3rd Big Mistake Dc inverter Air Conditioner Showing E5 Error | Orient Inverter AC E5 error code

Поділитися
Вставка
  • Опубліковано 16 жов 2024
  • 💡 Join Us On Patreon 👉 bit.ly/3vMga6S
    💡 Subscribe To Get All FREE Videos 👉 bit.ly/3MMozxd
    _____________________________________________________________
    💡 Subscribe Forever Tech Shorts Channel 👉 bit.ly/3gL5vQz
    💡 Subscribe to the English Channel 👉 bit.ly/3pzBLvh
    Social Media Links
    💡 Facebook 👉 bit.ly/3hTPHvY
    💡 Instagram 👉 bit.ly/3oJcwDm
    💡 Twitter 👉 bit.ly/3atkbRl 3rd Big Mistake Dc inverter Air Conditioner Showing E5 Error | Orient Inverter AC E5 error code
    Subscribe ▶ bit.ly/2Xj8JkN
    Subscribe 2nd Channel ▶ bit.ly/336lCSz
    Popular Video ▶ bit.ly/3nGjlGH
    Previous Video ▶ bit.ly/3cefM6w
    Forever Tech Shorts Channel ▶ bit.ly/3gL5vQz
    Hello Guys It is Great to see you again on our channel forever tech we hope you always support our efforts because we can not run this channel with out your support good luck and have a nice day.
    About this video
    In this video i am gonna repair dc inverter ac pcb and the big which was made but you have to avoid it while repairing the pcb and the pcb was of orient dc inverter and how to prevent it and due to this mistake the air conditioner starts showing e5 error code on the display of the ac so you have to avoid the mistake when repairing ot installing the inverter ac and like share with others and don't forget to subscribe.
    Social Media Link
    ..................................................................................
    Facebook ▶bit.ly/36FbFgP
    .....................................................................
    Instagram ▶bit.ly/3oJcwDm
    ....................................................................
    Twitter ▶ bit.ly/3atkbRl
    ....................................................................
    Our Other Videos Playlist
    Air Conditioner Basics/ Hvac basics Playlist
    ▶ bit.ly/36GtfRQ
    Compressor Testing Playlist
    ▶ bit.ly/36JgkOZ
    Automatic Washing Machine Repair Tricks Playlist
    ▶ bit.ly/3rj7Dmc
    Dc Inverter Air Conditioners PCB Repairing Tips Playlist
    ▶ bit.ly/2YPIrr7
    Electronic Component Testing
    ▶ bit.ly/39MQdbP
    Washing Machine Basics
    ▶ bit.ly/3t9AGt7
    Refrigerator Faults and problems
    ▶ bit.ly/3tcYE6D
    .......................................................................
    #forevertech #inverterac #orient #e5errorcode #error #code #ac #hvac #airconditoner #bigmistake

КОМЕНТАРІ • 60

  • @ishfaqkhanshinwari8304
    @ishfaqkhanshinwari8304 3 роки тому +1

    Thanks a lot.your video is very useful.today I maked my inverter Ac circuit.IPM problem I chang it now Ac working perfect .

  • @abhichauhan7422
    @abhichauhan7422 3 роки тому +2

    Nice explain sir
    Sir igbt kis no. Ka laga sakte hai

  • @princeprince6284
    @princeprince6284 7 місяців тому

    Jazak Allah sir ❤❤

  • @salimullahkhan5594
    @salimullahkhan5594 3 роки тому

    آپ کا ویڈیو بہت اچھا ہے

  • @uzershaikh6730
    @uzershaikh6730 3 роки тому +1

    Masaallah very informative video .Sir ye pcb mein jo power diode laga huva hai ye number hai uska byc30w-600p, ye mil nahi raha hai to konsa laga sakte hai plz sir

  • @AkhileshSingh-mz5tx
    @AkhileshSingh-mz5tx 2 роки тому

    Sir aapka shop kaha hai

  • @susantaatha6468
    @susantaatha6468 3 роки тому

    Very good advice.

  • @arshadbilal109
    @arshadbilal109 3 роки тому

    good very good
    i love you sir

  • @waqasaslam69
    @waqasaslam69 3 роки тому

    Sir very impresiv

  • @w11007
    @w11007 2 роки тому

    Asak, Very informative Vdo .... meray Orient inverter AC mai ek Dafa E5 ka error aya tha magar phir woh disappear ho gaya aur AC sahi cooling karany laga .. kiya mai AC use karta Rahun ya kisee ko dokhaon ... Ajj barish bhi kafi huwi thee aur uss mai AC use ho raha tha

    • @prince-khan55
      @prince-khan55 9 місяців тому

      @w11007 apne phr ac check kraya tha k wesy he sahi chal rha??? reply

  • @malikmoosa.khokar6709
    @malikmoosa.khokar6709 2 роки тому

    Nice sir

  • @arelectronics4639
    @arelectronics4639 3 роки тому

    Sir mein nay issi Circuit k baray mein Comment kiyaa thaa k 3 ya 4 Amper pay jaa k Tripp kr jata haa yanni k kit load nhi leti iss per video bnaa dein Shukriyaa ❣️

  • @laxmikumkum5817
    @laxmikumkum5817 3 роки тому

    Good information

  • @ohmbtr8746
    @ohmbtr8746 3 роки тому +1

    Thank you sir .aapka explaination is very good .But one thing I want to say is .You don"t nred to say again and again for bell icoin to press .its distrub when we concentrate your video .because your videos are very good any way so people will like and share too.please change this one thing please.

