Local Breaker Backup (LBB) | Breaker Failure Relay (50BF)

Поділитися
Вставка
  • Опубліковано 21 жов 2024
  • Local Breaker Backup (LBB) or Breaker Failure Relay (50BF)
    Protection Operate for the fault clearance of a system by tripping other circuit breakers when the related circuit breaker fail to operate.

КОМЕНТАРІ • 51

  • @anbur9568
    @anbur9568 5 місяців тому +1

    ❤extraordinary knowledge sharing..keep post videos busbar protection,differential,ref etc

  • @petarsimic2303
    @petarsimic2303 4 роки тому +2

    So far best relay protection channel on yt! Thank you for effort you put into videos Barani, We appreciate it!

  • @simonbenjamin7917
    @simonbenjamin7917 4 роки тому +1

    I have really enjoyed the video. Especially the LBBP for 1&1/2 Breaker Scheme. it was on point

  • @jamieroberts8902
    @jamieroberts8902 2 роки тому +1

    Lots of examples, very helpful! Thank you 🙏

  • @sivananthambalasubramanian1202
    @sivananthambalasubramanian1202 4 роки тому +2

    Nice presentation Barani sir. Thanks

  • @alishafi9272
    @alishafi9272 3 роки тому +1

    Appreciate your efforts sir. Learned alot.

  • @gharikrishna2280
    @gharikrishna2280 4 місяці тому +1

    While doing protection checks on down stream relay it's breaker is in already tripped condition any fault operated in the same relay in this scenario is LBB operation will occur in the up stream breaker

  • @SunilSingh-uy2re
    @SunilSingh-uy2re 2 роки тому +1

    In your video with dual busbar single breaker scheme both of the bus sections are connected via bus coupler. Bus coupler is in ON state but you said breaker of the particular bus section will trip !! How ?

    • @baranitech1026
      @baranitech1026  2 роки тому

      please tell me at which timing of this video

  • @PLAYWITHPHYSICS-s9l
    @PLAYWITHPHYSICS-s9l 8 місяців тому +1

    Very good nice explanation

  • @mohammednaveedhs4058
    @mohammednaveedhs4058 4 роки тому +1

    Sir finally you made this video thank you sir another request 3- phase transformer stability and 1-phase transformer stability. In traction sites we are using 1-phase transformer.plz make a video on this

  • @dittikatisatish4239
    @dittikatisatish4239 4 роки тому +1

    Hi sir thak you for your valuable videos and im having one doubt in this video in 1and half breaker system you have explained if main breaker fais to trip but my doubt is what if a tie breaker fails to trip then what will be sequence of operation in lbb protection..?

  • @kannirajulu
    @kannirajulu 3 роки тому +1

    Thank u for sharing knowledge

    • @baranitech1026
      @baranitech1026  3 роки тому

      most welcome

    • @kannirajulu
      @kannirajulu 3 роки тому

      @@baranitech1026 bharani sir,am working on sel487B,can u help in lbb configuration, rajesh134@gmail.com

    • @baranitech1026
      @baranitech1026  3 роки тому

      @@kannirajulu chat.whatsapp.com/EwWBppukxNTIoDJAE6e1NU you can post your doubt over here . on sel i am not much familiar

  • @meghanasr3098
    @meghanasr3098 3 місяці тому +1

    Sir do the ABB relay protection testing videos

  • @sivananthambalasubramanian1202
    @sivananthambalasubramanian1202 4 роки тому +1

    09.45 sir, why should the OG 1 send LBB initiation to remote end ss?

    • @baranitech1026
      @baranitech1026  4 роки тому

      it will trip remote end breaker for that line.

  • @aeerdkptcl4017
    @aeerdkptcl4017 2 роки тому +1

    Excellent sir.
    Please explain binary inputs
    GOOSE signals

  • @sameer81kulu
    @sameer81kulu Рік тому

    breaker failure is on buscoupler cb in double bus scheme then which cbs it should trip

  • @sajivs486
    @sajivs486 4 роки тому +1

    Thank you so much.

  • @Yusup_oke
    @Yusup_oke 4 роки тому +1

    Nice bro very clear, how about the sf6 2nd stage logic in GIS bro maybe you can create the video also.

  • @himanshu2232
    @himanshu2232 4 роки тому +2

    Nice vedio sir.👍👍👍👍👍

  • @mr.biplob3795
    @mr.biplob3795 4 роки тому +1

    Busbar stability how to injection Primary setup & secondary setup as well as how to check T protection,what is the arrangement for one and half scheme primary &secondary, please sir one tutorial we want from you side.

  • @bikramdas9770
    @bikramdas9770 4 роки тому +1

    Thanks

  • @sandeepramkumar7503
    @sandeepramkumar7503 4 роки тому +1

    Thanks sir

  • @vinoddas8773
    @vinoddas8773 4 роки тому +1

    Kindly make a video for Pole slip protection of generator....

  • @rohiths5987
    @rohiths5987 3 роки тому +1

    Sir please mention your email id I need to solve my doudts on Protection on 400 KV One and Half scheme and 220 KV Double main transfer

  • @AkashSingh-br4yp
    @AkashSingh-br4yp 4 місяці тому +1

    I am not satisfied this vedio
    Itna ghuma rhe ho ek line ka ans he

    • @baranitech1026
      @baranitech1026  4 місяці тому

      sorry if i am not satisfied . i will try to make other better video thank you

  • @pratibhaprajapati7984
    @pratibhaprajapati7984 8 місяців тому +1

    thanks