Divide the 5500 watt MCB load so that the KWH MCB is safe and doesn't get damaged easily
Вставка
- Опубліковано 8 вер 2024
- assalamualaikum.
in this video I share about how to divide the 5500 watt mcb load so that the kwh mcb is safe and doesn't get damaged quickly, here we can calculate the mcb amperage with the formula I = P/V
so that it is easy to determine and divide the load of the 5500 watt mcb so that the kwh mcb is safe from being damaged quickly.
-------------------------------------------------- ---------------------------
For those of you who have taken the time to watch this video, I thank you very much. 👍🤝
Don't forget to "LIKE" this video....!! 👍
Include your comments in the comments column if you have any questions..??
And don't forget to "SUBSCRIBE" this channel...!!
You can share this video with your friends, OK...!!
🙏🙏🙏
--------------------------👇👇👇
My channel link;
/ ilmulistrik
Facebook ; / ilmulistrik
Instagram ; / ilmu_listrik
TikTok ; tiktok.com/@ilmu_listrik
-------------------------------------------------- ---
#divideloadmcb
#dividegroupingmcb
#mcbgroup division
#SCIENCE
ahirnya muncul jugak tutorial ini, karena masih banyak yg belum faham, thanks
Channel yg selalu shering tentang ilmu kelistrikan...tetap semangat.trs berkarya dan sukses selalu sobat..aamin
terima kasih dukungannya gus 🙏🤝
Ini Konten Sangat Luar Biasa.... 🙏 👍👍👍👍
trimakasih bos .smoga bermanfaat buat semua. berkah slalu
terima kasih kembali 🤝
Siap bang
ijin nyimak kak 🙏🏻
Mau tanya bg kenapa kabel awal 5500 pakai kbl 3 kn klu voucher boros klu pakai groud?
bg mau tanya, apabila Arus total dari ke tiga MCB Group tersebut mengalami arus berlebih, bagaimana?
Contoh :
Groub 1 = MCB 20 A, Beban 10 A
Groub 2 = MCB 20 A, Beban 10 A
Groub 3 = MCB 20 A, Beban 8 A
Jadi dari 3 Groub MCB tdi memiliki arus Total 28A, mungkin yang MCB Groub tidak trip, sedangkan pada mcb kwh hanya 25 A, apakah akan tetep Trip, untuk MCB KWH bg?
Terima Kasih 🙏🙏🙏
iya mcb kwh yg akan trip
Mas mau tanya,,daya 5500 w standarnya menggunakan kabel sr ukuran berapa? Soalnya untuk kebutuhan kandang ayam close pake blower 1100 Watt 2 buah ,, terimakasih
untuk 1 phase, kabel jalur utama dan jalur ke stop kontak pakai kabel ukuran 2,5mm²
untuk lampu bisa pakai ukuran 1,5mm²
Maksud saya kabel sr dari tiang listrik ke spido meter ms,,,pae yg u 2 × 16 atau 2× 25 ?
pakai 2 x 16 mm² sudah bagus bang 👍
Oke siap ,, terima Mase ,, salam sukses 👍👍🙏🙏
Gan, ane pake KwH dari PLN 5500 Va, dikasih MCB bawaan 25A..
Dari situ pake kabel NYM 3x6 ke MCB box, tapi MCB pertamanya bukan 25A.. Melainkan 16A.. Itu bisa gak ya?
Om numpang tanya mengenai pembagian MCB, saya menggukan daya 5500VA untuk kebutuhan bengkel menghidupkan 2 buah mesin masing2 1000W, dan 2 buah kompresor masing2 1500W, sebaiknya bagimana pembagian MCB yg tepat? dan berapa ukuran kabel yg tepat untuk setian stop kontak? terimakasih..
mesin 1000watt pakai mcb 6a
kompresor 1500watt pakai mcb 10a
untuk grup nya 6a, 6a, 10a, 10a
pakai kabel 3 x 2,5mm² sudah cukup untuk setiap stok kontak
ok terimakasih om untuk jawabannya.. sukses selalu!
