आपका vdo बहुत ही बढ़िया और सरल है, चाहे time लगे अप एकदम जीरो से पूरा एक एक components के बारे में details मैं बताते हैं जो समझ ने में आसानी होता है 🙏🙏
Great video, kindly also make a video of the same connections with L & T MK1 contactor, GIC under/over relay and GIC liquid level controller along with Auto and Manual changeover switch.
Hello Sir, Please let me know which contactor will be best to use if i have to connect my household electricity load like Air conditioner, submersible pump, washing machine, geyser, TV, fans, etc. In my locality, power fluctuation is very frequent so I want to use VMR with contactor as you showed in the video.
Very good informative video Can you please tell me company name and model name of each component and there capacity 1)MCB Model name company name and capacity 16A , 20A, 25A ,32A etc 2) power contacor company name model name and capacity 3) Voltage controller company name model name capacity 4) single MCB Company name capacity 16A,20A,25A,32A Also I am not getting use of that last single MCB Pl. Provide details on above 4 points Thanks
Mera ek panel mai this relay mai upper side mai 3 phase or nutreal arehai niche 15 or 16 phase arehai lekin relay kha power led on nahi hai age line bhi ja nahire kya problem ho sakthe
Thanks a lot sir🙏🙏🙏 is topic pe video la ne ke liye sir muje app ke help chaiye mera ek 62kva three phase genset hai or me live sound reinforcement karta hu to muje ek 62kva power distributor banana hai jisme over voltage and under voltage protector,over and under frequency protection,over power factor and under power factor and phase sequence protection,and phase failure,neutral protector and surge protector chaiye to kya app please mera help karoge 🙏🙏🙏. Yeah mjue or mere jaise bahot logo ko helpful rahega🙂
Maine same cnnection GIC 800 DMS 120 ke liye apply kiya... Lekin pahile 5second ke liye on hota hai lekin uske bad trip ho jata hai aur red fault ka light on ho jata hai... Kya fault ho sakta hai
Dear Sir, aap ye bataye ki contractor k coil A1 per aap B phase add kia hai .yadi B phase UV hota hai to coil ko off ker dega relay. aap ye bataye yadi R phase UV hota hai to us time kya react Karega relay.?? kya us time off Karega coil ko ? R phase to add nhi hai coil ko. I am waiting ur valuable feedback.
Thanks sir, can you make controlling of 3 input contractors with single output? I have i EB main power anf have 2 DG sets. Need to make controling ckt when EB fails master DG start automatically and if DG 1 fails to start due to any reason, then DG 2 automatically start after some defined time delay. Once EB restore, DG automatically shutndown and power goes from EB contactor. Please make 1 video on this.
Hello Sir, Maine yahi circuit follow karte hue connection kiya hai. VMR hai GIC SM800 DMA 220. But ye circuit trip nahi ho raha hai jab kisi ek phase mein voltage 200V se niche drop kar raha hai...main Under voltage 200V set kiya hai but VMR trip nahi ho raha hai. Plz mujhe help kijiye. Kya VMR mein kuch defect hai ya circuit mein.
Mene reley ke NC me se contactor ko power diya but contactor on nahi ho raha he ,NO me se contactor ko power de raha hu tab contactor on ho raha he,aisa kyu ho raha he ?
hello sir ..hame GlC - Cat ID- ND21DF Series SM175 ke bare me ek video banke hame connection ke bare me details samjai .. Ye ham aapki request karate he..
सर क्या हम इस सिस्टमको अगर तिनो फेज मे से एक कोइ एक फेज मे फल्ट आता हे तो बाँकी दो फेजो को उपयोग कर सकते हे ।और तिनो फेजोमे किसी टाइम फल्ट चेन्ज होता हे तो क्या हम सहि फेजको उपयोगमे ले सकते हे ।
आपका vdo बहुत ही बढ़िया और सरल है, चाहे time लगे अप एकदम जीरो से पूरा एक एक components के बारे में details मैं बताते हैं जो समझ ने में आसानी होता है 🙏🙏
बहुत अच्छा, जितने प्रसंसा की जाए कम है आपने इतने सरल भाषा का उपयोग किया है कि सभी Doubt Video को देख के ही clear हो जाती है....👌👍
Thanks
Han ji Sar trip kaise kiya jata hai
9525918336
Sar ji apna number send kar dijiye
Badi hi sehjta se aap ne samhjya...nice way of explaining things
Bahut accha samjhaya hai sirji, please ELR connection with MCCB bhi sikhao 🙏
Very nice video sir. I really like it. thanks you so much. God bless you
Great video, kindly also make a video of the same connections with L & T MK1 contactor, GIC under/over relay and GIC liquid level controller along with Auto and Manual changeover switch.
