1 kw pr lazmi 25mm wire use kare Agher load 800watt ho tu Kisi wajah se load battery pr shift ho jahe tu battery pr almost 90amp load ah jahta hai, Kia 25mm se Kam cable chal sakti hai
Sir mene recently jinko 585w ki 10 plates lagai hain 10mm ki solar wire ke sath 5,5 ki strings bnake inverter hath ka bna hua local ha bina batteries or wapda ke but jese he ispe 1.5ton ka DC inverter AC chalata hn trip krjata ha inverter zada ampere generate ni krpara ha kya krun
Agr manual pe mention kea gye wire area se zaida area ke ham wire add kren ya us se next wali use kren jaise 6mm² ke jagah 8mm² to us se power loss ya koi msla to nahi ho ga Or ik video bnaen wire area k hisab se k kitne current flow ya voltage k lea kitne mm² ke cable istemal kren to best he awg or swg dono hisab me, ta k load k hisab se wire size nikal sken
Aoa sir. Thanks for making all the informative videos on YT regarding solar. Very helpful. Appreciate your efforts. I want to ask little thing if you can help me or make a video so others can also get some knowledge. I recently installed 2.5k inverex. And I want 1 room totally separated from solar system so I can use iron and heavy load via tha room. That room have separate red and black wire and it is not touching anywhere. The problem I am facing is when I direct that room with wapda. The black wires gets connected to solar ground. My question is, is it OK if the ground wire is connected with source of wapda and source of solar? Please let me know soon thanks.
Distance from penal to inverter aprox 40 feets 2 penal 280 watts each is connected in series Individual penal generate current when short is 13 amp I uses 6 mm wire My problem is im getting only 2.3 ampere and 36 volts ans power is varies 80 to 120 watt only Please help me out of this problem
Sor Me 3.5kw Solar Panal Mea Wire 6mm use Ki Hai.Wsay Inveter Tk Ka 60gz Hai Kya sahi kiya Hai Ya nahi..... Q K 6mm ka Coil 25000 ka Mil Raha Hai Or Is Say jtna Zydia Upar Jy To Wsay
@@chaudhryasif8335 koi samaj nai i apki baat ki. Volts 1500 kesy ho sakty hain? Itny volts vo bhi 3.5 kva main? Or agar wire ki length ziada hai to voltage drop hoty hain or uska solution ziada panels lagana hota hai is k aliva to i think koi solution nai hai.
Walikomsalam AP k installer NY system wiring krty time ek wire common ke ho gee I Think Ku k solar system mein dono Phase ya to Wapda Sy aen ya fer inverter Sy aen ... Age ek phase inverter or second common ha to Wrong connection hota ha ..
@@technicalguidanceman 4kw ka inverex inverter and 24 v 100 ampere ki lithium ion battery ka set up 9 panel of 585 w Kay sath lagana chah Raha hun khi man Kia yeh sahi rahayga?
@@technicalguidancesir mai ny 575w 6 penal ky sath 10mm wire breaker tak lagi hy or zewnic 4.5 kv inverter mai choty conneters ki waja sy breaker sy inverter tak 4mm cable use kia hy 3 foot ye ki masla to nahi kary ga
Assalam o Alakam Main nay 10kw ka net metering lagwaya hay, Pl iss kay baray zra cable ki specification batta thain. Kitni honi chahiay. Inverter aur panels ka distance 25 feet hay, Sari cable 6mm use ki hay. Pl guide krain ham best performance kdsay lay szktay hain. Pl send your cell no. I want guidence from you. Thanks God bless you yo teach people.
One of the few channels where one can find real technical advice. Keep it up !.
Mene apnay 24V 3KVA UPS me 5 Meter 25mm flexible wire lagai hui he, or Alhamdulillah behtreen system chal raha he..