sama sama bang
salam sukses selalu
Bang mau nanya, kan beban maksimal 25A utk 5500va, tapi kenapa MCB pembagi ada 3 yg totally menjadi 3x2= 60ampre, bukankah itu SDH melebihi beban maksimal dari 5500va ini bang ? Terimakasih
kalau dihitung memang over kapasitas, tp instalasi kan sudah terbagi 3 grup, toh gak mungkin juga di salah satu atau kedua grup pemakaian full sampai 20a, itu asumsi saya 🙏
memang kalau sesuai pembagian seharusnya 10a, 10a, 6a (ini yg pas)
Info bang klo buat daya 7000 pake MCB yg brapa Amper🙏
mcb 35A bang
Kalao itu kwhmeternya 5500 tros. Kalao pake rcbo nya berapa Amper bang punya saya rcbonya 35amper tapi ini udah 2hari amangak bos🙏🙏🙏🙏🙏🙏🙏
Tros punya saya rcbonya 35amper tros ncbnya 10amper satu tros 6 .Amper tiga tros 4amper 3biji aman gak bos ini udah duahari aman
pak listrik saya 5500 VA, kalo dibagi jadi 10 dan 16 bisa ga ya, ngga pake mcb utama, MCB 1 10A, MCB 2 16A, yang 10A bebannya sedikit dibanding yang ke2, jadi ngga bisa dituker urutannya
bisa bang, pasang mcb 10a dan mcb 16a
maaf mas mau nanya itu di kwh kan 25 amper klo di samakan 25 amper yang tu gk bahaya ya mas?
kalau disamakan gak papa 👌
penting tidak lebih besar dari mcb kwh
@@ILMULISTRIK trima kasih infonya mas.
Om mau tnya, sy pakai listrik 5.500VA
Tetapi untuk MCB di dalam rumah saya bagi menjadi 2 dan saya memakai MCB 25amper 2 unit, apakah itu aman?
lebih baik pakai mcb16a dan 10a
kalau 25a dan 25a, jika ada beban lebih yg ngejeglek bukan mcb grup, tapi mcb meteran
@@ILMULISTRIK bearti sy ganti lg dengan MCB yg om sarankan 10 dan 16 ya. ADa cara lain kah? Ataukah saya bisa pakai 1 MCB aja dgn 25amper dan yang satu lg saya lepas. Gimana om? Mohon sarannya
ketimbang beli lagi kan harus nambah biaya
betul tuh bisa dipakai 1 grup mcb saja 👍
@@ILMULISTRIK siap om, thnks masukannya
semoga bermanfaat 🙏
Om berarti kalau listrik 5500 va, dan dibagi jadi 2 atau 3 grup, gak perlu pakai kabel 4 mm semua ya?
kabel 4mm untuk kabel U/podeng
instalasi rumah cukup pakai ukuran 2,5mm
@@ILMULISTRIK kabel u/podeng itu maksdunya gmn ya ?
@lutviezhakaria6043 kabel dari kwh meter ke mcb dalam
Kabel utama dari mcb utama ke mcb grup pake ukuran berapa mas minimal?
bagusnya pakai 2,5mm²
biar gak panas kalau pakai ukuran yg kecil
Saran ukuran kabel ntuk 5500 makasih🙏
untuk jalur apa dulu nih bang..?
penentuan ukuran kabel harus sesuai dengan beban yg dilayani
kalau hanya untuk jalur / line utama dan jalur stopkontak pakai 2,5mm² sudah cukup
@@ILMULISTRIK 3mcb yg satu kebutuhan lampu sedikit dan 2 mcb ntuk standar mesin las tig dan 2.pk Kompresor
mesin las tig berapa watt tu bang..?
@@ILMULISTRIK tig daiden 200
mesin las tig daiden 200 itu sekitar 900watt kalau standby, tp saat kondisi pengelasan bisa naik 2x lipat
pakai mcb 10a untuk mesin las
mcb 10a untuk kompresor
mcb 4a untuk lampu
untuk kabel pakai 2,5mm²
daya 5500, pake kabel NYA 2,5 mm2 aman ga bang?
sdh dibagi
MCB Stop kontak 10 A, kabel NYA 2,5 mm2
MCB AC 10 A, kabel NYA 2,5 mm2
MCB Saklar 6A, Kabel NYA 1,5 mm2
sudah mantap tuh bang, ukuran kabel yg dipakai sudah pas, terbaik 👍
Bang mau nanya
kalau pakai 5500 va untuk jalur ke lampu pakai kabel 2x1,5 masih aman gak bang? Terimakasih 🙏🙏🙏🙏
untuk jalur lampu aman masseh
Makasih bang ilmunya, sangat bermanfaat
Semoga cenelnya lebih berkembang lagi🙏🙏🙏
@setya305 aamiin 🤲🏼
terima kasih do’a dan dukungannya
mas kwh meteran sy 5500 mcb dlm sy bagi 2 jd 16A-16A sy pakai langsung tanpa mcb 25A ,amankah? Atau ada solusi lain mas?
masih aman bang