Well knowledgeable video thanks you sir
Bhut achha bhaiya ji
Very good explanation,
Excellent sir,
I live in UK and your way of explanation , videos very helpful... So I subscribe your channel now for future video...👌👌
Very knowledgeable video sir
I learnt. Well explained. 🙏🏻🙏🏻
Please subtitle in English.
Nice video. Many thanks.
Well explained... Thq u
Excellent explanation 👌
Bhai ghar ke liye aisa circuit use kar sakte hai?
is aik rely pr kitni 3ph motor apply kr sakty hain?
Dear sir nice explanation useful kindly arrange to add 3 phase surge suppressor to get perfect and quick response
Great videos... pl. highlight the connection points with some pointer/highlighter when mentioning the name.
Sir cold room pe video banaye
Ye realay 3 phase power milega tabhi sens karega??
Very good sir iski comments se wiring diagram batayen
Thank you sir ❤
Kya ham ya cercit house MN istmal kr saktan han
Device ka internal circuit digram mil payega kya sir
Very nice information
Good explanation
Nutul cut ka problem bhi solve ho jayega na sir
Han.
Hello Sir,
Please let me know which contactor will be best to use if i have to connect my household electricity load like Air conditioner, submersible pump, washing machine, geyser, TV, fans, etc.
In my locality, power fluctuation is very frequent so I want to use VMR with contactor as you showed in the video.
Very useful video
Sir mcb tp &s.p kitne amp ki he & cotectar kunsa he batai
Dear I am use this relay for house wiring is it ok
Sir Pata kaise lagaen ki rectifier LG Kom ka hai yah delta ka
Good ! VERY INFORMATIVE
Sir single phase motor me ye device use carsakta he?
Very good informative video
Can you please tell me company name and model name of each component and there capacity
1)MCB Model name company name and capacity 16A , 20A, 25A ,32A etc
2) power contacor company name model name and capacity
3) Voltage controller company name model name capacity
4) single MCB
Company name capacity 16A,20A,25A,32A
Also I am not getting use of that last single MCB
Pl. Provide details on above 4 points
Thanks
Sir hi mera 63 amp Ka load hai
To main contecter kon sa lagana hoga pls batana Thanks in advance
Mera ek panel mai this relay mai upper side mai 3 phase or nutreal arehai niche 15 or 16 phase arehai lekin relay kha power led on nahi hai age line bhi ja nahire kya problem ho sakthe
Last main indication light lagana zaroori hai kya ,qk already 3 phase k leay indication lights hain phr aesa q ,,,plz batana
Thanks👍
Great explain
Ham same wiring connection sm 800 ke liye kar sakte hai kya
Relay ko single phase connection monitoring kar sakte hai...?
اس کو اٹو اور مینول میں چلانے کے لیے کیا استعمال کریں
Bhai soft stater kai bare main videos banayein
Is relay ko 240v single phase monitoring kar skte h plz reply...
Good video sir
Zabardast g
सर यह कितने मोटर पर लग सकता है
Nice sir
Super thank you sir thank you
Sir 3 phase uvr connection kese korna hai.?
Sir mare ghar 3 phase connection hai maine 6 ac hai. 63 amp 4 pole main mcb hai i, overvoltage se kaise protect kru kya lgau ?
ua-cam.com/video/YFyzBk3YIMs/v-deo.html
Use this relay with power contactor
very very nice
Bypass mcb set karni ho to wiring kese karte he
Can this circuit is useful for nitural faliury circuit
If Nuetral Break down from main supply, it's stop main line contactor?
Thanks sir ji
Thank you
Thanks a lot sir🙏🙏🙏 is topic pe video la ne ke liye sir muje app ke help chaiye mera ek 62kva three phase genset hai or me live sound reinforcement karta hu to muje ek 62kva power distributor banana hai jisme over voltage and under voltage protector,over and under frequency protection,over power factor and under power factor and phase sequence protection,and phase failure,neutral protector and surge protector chaiye to kya app please mera help karoge 🙏🙏🙏. Yeah mjue or mere jaise bahot logo ko helpful rahega🙂
Sir push botton se on of kese hoga
Singal mcb kyu lagaya he ? Uska kam kya he ?
great video single phase motor me ye device use kaise carsakta he?
