Replacing a hot spring spa heater relay board

Поділитися
Вставка
  • Опубліковано 30 лис 2024
  • Check out our newest heater relay video
    • Hot Spring Heater rela...
    Buy parts here:
    www.hottubspasu...
    A video how to change a hot spring heater relay board.
    www.hottubspasupplies.com
    914-237-5606
    orders@hottubspasupplies.com

КОМЕНТАРІ • 13

  • @noatakme
    @noatakme 10 років тому

    The instructions for this board say to follow the jumper configuration on the back of the panel cover. For my tiger river Sumatran using 110 volts, the jumper is set to jump 1 and 2 together. You will notice on the new relay board the TB1 is labeled 1, H1, 2 etc. Therefore you need a new 3 prong jumper with the middle prong cut out to jump from 1 to 2.

  • @TalentNetworked
    @TalentNetworked Рік тому

    Anyone know why the Jets and Clean function won’t come on after changing the Neat Relay Board? Was working prior to the change. So odd.

  • @CRFreek
    @CRFreek 3 роки тому

    How do I know which circuit board is bad? The black jumper between circuit boards when hooked up is causing the gfci breaker to trip.

  • @Trollingfoolsallday
    @Trollingfoolsallday 11 років тому

    Should have done an ohms test on the heater. 6KW heater should have a resistance rating or 9.5k ohms.

  • @stevejill91
    @stevejill91 11 років тому

    Question, I have a new heater board for my caldera spa and like the one you put it it is diff. Which wire (black or wht (lt yellow) goes to H1 or H2. They were on the original board P3/P4. Also do the rest of the wires match the number slots 1,2,3,4,5
    thanks for ant help you gan give

  • @sundogforlove
    @sundogforlove 11 років тому

    Would this work in America also?

  • @daltexasone
    @daltexasone 7 років тому +2

    Their design for the electrical connections could not be much worse. Working those wire slots is painful.

    • @Tren_Rides
      @Tren_Rides 6 років тому +1

      daltexasone hell yess

    • @mariementz1987
      @mariementz1987 4 роки тому

      I can't figure it out! Those wires will not come out!

  • @Trollingfoolsallday
    @Trollingfoolsallday 11 років тому +1

    Why did you cut the ground wire?! Leaving the female disconnect on it is fine. Or put a loop on it and thread the screw through it. This installation is Mickey Mouse.

  • @gregnettles3677
    @gregnettles3677 6 років тому +1

    wow getto repair service...

  • @kernalsanders6538
    @kernalsanders6538 10 років тому

    interesting....I'll hope for the best...