Dear sir you can't take a same rating capacitors for apfc panel you have to take a different rating capacitors. Bz for apfc panel it needs a steps... Like for 100 kvar steps are 25k, 20k, 15k, 12.5k, 10k, 7.5k, 5k, 5k
Sir you have connected one selector at 1&2 no. Point and connect it to one contactor, i need to know do we need to connect all contactor with separate selector switch
Hello sir... APFC PANEL working with LT Panels or MCC PANELS???? TR... LT PANEL... MCC PANEL.... APFC PANEL FEEDER IN MCC PANEL.... Showing .... After APFC PANEL... Supply where is going????
bilkul laga sakte hai pahle rating conform karo fir jitna rating aaye KVAR ka usaka 80% hi lagate hai vaise bhi capacitor delta mai lagte hai capacitor bank mai
In my apfc panel capacitor ON indication leds are signaling but physically contractors are not ON. Is my apfc is functional mode or not ? how can i fix the problem ?
Jaise agar 50kvar ka jarurat hai to ek 5kvar aur ek10kvar aur do 15 kvar ka kiu lagate ha ....sirf ek hi 50kvar ka kiu nahi lagate ha plz mere is confusion ko dur kijiye plz
Esa hota hai dost hamari indruty mai Kai sari motor hoti hai Jaise hamari ak motor run kar rah rahi hai jisake liye sirf 8/10 Kvar ke pf ki jaroorat hai yadi hm seedha 50 Kvar ka laga denge to dikkat aa jayegi because hamari sari motor ak sath run nahi karati
Dear sir you can't take a same rating capacitors for apfc panel you have to take a different rating capacitors. Bz for apfc panel it needs a steps... Like for 100 kvar steps are 25k, 20k, 15k, 12.5k, 10k, 7.5k, 5k, 5k
Thanks for guidance 🙏🙏
,
Sir bahut hi sundar samjhaye ho
Sir bta diziyega..Plesse
Sir..Apfc relay neptune kea..Conecton..Selctor..Aur green aur red....Push botton sey kaise honge
Sir
Relay digram me no 7+ s1 (5a) no8+ s1 (1a) & no 9 - s2 hai agar 3 phase me ct lagega toh connection kaise kanha lagana padega
Sir you have connected one selector at 1&2 no. Point and connect it to one contactor, i need to know do we need to connect all contactor with separate selector switch
kya capacitor bank use hoo skata he choke wale generator ke sath
Only your video cleared my concept. My basic question you solved that how the panel is connected to LT panel
Thank brother
Apfc panel men connection
Jo wire contractor k A1 mai or baki mai. Supply or push button wo wire joi t hoke usme jaige
L&T ka 4stage apfc ka wiring diagram de sakte hy kiya
Good
275kvar apfc ke lite konsa size ka power cable chahiye
Hello sir... APFC PANEL working with LT Panels or MCC PANELS????
TR... LT PANEL... MCC PANEL.... APFC PANEL FEEDER IN MCC PANEL.... Showing .... After APFC PANEL... Supply where is going????
Bahoot sundar explain sir
Sir ek bar thoda badiya se explain karde ge control wring with suitable digram
Ji bahut jald banaunga ak new series
Sir apfc panel ki relay satting bhi dikhaye
Sir holding waring btaye sme
Good video 👍👌👌 bhot bhot dhanwad sir aap ka
Sir aap pdf meter and DG. KI WARRING KE BARE ME BATAIYE
Mene " selec apfc 346 " relay use ki he
ON krne prr fault aa rha he
' capacitor bank is not connected '
Iska kya meaning he ?
Please
Reply
Sir ACB ko timer se on ,off kese Karen plz BTA den
Watching from Nigeria.... Best video.. Please can i design of panel without using pf auto relay.
Super 👌
Sir auto me Nahi chal rahi hai
Ct kaha per lage hai sir ji
Manual me on karne k liye contactor ko hold nahi kiya
Sir power factor circuite on krne pr indecation konse colour ki honi hy.green ya yellow
Green on
Red off
Yellow Trip ke liye use karte hai motor ke starter mai
Sir my company power is 250 hp so how many require apfcr panel
Sir ucrr falt kya hai
Nice video
Great ho yar ap
Sir nice video, please tell me how to decide rating of capacitor in APFC for HT connected load.