Thanks for very good and informative information 👍
Great content
Useful informations
❤ماشاءاللہ❤
Brother may U b blessed
Good bhi
Zabardast mashallah
very good dear.JAZAK ALLAH
آپ خود کہ رہے ہیں کہ کار خاںہ دار جو وایر بنا تے ہیں تو اسمیں گڑ بڑ کر جاتے ہیں تو آپ سے یہ پوچھنا ہے کہ قوم کیسے پاکستانی بنے گی اور پاکستانی اشیاء خریدے گی
Good ustaad
1 kw pr lazmi 25mm wire use kare
Agher load 800watt ho tu Kisi wajah se load battery pr shift ho jahe tu battery pr almost 90amp load ah jahta hai,
Kia 25mm se Kam cable chal sakti hai
good job jezak alla
Very good information. Thank you.
Nice information ❤❤❤
Sir mene recently jinko 585w ki 10 plates lagai hain 10mm ki solar wire ke sath 5,5 ki strings bnake inverter hath ka bna hua local ha bina batteries or wapda ke but jese he ispe 1.5ton ka DC inverter AC chalata hn trip krjata ha inverter zada ampere generate ni krpara ha kya krun
6mm or 12mm ki cable Hoti nhi ha
Available size 4mm 6mm 10mm 16mm 25mm35mm
اچھا
Good ❤
Excellent information
Ma aki scary videos dekhta hun,
Inverx 3 3.2 ma 450 volte tak penal series may lagany pr karab Hoga ya nahi rehnomai kary
Shukria
slaam
bhai koi company name hi bta dain jin ki wair gaij puri hoti he
Can we joint three or four
pieces of 10mm cable for battery
Mery pass 660 watt ki plates han en k 7 kitne amp ka charg controler lagay ga
Hamare pass 585 k 2 panels two panels hai parallel connection hai 60 mm ki tar hai 60 ft distance 6 mm ki tar hai
Mere inverter k manual pe 4mm2 cable likhi hui PV k sath. Inverter 4 KW ka he PV 6000 supported he
Agr manual pe mention kea gye wire area se zaida area ke ham wire add kren ya us se next wali use kren jaise 6mm² ke jagah 8mm² to us se power loss ya koi msla to nahi ho ga
Or ik video bnaen wire area k hisab se k kitne current flow ya voltage k lea kitne mm² ke cable istemal kren to best he awg or swg dono hisab me, ta k load k hisab se wire size nikal sken
Assalamualaikum bhai Kya AC aur DC ka koi 1 wire hai ke porye Ghar Mai wiring karye?
585 watt k 2 panal k Lia kitne mm ki wire use ho gi 35 feet distance
Aoa sir. Thanks for making all the informative videos on YT regarding solar. Very helpful. Appreciate your efforts. I want to ask little thing if you can help me or make a video so others can also get some knowledge. I recently installed 2.5k inverex. And I want 1 room totally separated from solar system so I can use iron and heavy load via tha room. That room have separate red and black wire and it is not touching anywhere. The problem I am facing is when I direct that room with wapda. The black wires gets connected to solar ground. My question is, is it OK if the ground wire is connected with source of wapda and source of solar? Please let me know soon thanks.
Keep Earth wire separate from wapda. Otherwise your meter will run like u using wapda.
Good
BHI sab 8mm KY Kon C company KY cabal achi Hoti Hain aur kaysy pata chlay Ga wo original Hain reply zourr Karin thanks
Good ustad ❤❤❤❤
What is sting pl explain
Good ustad❤❤❤
Can i make 2 strings of different watts in zievnix 62pv inverter
Distance from penal to inverter aprox 40 feets
2 penal 280 watts each is connected in series
Individual penal generate current when short is 13 amp
I uses 6 mm wire
My problem is im getting only 2.3 ampere and 36 volts ans power is varies 80 to 120 watt only
Please help me out of this problem
میں نے ایک میٹر تار بیٹری پر 16ایم ایم لگائی ہوئ ہے کیا درست ہے؟
Sir kis brand ki cable use kren
20ft k liye 12mm ok h ya ni
Sir 10 plates agar 580w k hoon to ajkal kitny watt milay gy
3.5 kv
Dear brother kon say area main kam kartay hain
Khanpur
خان پور کہاں ہے@@technicalguidance
District Rahim Yar Khan
app video may terminal voltage drop hony ka dikhany ka kaha tha lekin nahi dikhaya
Ok next video mai dikhaoun ga
Sor Me 3.5kw Solar Panal Mea Wire 6mm use Ki Hai.Wsay Inveter Tk Ka 60gz Hai Kya sahi kiya Hai Ya nahi.....
