Case Study 2: Flash Fire in Pontoon Tank

Поділитися
Вставка
  • Опубліковано 7 вер 2024

КОМЕНТАРІ • 13

  • @pardeepsharma6808
    @pardeepsharma6808 3 роки тому +2

    very usefull in industries as well as in daily life

  • @emmanuellim155
    @emmanuellim155 3 роки тому +2

    Educational, well done 👍🏻

  • @Rai0179
    @Rai0179 4 роки тому +4

    Mixing should be done on the main deck not inside the space ; Flame Proof Lighting should be used not normal lightning.

  • @OJD-fy6sq
    @OJD-fy6sq 2 роки тому +1

    How did flammable gasses accumulate and go unnoticed if they where doing regular gas checks?

    • @moonlightwolf
      @moonlightwolf Рік тому +4

      The device used for the gas checks prior to entry didn't measure the flammable vapours. It was looking at gasses like CO, oxygen, and likely nitrogen

    • @temasek65
      @temasek65 Рік тому +2

      Gas check done at entry point. But not done when paint mixing and drying inside confined space. If gas check done during this activity the flammable LEL reading would have been detected by a multi gas meter. Forced ventilation used was not strong enough to counter the flammable gas accumulation in the confined space.

  • @mhine2119
    @mhine2119 3 роки тому +1

    so what conclusion can you give from that story?

    • @temasek65
      @temasek65 Рік тому +3

      Paint mixing should be done outside of the confined space. Explosion proof lighting should be used inside confined space. Forced ventilation can be done using a more powerful blower. Gas checks to be done on more regular basis and noting when painting is in progress. A workmen inside confined space space should wear a clip on gas detector that can warn of flammable gas buildup.

    • @haydaryahya7807
      @haydaryahya7807 11 місяців тому

      thankyou lo info e
      @@temasek65

  • @sureshs9259
    @sureshs9259 Рік тому +1

    Where was the incident happened?

    • @Xenoforge78
      @Xenoforge78 Рік тому +1

      Does it matter?

    • @israelCommitsGenocide
      @israelCommitsGenocide Рік тому +2

      yes it does matter, the slave class has a right to know who fucked up.

    • @thedolphin5428
      @thedolphin5428 Рік тому

      Why are all the workers black? Is it because:
      * the accident occurred in Nigeria?
      * the animators think only black people could be so stupid?
      * the animators are so WOKE they figure that blacks should be depicted 100% more than blacks?