Practical Part-2 UT Angle probe calibration ll IIW V2 & V1 block, Index point Demonstration

Поділитися
Вставка
  • Опубліковано 15 січ 2025

КОМЕНТАРІ • 51

  • @statussign1485
    @statussign1485 Рік тому

    Bahut badhiya Sir......thank you for this video.

  • @subhaschandrakarak3477
    @subhaschandrakarak3477 2 роки тому +1

    Very nice 👌

  • @ndtworld9659
    @ndtworld9659 2 роки тому

    Very useful and knowledgeble video sir
    And a special thanks to you sir 🙏

  • @vishnum7716
    @vishnum7716 Рік тому

    Sir, Your V1 & V2 block calibration's theory and Practical videos Great awesome. thank you very much Sir.

    • @NDTQuality
      @NDTQuality  Рік тому +1

      Thank you for your appreciation.
      Please share it in your groups

  • @thepoint8046
    @thepoint8046 Рік тому

    Thanks sir i really appreciate 🙏🙏🙏

  • @shailendravishwakarma5453
    @shailendravishwakarma5453 Рік тому +1

    Sir how to find true angle.

    • @NDTQuality
      @NDTQuality  Рік тому +1

      Will make a video on that in future

  • @gadhavimanoj568
    @gadhavimanoj568 Рік тому

    Thanks so much sirr 🙏🙏🙏

  • @pankajchauhan4939
    @pankajchauhan4939 9 місяців тому

    Thank you sir 🙏❤️

  • @xyz4299
    @xyz4299 Рік тому

    Thank you so much sir good explain

  • @rajukb786
    @rajukb786 Рік тому

    Thankx sir

  • @dilshankhan7676
    @dilshankhan7676 Рік тому

    Thankyou sir...is type se calibration krne ke bad job pr checking ke time Db ki value increase krni pdti haikya. Sir... Fr chahe job ki thk 50mm ho ya usse kam ho...

    • @NDTQuality
      @NDTQuality  Рік тому +1

      Yes, generally we used to increase 6 dB after this at the time of scanning

  • @saddamkhan8283
    @saddamkhan8283 2 роки тому

    Sir Jo ap batan ko daba rhe h usko dikha kar kariye please

  • @patelgulammohydinishakbhai635
    @patelgulammohydinishakbhai635 16 днів тому

    Aluminium ma 8mm diameter no round bar nu UT karvaru hoy to thay

  • @rahulgarg7307
    @rahulgarg7307 Місяць тому

    Sir normal prob ka Cristal kis material ka bana hota h

  • @justinj2505
    @justinj2505 2 роки тому

    How can I select range in angle probe weld checking? Is it relate to weld plate thickness

    • @NDTQuality
      @NDTQuality  2 роки тому +1

      Two times the sound path.
      So you will not miss indications in first & second leg

  • @shahzadbabar6800
    @shahzadbabar6800 2 роки тому

    Sir, please share details about your ultrasonic machine.

    • @NDTQuality
      @NDTQuality  2 роки тому

      It is Modsonic made,
      Model - Einstein II TFT

  • @abujvijay3559
    @abujvijay3559 2 роки тому

    Good morning sir
    Please send V1 block calibration practical video

    • @NDTQuality
      @NDTQuality  2 роки тому

      Yes, I will share in future

  • @nikhilmisra1631
    @nikhilmisra1631 2 роки тому

    Sir
    API 5L ka vidio bnaye

    • @NDTQuality
      @NDTQuality  2 роки тому

      Still I have not passed any API, so I am not qualified for this.
      I make video only for that topics in which I am qualified/certified.
      But let's see in future, I will think about it

  • @erarunkumar99
    @erarunkumar99 4 дні тому

    Sensitive kese dekhe sir

    • @NDTQuality
      @NDTQuality  3 дні тому

      You can use 1.59 mm hole in V1 block for sensitivity checking

    • @erarunkumar99
      @erarunkumar99 3 дні тому

      @@NDTQuality thanks sir

  • @mozafeer5937
    @mozafeer5937 2 роки тому +1

    sir kisi job per rakh kar angler porob kegiye

    • @NDTQuality
      @NDTQuality  2 роки тому

      Yes,
      I will do it in future

  • @ujjvalsingh5344
    @ujjvalsingh5344 2 роки тому

    Sir x-rays se kitane mm se kitane mm tak ka job kar sakate hai aur Gamma rays se kitane mm se kitane mm tak ka job kar sakate hai

    • @NDTQuality
      @NDTQuality  2 роки тому

      In x-ray, it depends on Amperage,
      And in Gamma rays it depends on source.
      So no one can say exact figure

  • @ujjvalsingh5344
    @ujjvalsingh5344 2 роки тому

    & sir hum Cassette kyu use karate hai film me

    • @NDTQuality
      @NDTQuality  2 роки тому

      Because we don't want to expose the film with light

  • @justinj2505
    @justinj2505 2 роки тому

    Sir I can't move gate to the echo at 100% range. My range is 100. Gate moves upto 99.4.
    Sir can you give a guidence, why this happened?

    • @NDTQuality
      @NDTQuality  2 роки тому +1

      Don't know.
      Have to check machine

  • @harishreddy4844
    @harishreddy4844 2 роки тому

    Dac curve ka video karo sir plzz

    • @NDTQuality
      @NDTQuality  2 роки тому

      I will do it in next few practical sessions

  • @tendupadala5090
    @tendupadala5090 2 роки тому

    sir do videos in english

  • @gyanumishra7981
    @gyanumishra7981 2 роки тому

    SIR THE VELOCITY OF SHARE WAVE IN STEEL IS 3230 YOU SAID 3250 THAT IS WRONG

  • @Rawat957
    @Rawat957 10 місяців тому

    sir 50 SP m SD formula se match nhi ho rha h
    formula Sd= sound path × sin&
    50×0.93=46.5 hona chahiye tha
    but apka crt m 35.9 Sd aa rha h

  • @shubhamvaishnav6178
    @shubhamvaishnav6178 2 роки тому

    Sir aapka contect no. Milega kya....pls...

    • @NDTQuality
      @NDTQuality  2 роки тому

      Please contact me on WhatsApp: bit.ly/2WpT9HD

  • @Towards-Self-Reliant-India
    @Towards-Self-Reliant-India 7 місяців тому

    Thank you Sir.