Q K 6mm ka Coil 25000 ka Mil Raha Hai Or Is Say jtna Zydia Upar Jy To Wsay
6mm behtreen hai apky setup k liye
Yr Battery Charging Or Load Sahi Nahi Chal Raha ????
@@TheHaamii
@@ahmedshaikh5467 kesy sahi nahi chal raha? Masla kia aa raha hai?
6kw ka setup bhi 6mm wire k sath behtreen chalta hai, apka to 3.5kw hai.
Bhai m ne 3kv ka lagaya hy 6mm lagi hy 95 fot lenth hy 1500 tak voltage deta hy us se oper jay tu drop kr deta h .kia masla h koi bata sakta h
@@chaudhryasif8335 koi samaj nai i apki baat ki. Volts 1500 kesy ho sakty hain? Itny volts vo bhi 3.5 kva main? Or agar wire ki length ziada hai to voltage drop hoty hain or uska solution ziada panels lagana hota hai is k aliva to i think koi solution nai hai.
❤
Assalamoalikum sir hum ny jab sy solar instal krwaya hy hamare kE meter pr revarce fase ke light on rehte hy please koi hal bata den
Walikomsalam
AP k installer NY system wiring krty time ek wire common ke ho gee I Think
Ku k solar system mein dono Phase ya to Wapda Sy aen ya fer inverter Sy aen ... Age ek phase inverter or second common ha to Wrong connection hota ha ..
Ap kay inverter ka Neutral common hai ap ke Wapda ya KE say Electrician say is ko sai karwain
Jazakallah sir Allah apko khush rakhy main check krwata hon please
To original ki kya pechan hai
👍
Ap Kis city man hotay han.
Khanpur katora Dist. Rahim Yar Khan
@@technicalguidanceman 4kw ka inverex inverter and 24 v 100 ampere ki lithium ion battery ka set up 9 panel of 585 w Kay sath lagana chah Raha hun khi man Kia yeh sahi rahayga?
Sir Sialkot installation kar do gai
Ji Zaroor
Contact us:
Name: Muhammad Tariq
Phone1: +923214510071
Phone2: +923438413955
10MM ki cable kitnay ki millay ge solar panel say inverter tak cable taqreeban 45 feet distance
Round about 150 Rs/Feet
@@technicalguidancesir mai ny 575w 6 penal ky sath 10mm wire breaker tak lagi hy or zewnic 4.5 kv inverter mai choty conneters ki waja sy breaker sy inverter tak 4mm cable use kia hy 3 foot ye ki masla to nahi kary ga
Not a problem
Sir. Ap se mashwara krna ho to kese kiya jaye?
03006715530 For Detailed Consultation Only WhatsApp Voice Message, Please Don't Call me.
25mmm ki wire😂😂😂😂 bhai 10 se 16 mm ki cable enough hoti hai solar panel k liye. Or battery k liye 25mm lagani chaiye.
25mm battery k lea bola he or agr capacity zaida ho to 32mm
Assalam o Alakam
Main nay 10kw ka net metering lagwaya hay, Pl iss kay baray zra cable ki specification batta thain.
Kitni honi chahiay.
Inverter aur panels ka distance 25 feet hay,
Sari cable 6mm use ki hay.
Pl guide krain ham best performance kdsay lay szktay hain.
Pl send your cell no.
I want guidence from you.
Thanks God bless you yo teach people.
Only WhatsApp
03006715530
0k
Contact number for installation in Lahore
Name: Muhammad Tariq Lahore
Phone1: +923214510071
Phone2: +923438413955
Organization: Global Solar Lahore
𝘚𝘪𝘳 𝘎 ❤ 𝘳𝘪𝘨𝘩𝘵
Assalamualaikum....sir apka whatsp number
03006715530 whatsapp par Voice message krain & please don't call me 🙏🏻بھائی کال نہ کیجئے گا