikh6290
    @sahilshaikh6290 2 роки тому

    Mere industrial men blowers ki motor 7.5 kw ki hen aur 10 .5 amp le rahi hen magar motor fire ho gai hen
    Ab mere pas11 kw ki motor hen aur muje tamprary lagani hen to star conection men kitna amp hona chahiye mera volt hen 420 avraj

  • @msraja4317
    @msraja4317 2 роки тому

    Sir... Mera 3hp motor h jo chakki me use ho rha h. Aur ye dono side chalta. H but. Turan jal jatah... Karan keya h bataye pls. 🙏

  • @saraskumar1260
    @saraskumar1260 4 роки тому

    And No Nc swich limit switch drive and sensor all type plz make video

  • @haa72
    @haa72 3 роки тому

    good please contact for new product development and inspection

  • @haldeeppatle9637
    @haldeeppatle9637 4 роки тому

    Sir mere pass motor hai jo VFD ke sath connect kiya hai VFD input voltage 220 volt hai VFD out putt voltage 3×0 input voltage hai motor connection star me kiya hai load par motor rukh rhai hai unload me koi problem nhi hai kya problem ho sakta hai

  • @birbalyadav9683
    @birbalyadav9683 3 роки тому

    5 kilowatt into 1.7 barabar 8.5Amp
    1 face ke motor Ka aise hi Amp nikala jata hai बताओ

  • @hukamsingh9298
    @hukamsingh9298 Рік тому

    Hello sir
    Auto transformer starter se motor connection star me kre ya delta me motor 110kw ki h

  • @shaktisingh6413
    @shaktisingh6413 3 роки тому

    Sir plss reply
    Kya 7.5 kb ka connection leker usper ham 10hp ka motor chala sakte hai ?

  • @Hindi__kahani.
    @Hindi__kahani. 3 роки тому

    Sir aapne jo bataya usme
    R---------B
    Y----------R
    B----------Y esa hota he na ya sir meri galti ho rai he

  • @venkybadodgi3958
    @venkybadodgi3958 3 роки тому

    Sirji pls power Conte tor me megnetic coil jaise function karta hai thoda batayenge,

  • @bhamraram1365
    @bhamraram1365 2 роки тому

    सर हमारे पास में माना कि सिंगल फेज मोटर है हम उसका गेज भूल गए अगर उसको रीवाइंडिंग करनी हो तो उसको कैसे करेंगे

  • @patelmayur4190
    @patelmayur4190 2 роки тому

    One video HT motor connection and why use star connection In HT motor ...

  • @rajjo2369
    @rajjo2369 Рік тому

    Wo multiplying factor ×1.7 wala wo Jo aaya hai uska video ki link de skte ho kya ?

  • @poojagupta6235
    @poojagupta6235 3 роки тому +1

    A motor is taking 2.1 A no load current in star connection but in delta no load current is 15A. What may be the possible reason?

  • @pavaneshchavan615
    @pavaneshchavan615 4 роки тому

    Mere pass star delta connection he Agar starter R Y B terminal Ko motor B R Y connect kiya to kuch problem ho Sakta he kya ..

  • @shoaibsayyad2738
    @shoaibsayyad2738 3 роки тому

    Jaise aapne bataye ke RYB me har connection par 230V hota hai aise to total 690V hua par hamara 3 phase 440V hota hai
    Kese?

  • @ranjan3140
    @ranjan3140 3 роки тому

    Thanks sir ji plz 🙏🙏 apna contact number dijiye sir ji plzzz 🙏🙏

  • @arjunmohod6022
    @arjunmohod6022 Рік тому +1

    Wow what a beautiful explanation thank you so much bro

  • @hindutvajayshreeram1671
    @hindutvajayshreeram1671 4 роки тому

    Meri machine ki motor thi 1.5 hp ki single phase ,jo jal gayee ,Maine rewind karayee,lekin winding ke bad vo aadhe minutes me bahut garam ho rahi hai aur aavaj jyada karti hai ,winding wala bol raha hai ki tumhare shop me earthing nahi hai ,dimakh ghum gaya hai , solution batao pls.

  • @syamuyadav7963
    @syamuyadav7963 3 роки тому

    Sar jee single phase 3 h.p 2800 r.p.m wali motor 200 volt par Bina kisi load ke kitna ampere legi

  • @Gaurav-oh6eq
    @Gaurav-oh6eq 7 днів тому +1

    Superb quality

  • @gopalbanerjee1338
    @gopalbanerjee1338 3 роки тому

    I have miss star delta motor ferol . How can i find them without open motor .

  • @bollywoodsongs_123-.
    @bollywoodsongs_123-. Місяць тому

    Sir Wiring ki bhi vedios banaiye practically kese karte he wiring aur chhat me pipe fitting kese karte he is par bhi vedios banaiye please🙏

  • @Rahul.patel48
    @Rahul.patel48 2 роки тому

    Huh! Neutral khali naam ka neutral hai baki shock to tagda teda vo bhi…☹️☹️🙁