Sir rpm 8 ka programs samjha do
Nice 👍👍👍
Sir, isme apun incoming bus bar se mccb me lete, but output wapis bus baar per kis ke through jaata h
Output nahi jata dost capacitor Bank ko parallel mein connect karke chhod Diya jata
Diagram mein selector switch toh nhi hai aap kyu use kar rahe hai
Vai thoda aur drawing description rahe to aur v acha hota
Baipasse karne ke liye holding जरूरी है ना
ji jaruri hai
@@Tech_Gaurav capacator bank kis liye jaruri hai
@@hvacinformation8580 what'sapp massage karo samjhata hu
@@Tech_Gaurav number nahi hai
@@hvacinformation8580 9720508896
Pdf available
drive.google.com/file/d/1IyiIOElLj6B6_hDWtMrYSCtzfFgmeO5F/view?usp=drivesdk
Sir ji why don't you put holding in manual how will it be without holding
सर जी आपने मैन्युअल में होल्डिंग क्यों नहीं लगाये बिना होल्डिंग के कैसे होल्ड रहेगा
2 lk dear💕💕💕 bhahut hi acha video h dear💕💕💕💕
Thanks sister for support me..🙏🙏🙏
Sir isko drawing se samjhao pls
Without Mcpcb how you can connect Direct contactor
Sir ji alarm kaise hataye
Sir power factor relay mein lag aur lead ka Matlab hota hai
MCC motorized on trip of indication ats lamp taste with emergency
Moter ke Delta me direct kvar laga sakte hai
bilkul laga sakte hai pahle rating conform karo fir jitna rating aaye KVAR ka usaka 80% hi lagate hai
vaise bhi capacitor delta mai lagte hai capacitor bank mai
60 hp moter per kitna kvar lagega
@@Tech_Gaurav 60hp moter per kitna kvar lagega
@@nandkishorprasad4534 ua-cam.com/video/YAfIf8vlncE/v-deo.html
@@nandkishorprasad4534 80% lagate hai hm to lagbhag 26 kvar ka
But 26 ka available nahi hota to hm 20kvar + 5 kvar ka laga denge
In my apfc panel capacitor ON indication leds are signaling but physically contractors are not ON. Is my apfc is functional mode or not ? how can i fix the problem ?
Pls do video on low electric bills.does power factor controls watts or units.
Sariya bending machine ka panel ka connection ka video upload kijiye
Hi Sir, are you a panel builder ?
Sir मेरा लोड 175 kvr है कितने लोड वाले कैपिक्टर लगगे ओर कन्टेक्टर ओर mcb कितने amp की लगेगी
aap mujhe mere no. par whatsapp karna bhai
load to aapka kv mai hoga n
सर कंट्रोलर ऑटो में वर्किंग नहीं कर रहा है
Sar yah bataiye push-button ka to kar Diye Ho Magar hold kaise hoga
Ak next video banaunga proper
Kyq problem ho skta h
Ats panel DG set ke bare video banao ats ko Maine Ali kaise on off kare
Ok dear Coming soon...🙏🙏
Is circuitmeclearconnection nahi ho raha hai
Sr g kya aapse baat ho sakti h
🙏🙏
Manual me wiring wrong hai holding ke liye aapne NO use nahi Kiya Contactor ka
What is meaning of icon alarm and all capacitor is on.
Sir manual chalu nhi ho rahi hai
realy ki programming btaye
Sir capacatior bank se koi load nahi diya jata hai
नहीं दोस्त कैपिटल बैंक से कोई लोड नहीं दिया जाता है LT के पैरलरल में कनेक्ट रहता है
@@Tech_Gaurav ok sir
Ok sir Mera daut kiliear ho gaya
@@hvacinformation8580 jaldi hi capacitor bank se relative dusari videos aane wali hai
Koi doubt ho to comment kar do
Star delta starter me PLC programming.wairing Kaise kare
Ok dost i will try..
Is wiring se to apfc relay off ho jayga fir pf hame kese show krega
Aap meri wiring se relative or vedio dekh sakate hai jisase aapka doubt CLR ho jaayega
Nice bro
Capacitor how to calculate which motor used 1hp 3phase motor & above motor
ua-cam.com/video/Xk4sfEA8XaQ/v-deo.html
14nomberwire kha gya hy timer se
Taemar pusbtn ato menual cantoing bheji
Iska working thoda samjhaiye
Ji bhai next video bana dunga proper
यह parralel में होता है
Relay setting Hindi main
How to need auto and manual switch in 8 stage apfcr panel
If relay failures need to on capacitor manually
Jaise agar 50kvar ka jarurat hai to ek 5kvar aur ek10kvar aur do 15 kvar ka kiu lagate ha ....sirf ek hi 50kvar ka kiu nahi lagate ha plz mere is confusion ko dur kijiye plz
Esa hota hai dost hamari indruty mai Kai sari motor hoti hai
Jaise hamari ak motor run kar rah rahi hai jisake liye sirf 8/10 Kvar ke pf ki jaroorat hai yadi hm seedha 50 Kvar ka laga denge to dikkat aa jayegi because hamari sari motor ak sath run nahi karati
industry mein Jaise Jaise motor ran karti hai aur jitne power factor ki jarurat Hoti hai mein relay utane hi bade capacitor ko on kar deti hai
Iski program kana batao
Ji bhai jaldi hi koshish karunga ☺️
Sir send me the link I could not understand properly
Pdf file bro
capacitst.kaice.cheek.kiya.jatihai.sir
kisi agli videos mai samjha dunga
o k
Apfc ka pura control aur power connection dedo
ua-cam.com/video/SY84LsuvpcM/v-deo.html
Relay ne red alarm show hor rha h
parameter download kar ke reset kar lo bhai
👌
Please stay connected
Holding nahi diye sir
Please Aap isi se relative dusri video watch kar lo dost
Power factor Play list available hai
PDF send me
Sahi se nhi samjhe
Pahle acche se Sikh Lo tab video banana
Galat controlling sikha rhe ho chootita bna rhe ho janta ka deol bnana to sikh lo pahle
Good
Nice
Thanks