  • @informativeone1050
    @informativeone1050 3 роки тому

    Sir pcb k Jo khrb components hotay hai wo ap Kaha say buy krtay hai .. or agr igbt same number ki na milay tu kia kisi or number ki b lag sakti hai Kia.. sir plz is pr b videos Bana dain

  • @abdulmajeedvk3471
    @abdulmajeedvk3471 3 роки тому

    Very good

  • @SRTechnicalBD5763
    @SRTechnicalBD5763 3 роки тому +1

    Sir acki pcb brod ka all sarket fangtion daygam to pactical sarket dekna cataho, or kiss jagase kitna valo ki component lagegi

  • @mohd.rashid5255
    @mohd.rashid5255 3 роки тому

    Sir ye kit lloyd ki ac me bhi hai sir kya orient or lloyd ac ak hi hai sir meri pcb me bhi yehi problem hai sir

  • @KSKGARAGE-o4o
    @KSKGARAGE-o4o 8 місяців тому +1

    ❤❤❤❤

  • @manikandank4238
    @manikandank4238 2 роки тому

    Sir I changed igbt after 5v short what is the problem I don't know I am watching ur every video

  • @symstech
    @symstech 3 роки тому +2

    Good sir first view first comment

  • @mohammedshamshad6116
    @mohammedshamshad6116 3 роки тому

    Sir CH82 ka kya problem hai lg package Ac me

  • @krishnachand8203
    @krishnachand8203 3 роки тому

    Sir is pcb ka ptc mz 47 r a kharap ho to kya hoga

  • @mateencric
    @mateencric 3 роки тому +1

    Ye khrab ho jaie to kitne tk theek ho jata ager fuse theek ho to

  • @hamzaofficial313
    @hamzaofficial313 3 роки тому

    repairing k liye address bta dein kha le kr ao sir

  • @krishnachand8203
    @krishnachand8203 3 роки тому

    Sir same pcb hai l1error aar hai indoor chalta par outdoor me halka kit kit ki awaz aati hai or odu fan comp kuch bhi nahi chalta odu pcb ka led 3 continue 1,2 blink karta rehta h

    • @bhaveshdiyora6103
      @bhaveshdiyora6103 3 роки тому

      Mere ko bhi yahi probelm hai aapko
      Solution mila ho to bataiye

  • @sunilkumarbatcha5129
    @sunilkumarbatcha5129 2 роки тому

    Sir IPM चाहिए मुझे कहां से मिलेंगे क्योकि मै बहुत परेशान हो गया हुं इनवर्टर AC की PCB के पार्ट ढूँढते हुए PLEASE बताईये मुझे ये हरियाणा मे कहां से मिल सकता है

  • @arifmushtaq9136
    @arifmushtaq9136 4 місяці тому

    Bager outer pcb circuitt k E5 kese overcome karen

  • @hvaclearningsolutions4051
    @hvaclearningsolutions4051 2 роки тому

    Sar brig chang kya h lakin jb compressor lord p jata h to braker trip ho jata h or brig jal jata h

  • @alfaaircoolingsystems8742
    @alfaaircoolingsystems8742 3 роки тому +1

    Sir daikin invenetar ac out door 1minit on hokar out door fan our compressor off hogatha hai kuch rezan boliyea

    • @ForeverTechHindi
      @ForeverTechHindi  3 роки тому

      gas pressure check karian agar pressure suction pressure 175 psi hona chayee agar kam ho ga tu kam nahi karee ga 100 psi say 130 psi per band ho jayee ga

  • @devendrasirvi7381
    @devendrasirvi7381 2 роки тому

    Igbt kaha se milegi

  • @shahrukkhan2602
    @shahrukkhan2602 Рік тому

    Igbt number kya hai ???

  • @praveenpitamber9974
    @praveenpitamber9974 3 роки тому

    What no of IGBT used in this orinet PCB

  • @arsaha1797
    @arsaha1797 3 роки тому

    Panasonic inverter air conditioner model cu-k24pkf-5 error H11 what is the problem

  • @swamybommisetty431
    @swamybommisetty431 2 роки тому

    Sir loyed e5 sir pls

  • @MuhammadBilal-tg6qq
    @MuhammadBilal-tg6qq 2 роки тому

    sir g igbt ka number bata dan plz

  • @imrankhankhan3671
    @imrankhankhan3671 2 роки тому

    میرے پاس ایک انورٹر اے سی ھے انڈور تو چل رہا ہے آؤٹ ڈور نہیں چل رہا نہ کوئی الارم ہے نا کوئی نمبر آ رہا ہے اورین کا ایسی ہے

  • @manisweet917
    @manisweet917 3 роки тому

    Sir g dcanwaltar ac ampar 2 bad ho jata h

  • @jayeshbarhate3835
    @jayeshbarhate3835 2 роки тому

    Sir meko class
    Karna hai

  • @purshottamsalesandservice0812
    @purshottamsalesandservice0812 3 роки тому

    How to repair F1 error

  • @muhammadyousaf1877
    @muhammadyousaf1877 3 роки тому

    My orient dc inverter cooling nahi dy raha work shop address foon#

  • @krishnachand8203
    @krishnachand8203 3 роки тому

    Kabhi kabhi chalta hai per 10,15 minutes ke baad l1aajata h

  • @ahavazkazi1268
    @ahavazkazi1268 2 роки тому

    e5 error ah raha hai thn phr gayeb hogaya after i turned it off nd on again