Leshiy 2 regulator rebuild UK part 2

Поділитися
Вставка
  • Опубліковано 18 лис 2024

КОМЕНТАРІ • 27

  • @pyug17
    @pyug17 3 роки тому

    Brilliant. Great results.
    Time to dig out my autosol & have a go myself.

  • @ken244
    @ken244 3 роки тому

    great video, love the gauge on the gun and the fill tester dodad you made.

    • @sub12airgunners
      @sub12airgunners  3 роки тому

      Thanks glad you enjoyed it. Thanks for watching.

  • @ahuman5456
    @ahuman5456 3 роки тому

    Another highly informative video. Could the discrepancy have been caused by the regulator settling under pressure?

    • @sub12airgunners
      @sub12airgunners  3 роки тому +2

      Very possibly yes, I have noticed a very predictable pattern in that the first and second shot from the magazine are high and low respectively, then it gets very consistent, so I am thinking reducing the plenum volume is defiantly on the cards next as I don't think the regulator is resetting properly as it settles. Thanks for watching.

  • @gm0hzi
    @gm0hzi 3 роки тому

    nice increase from a simple reg rebuild , have you thought about reducing the plenum volume by machining inserts for it ? , wonder how that would affect consistency

    • @sub12airgunners
      @sub12airgunners  3 роки тому +2

      Good question, yep 42cc of plenum volume is far too much for sub 12 use, so I plan on making a Delrin plug to reduce the volume to around 10-15cc this should help with consistency and improve the shot count. Thanks for watching 👍

  • @jeffhello1444
    @jeffhello1444 3 роки тому

    Nice, and it should get a little better as the reg beds in 👍👍

    • @sub12airgunners
      @sub12airgunners  3 роки тому

      Yep more testing and fiddling on the way. 👍

  • @leec8592
    @leec8592 3 роки тому

    Great video buddy!
    Thanks for posting

  • @fransiapotiente6618
    @fransiapotiente6618 3 роки тому

    Nice video! Where can I find a spare regulator for this gun?

    • @sub12airgunners
      @sub12airgunners  3 роки тому

      Not sure, you could try Edgun west or directly contacting Edgun in russia. 👍

    • @fransiapotiente6618
      @fransiapotiente6618 3 роки тому

      @@sub12airgunners ok thanks, i try

  • @benytanaya7221
    @benytanaya7221 3 роки тому

    👍👍👍👍👍

  • @vdml
    @vdml 3 роки тому

    Can I just fire until the pressure drop to where reg doesn't open to know the reg setting pressure?

    • @sub12airgunners
      @sub12airgunners  3 роки тому +2

      You can do that to get a very rough idea but, my rifle started to drop power a little before reaching the reg set point, I.e when the reg is set at 70 bar the power started to drop at 90 bar on the rear gauge, so you would have to be mindful of this.

  • @mrshoto9035
    @mrshoto9035 3 роки тому

    Good work ~ Thanks for your efforts. 🥇👍

  • @rafarodmir7492
    @rafarodmir7492 3 роки тому

    Really well explained, thanks!!!

  • @philipwells2793
    @philipwells2793 3 роки тому

    Thank you

  • @lisawood516
    @lisawood516 3 роки тому

    Good results. 👍

  • @ken244
    @ken244 3 роки тому

    35 bar per 1/4 turn

    • @sub12airgunners
      @sub12airgunners  3 роки тому +1

      Yep its quite repeatable, Thanks for watching.