How to perform GMDSS Radio Batteries Annual Performance Test. | MF-HF Radio console | Back-up Power

Поділитися
Вставка
  • Опубліковано 12 гру 2024

КОМЕНТАРІ • 13

  • @hunskhant-xq7pv
    @hunskhant-xq7pv 11 місяців тому

    Ty for continuing education on board. Mabuhay mga ETO

  • @1000milesatsea
    @1000milesatsea 3 місяці тому

    Hi friend. tks for your video but the regulation for Annual capacity test that measures the capacity of the battery in Ampere hours. The battery should be replaced if its capacity is less than 80% of the rated capacity. so how do you demonstrate that only with voltage ?

  • @efnd7436
    @efnd7436 Рік тому +1

    My friend. How about the Ampere reading during test on load. How much the value to make the battery is good condition. Tks for reply

  • @romnicktabar2781
    @romnicktabar2781 Місяць тому

    So during the whole test.. You keep on pressing ptt??

  • @marksteventv4747
    @marksteventv4747 Рік тому

    sir ano yung reading s before and after sa amphire?

  • @vaishakhsailor3956
    @vaishakhsailor3956 Рік тому

    Is that the way.. ??I saw different method by connecting bulb in series connection and put the battery on load and note down the ampere and voltage every hour for 10 hours minimum

  • @gbacon4551
    @gbacon4551 Рік тому +1

    I've noticed you did not shut off the charger of gmdss battery while performing the performance test, meaning it continuously charging, maybe you need to switch if off in order to maximize the full power within 24 hours for how how the battery can power independently.

    • @leckylouie
      @leckylouie  Рік тому

      Thank you for your comment sir. When I switched off the supply breaker, that is the power source of the battery charger. It has also alarm that the battery is in use. During power failure, it will automatically change over to back up battery and the LED "in use" will activate . 😁

    • @leckylouie
      @leckylouie  Рік тому

      If the battery charger is in service, the voltage reading is about 27volts because the charger output is 27VDC.

  • @marvinho-9392
    @marvinho-9392 Рік тому +1

    nice lek

  • @axxtv9282
    @axxtv9282 Рік тому

    Moniminitor din pla yan sir ngaun ko lang din alam

    • @leckylouie
      @leckylouie  Рік тому

      Yes po sir. Basta part of safety at emergency power ay kailangan ng routine inspection.