Bahot aacha laga sir apka video.. Mai v electrical se diploma Kiya hun job v karta hun lekin ye bahot chota factory hai Kuch sikhne ko nhi milta ..apke pas ya apke contact me Kahi jagah khali ho to bataiyega sir
Sir , Aap Breaker ko Manually Close Karne Ke liye UVR , Shunt Trip aur Closing Coils Nikalwake Manually Push Button Se Close to Kardiye . Lekin Fault Hone Par Breaker Automatically trip hoga na ? Yehi Mera doubt hai .
@@ElectricalHome Sir , Please thoda elaborate Kijiye . Aap Kaunse Release ke baare mein Bol rahe hain ? Breaker ka jo Khud ka Protection Release hota hai like SR18G ?
Sir , If UV , Shunt & Closing coils are removed from an EDO Breaker to close it manually , then does spring charging remain motorized after removal of all these coils ?
Sir , Aapne Sare coils nikal diye EDO Breaker mein se usko manually close karne ke liye . Lekin Spring charging motor to chhod diye . Toh Spring charging abhi pehle ki tarah motorized rahega ki nahin , Yahi mera sawaal hai .
Super Hit Video
👍🏻 very nice training dear sir
Bahut badiya
Good
More respect from😘🥰😍 🇸🇦🇸🇦🇸🇦
super sirji
Super 💯👍👍💯👍👍💯👍
Thanks for the information 🙏
Excellent
Bahot aacha laga sir apka video..
Mai v electrical se diploma Kiya hun job v karta hun lekin ye bahot chota factory hai Kuch sikhne ko nhi milta ..apke pas ya apke contact me Kahi jagah khali ho to bataiyega sir
Good information
Good sir I like lectures 🙏
Best.information. sir
Thank you so much ❤❤❤
Thank you so much sir ❣️❣️
Sir Schneider p3u30 11kv incomer me spring charge krte hi on ho jata hai kya problem hai
Sir our breaker is not transfer due to bus line failure because of ats what is thing todo
Nice 👍👍👍👍
Sir. ji aap nut nahin khol rahe hai balke scrowe khol rahe hain
Thanks sir❤
Thanks 🙏
Dear Sir
Agr ACB ke Ups se Neutral return aara hai ur mera ACB close nahi hora hai koi solution dijiye pls 🙏🏻
breaker agar discharge mode me hai to uv,st and cc ko nikale ke baad bhi maualy charge kar sakte hai
Han,
Thanks🙏🙏🙏🙏🙏 sir
Sir , Aap Breaker ko Manually Close Karne Ke liye UVR , Shunt Trip aur Closing Coils Nikalwake Manually Push Button Se Close to Kardiye . Lekin Fault Hone Par Breaker Automatically trip hoga na ? Yehi Mera doubt hai .
Hoga. Release se
@@ElectricalHome Sir , Please thoda elaborate Kijiye . Aap Kaunse Release ke baare mein Bol rahe hain ? Breaker ka jo Khud ka Protection Release hota hai like SR18G ?
@@ElectricalHome Humble request to answer my further query Sir .
Han
Han jo breaker me inbuilt hota hai, se trip hoga.
How to operate manually without service condition .
Sir , If UV , Shunt & Closing coils are removed from an EDO Breaker to close it manually , then does spring charging remain motorized after removal of all these coils ?
Sir , Aapne Sare coils nikal diye EDO Breaker mein se usko manually close karne ke liye . Lekin Spring charging motor to chhod diye . Toh Spring charging abhi pehle ki tarah motorized rahega ki nahin , Yahi mera sawaal hai .
Rahega
Sir ji , breaker open kese kore ? Manually breaker is not opening, dg is running since last 2 weeks.what to do to open the breaker
Sir only uv ko nikal le or baki relay lagi rahe tho work karega ya nhi
ACB ON /OFF hoga .
(1) What is UV, Shunt, Closing Coil in Air Circuit Breaker (2) What is CI.Preventer in Air Circuit Breaker