Ye 3 phase ke liye hai.
good
Sir,
If we want to connect vmr sensing phases from out put of power contactor.
Then is it work properly or not.
Not working.
Sir mere me MMR relay Kam nahi kar Raha hai hog ka
सिंगल फेस 32 एम्पियर तक करना होगा तो क्या करे।
Sir ager single phase hai to kis tara connection karein
Maine same cnnection GIC 800 DMS 120 ke liye apply kiya... Lekin pahile 5second ke liye on hota hai lekin uske bad trip ho jata hai aur red fault ka light on ho jata hai... Kya fault ho sakta hai
काॕन्ट्याक्टरका काॕईल व्होल्टेज देना जरुरी है.
Sir ji he software konsa ahe
Very Nice
Sir ov को 110 परसेंट के ऊपर set करने पर nc no चेंज हो जाते हैं ऐसा क्यों हो रहा है
Please explain
Thank you bhaia
Hallo sir,,,can you apply it with manual COS please?
हेलो सर टाइमर लेवल शंशर ओर। फेशाफेलर रिले का सीरीज वायरिग बतव
Safe voltage motor ? UV, OV, single and 3 phase motor.
ON DELAY ke bare me bataya hi nahi
Dear Sir, aap ye bataye ki contractor k coil A1 per aap B phase add kia hai .yadi B phase UV hota hai to coil ko off ker dega relay. aap ye bataye yadi R phase UV hota hai to us time kya react Karega relay.?? kya us time off Karega coil ko ? R phase to add nhi hai coil ko. I am waiting ur valuable feedback.
Tino phase me se kisi ka UV hone par yah Circuit output nahi dega.
3 phase VMR ko single phase mein kise connection Karen
Thank u sir
Sir water chiller three face wiring kaise karen
Will it work in 400c/s
Sir kya aap ye relay Ka company name bata sakte hai?
Gic
Thanks sir, can you make controlling of 3 input contractors with single output? I have i EB main power anf have 2 DG sets. Need to make controling ckt when EB fails master DG start automatically and if DG 1 fails to start due to any reason, then DG 2 automatically start after some defined time delay. Once EB restore, DG automatically shutndown and power goes from EB contactor. Please make 1 video on this.
This circuit will PLC based.
Hello Sir,
Maine yahi circuit follow karte hue connection kiya hai. VMR hai GIC SM800 DMA 220. But ye circuit trip nahi ho raha hai jab kisi ek phase mein voltage 200V se niche drop kar raha hai...main Under voltage 200V set kiya hai but VMR trip nahi ho raha hai. Plz mujhe help kijiye. Kya VMR mein kuch defect hai ya circuit mein.
Check your relay settings.
Phase sequence ultah ho jaye to kya kare iskeliye koyi device Hi kya
Mene reley ke NC me se contactor ko power diya but contactor on nahi ho raha he ,NO me se contactor ko power de raha hu tab contactor on ho raha he,aisa kyu ho raha he ?
I went to know that vmr setting points.
How about time response for over/under voltage ? < 200ms ?
Sir fault hone se reset kese hoga
Any different betwee GIC MG73BH SM500 AND GIC MAC04D0100 SM500
Thanks sir
I am looking for similar device to limit high voltage DC current. Any ideas?
very Good
Sir aap panel ke Saath bata sakte hai video ko
❤
hello sir ..hame GlC - Cat ID- ND21DF Series SM175 ke bare me ek video banke hame connection ke bare me details samjai .. Ye ham aapki request karate he..
सर क्या हम इस सिस्टमको अगर तिनो फेज मे से एक कोइ एक फेज मे फल्ट आता हे तो बाँकी दो फेजो को उपयोग कर सकते हे ।और तिनो फेजोमे किसी टाइम फल्ट चेन्ज होता हे तो क्या हम सहि फेजको उपयोगमे ले सकते हे ।
Input में फेज फल्ट जाने पर किसी भी फेज का output नहीं मिलेगा .
sir, is it possible protect the load when neutral failure 3 phase 4 wire system
Yes.
@@ElectricalHome kindly make a video sir
लेकिन सर आपणे रिले को फेज नही दिया है सीर्फ न्युट्रल दिया है।