Calculate Vaporisation rate (Boil-up Rate) from a batch reactor

Поділитися
Вставка
  • Опубліковано 20 гру 2024

КОМЕНТАРІ • 22

  • @saikiranampolu9652
    @saikiranampolu9652 2 роки тому +1

    Ajay sir i am very happy that finally you started UA-cam we are waiting eagerly

  • @dhruvkumarmangukiya3628
    @dhruvkumarmangukiya3628 Рік тому +1

    Sir u r doing grate work please add more videos

  • @rahulthakor14
    @rahulthakor14 Рік тому +1

    Can you pls explain ANFD complete design with drying rate calculation

  • @gauravjoshi4832
    @gauravjoshi4832 7 місяців тому

    Hllo Sir if I'm using ceramic band heater for reactor heating for boiling off water what temp will be considered for lmtd calculation

  • @silambarasan.s7521
    @silambarasan.s7521 Рік тому

    Sir if lmtd increase y overall heat transfer coefficient will reduce

  • @venkateshkademane2098
    @venkateshkademane2098 2 роки тому

    do you have any online or paid membership programme for answering our questions?

  • @Niju82
    @Niju82 Рік тому

    Sir, What if we use a band heater instead of steam jacket. What will be the LMTD.

  • @venkateshkademane2098
    @venkateshkademane2098 2 роки тому

    sir,we wish u heathy wealth

  • @SAHILPATIL-se4fb
    @SAHILPATIL-se4fb 2 роки тому

    In 2nd case what if we use hot water what would be the u value and how u relate lmtd in that case?

  • @venkateshkademane2098
    @venkateshkademane2098 2 роки тому

    sir,how if heating is double limpet and heating by thermic fluid?

  • @pappalasunilkumar4805
    @pappalasunilkumar4805 10 місяців тому

    sir,why we are consider mλ only for heat demand .why we are not considered M*Cp*deltT Or (M*Cp*deltT+ mλ)

  • @mabasith3877
    @mabasith3877 Рік тому

    Please add more topics

  • @ramtilakpasupula3352
    @ramtilakpasupula3352 2 роки тому

    Please explain column design. No theoretical plates and dia of column q line

  • @ramtilakpasupula3352
    @ramtilakpasupula3352 2 роки тому

    Nice 👌

  • @dhruvkumarmangukiya3628
    @dhruvkumarmangukiya3628 Рік тому +1

    Ty so much

  • @bhagathk822
    @bhagathk822 2 роки тому

    Required more videos sir

  • @rupaadireddy7708
    @rupaadireddy7708 Рік тому

    How to calculate boilup for distilation col

    • @pharmaengineering
      @pharmaengineering  Рік тому

      Calculate the boil-up from the kettle or reboiler which could give you an idea about the boil-up that enters the column and then estimate the pressure drop across column, that would give you the vapor rate at column exit.

  • @dhruvkumarmangukiya3628
    @dhruvkumarmangukiya3628 Рік тому

    In atmospheric distillation
    If i consider toulene as liquid phase having inside temprature 30℃ then what is my LMTD ?
    OR
    WHAT IS my demand is it m Cp ∆T + mL ?

    • @pharmaengineering
      @pharmaengineering  Рік тому

      Hii Dhruv,
      Toluene boils at 110 C during normal distillation i.e., at 760 mmHg,
      So for estimating LMTD you can take 30C as initial temperature and 110 C as final temperature and the jacket utility temperature remains the same (if it's steam)