How To Change Pressure Adjustment on A10V Piston Pump - Part 1

Поділитися
Вставка
  • Опубліковано 15 вер 2024
  • In this video, we learn how to change the pressure adjustment on an A10V piston pump.
    Watch part 2 to see the pump be tested!
    ------------------------------------------------------------------------------------------------------
    Visit our website to speak to a representative live: www.fluidynefp.com
    Stay Connected:
    * Facebook: / fluidynefluidpower
    * LinkedIn: www.linkedin.c...
    *Twitter: / fluidyne_fp
    FluiDyne Fluid Power
    31915 Groesbeck Hwy.
    Fraser, MI 48026
    (586) 296-7200
    Sales@FluiDyneFP.com

КОМЕНТАРІ • 14

  • @waseemij
    @waseemij Рік тому

    hELLO John how can we do pressure adjustment for Rexroth A4VSO40DR.

  • @theforgotten081
    @theforgotten081 3 роки тому

    Any info on adjustment on a Rexroth AA4VS0 pump with a mechanical adjustable DA pressure control?

  • @bardiyawilliam
    @bardiyawilliam 4 роки тому

    Hello Sir, are we need to install relief valve in our system? and for adjustment to 3000 PSI I have to adjust load sens?

    • @FluiDyneFluidPower
      @FluiDyneFluidPower  4 роки тому

      Hi Ali! You would adjust the screw below the load sense, or closest adjustment to the pump.

    • @bardiyawilliam
      @bardiyawilliam 4 роки тому

      @@FluiDyneFluidPower I need to adjust my piston pump to 3045 psi, now it's 2750 psi

    • @FluiDyneFluidPower
      @FluiDyneFluidPower  4 роки тому

      @@bardiyawilliam It's always a good idea to install a relief valve as a safety so you do not over-pressurize your system.
      To increase your comp pressure to 3045 psi turn the pressure screw in 3 quarter of a turn that should raise the pressure to 375 psi.

    • @bardiyawilliam
      @bardiyawilliam 4 роки тому +1

      @@FluiDyneFluidPower Thank you very much, I will try tomorrow and give you the news

    • @FluiDyneFluidPower
      @FluiDyneFluidPower  4 роки тому

      @@bardiyawilliam You're welcome Ali!

  • @Inspectorwill
    @Inspectorwill 4 роки тому +1

    And if the dr is bottomed out and turning the pressure adjustment screw does nothing and pressure stays at 950 what then? New pump.

    • @FluiDyneFluidPower
      @FluiDyneFluidPower  3 роки тому

      Hi Will! Sorry for the late reply. We would need to know what type of control you have but for a DFR type control we think you are referring to the FR / LOAD SENSE being bottomed out so the only option for adjusting the pressure would be the DR main pressure adjusting screw. If that is the case and your only achieving 950 psi then there may be a relief valve or stuck open or not seating properly.