Calculating Superheat and Subcooling

Поділитися
Вставка
  • Опубліковано 10 лип 2011
  • A demonstration on how to manually calculate superheat and subcooling vs. how to use the testo 550 to calculate superheat and subcooling.

КОМЕНТАРІ • 34

  • @iago1779
    @iago1779 12 років тому +1

    Hey thanks for the video TestoInstrument guy., You explain this so much better than any video ive seen on youtube or in class.

  • @gtownhvac1640
    @gtownhvac1640 6 років тому

    I see u video 10 times thanks a lot

  • @jimbola77
    @jimbola77 7 років тому

    love it got to get me a set beat's ol scool analogs yess wonderful time saver no calculating or error's!!!

  • @TestoInstruments
    @TestoInstruments  13 років тому

    @d1g1man I'm not sure off the top of my head, but I will certainly find out for you! Thanks for your note!

  • @TestoInstruments
    @TestoInstruments  13 років тому

    I'm not sure off the top of my head, but I will certainly find out for you! Thanks for your note!

  • @joemcorbett
    @joemcorbett 9 років тому +2

    FYI there is a temperature pressure chart on your gages.

  • @johnnorris4618
    @johnnorris4618 11 років тому

    question, when you did superheat in analog your SH was 8 and SubC was 8 with your meter it SH was @ 16 and SubC was @ 8 is the meter off? of did u mis calculate?

  • @ocdaub
    @ocdaub 11 років тому

    Hey testo guy I liked the video you put out! I was curious if there is a way to get access to the work sheet you have?

  • @420boys89
    @420boys89 11 років тому

    what didital gauges where you susing to find subcooling?

  • @DaneStolthed
    @DaneStolthed 11 років тому

    Sorry I'm new at this and my questions may seem redundant...
    So superheat and subcooling range is just the difference between saturation temp and outside line temp?
    Is the range required for superheat and subcooling always going to be 9-12 degrees temp difference between saturation temp and outside line temp?
    When charging a system is the idea to try to get the saturation temp and outside line temp to be within 9-12 degrees of each other?

  • @jebickerssr
    @jebickerssr 11 років тому

    Testo offer two versions of the testo 550, a basic kit of meter and a clamp probe for $299 MSRP and a Deluxe Kit with meter, two clamp probes, and a carrying case for $399 MSRP. Contact your local wholesaler or favorite internet reseller, as they have these on sale. Testo is running a $75 mail-in rebate when you purchase the new t552 Digital Vacuum Gauge and any one of the Testo manifolds.

  • @loanhuynh9532
    @loanhuynh9532 5 років тому

    What is happen superheat and subcooling different for the analog and digital measurements and i had the same testo. i have to use analog.

  • @frandelo
    @frandelo 11 років тому

    Hey Sir, just a question, please. What about weather? Does it affect superheat calculation? Is it important to regard indoor temperatura before calculating superheat? Should superheat be calculated on sunny day or it's better on winter day? What would you recommemd me? Thanks a lot.

  • @anthonysandoval965
    @anthonysandoval965 5 років тому

    Where can I get that work sheet your recording on sir????

  • @fudogchomp
    @fudogchomp 11 років тому

    Wow nice, how much does this meter go for??

  • @jebickerssr
    @jebickerssr 11 років тому

    Superheat calculation is what is happening in the system. The target superheat calcuation is impacted by the weather. In the May 2006 issue of Contracting Business the article, Superheat: The Best Way to Tune an Air Conditioning System provides a good explanation of these. I tried to post the link, but I'm getting an error.

  • @mikeperry6528
    @mikeperry6528 2 роки тому

    What sheets do you use? I really would like a copy of those.

  • @abmvp11
    @abmvp11 11 років тому

    Can you scan that Calculation Sheet and upload on your website for download.
    I do ref. charges daily and could use a tool like this. Please look into it.

  • @jimford01
    @jimford01 10 років тому +3

    Why was superheat and subcooling different for the analog and digital measurements
    Was this the same unit

  • @slam223
    @slam223 4 роки тому

    Thanks sir

  • @andycensus
    @andycensus 11 років тому

    I did a Google search for "hvac job site calculation sheet pdf" and I found the form you can use. I tried to post the site here and youtube would not let me - I hope this helps

  • @Electric6869
    @Electric6869 10 років тому

    as well but if the superheater is correct or not should make a chart that indicates the superheater is correct. because they do not save if you need more refrigerant charge or remove refrigerant charge.

  • @MrWwoww123
    @MrWwoww123 9 років тому

    May I have a pdf for those service sheets you write on? They will help me in school greatly :)

  • @ZuffaLtdDanaWhite
    @ZuffaLtdDanaWhite 12 років тому

    Testo 905-T2: The instrument used for sensible heat measurements

  • @TestoInstruments
    @TestoInstruments  12 років тому

    I'm fairly certain the model # is 905

  • @Chris-H00
    @Chris-H00 9 років тому

    How do you get the manufacture literature.

    • @TestoInstruments
      @TestoInstruments  9 років тому

      Chris H, you can go to www.testo.com/product/0563+1550/testo-550-Digital-manifold-kit and click the green request more info button.

  • @hatprick
    @hatprick 10 років тому

    compress ration is 3.5 to1

  • @jjenson2006
    @jjenson2006 11 років тому

    You don't need a chart. Those temperatures are right on your gauges.

  • @jjenson2006
    @jjenson2006 11 років тому

    Look on your gauges, they are already on there.

  • @Jmunoz1675
    @Jmunoz1675 11 років тому

    Don't guess! Calculate...

  • @hatprick
    @hatprick 10 років тому

    low side pressure is to high

    • @kaloiankrastev6851
      @kaloiankrastev6851 8 років тому

      +hatprick i think that too... but maybe is normal for 410A