  • @williamdyckman9704
    @williamdyckman9704 6 років тому +3

    Steve, your the expert on hydronic systems, like the way you explain the flows through the system and the purge stations.

  • @geoffreybram4360
    @geoffreybram4360 4 роки тому +2

    I have a duplex ... 2 boilers as seen in the video. Replacing the existing boilers from 1979. For 2 Weil McLaincga-3 boilers, expansion tanks, demo, and all necessary components is 13 k a fair price? Or is it not as clear cut as that with pricing out a job? Thanks!

  • @DavidS-dj7sn
    @DavidS-dj7sn 5 років тому +1

    Hi Steve
    Thanks for all your helpful vids.

  • @jeffbanks866
    @jeffbanks866 4 місяці тому

    Man you know your stuff!! Thanks for the good video.

  • @paddykalish3309
    @paddykalish3309 2 роки тому

    How do you stop the hissing sound on a Weil-McLaine boiler? Can you please do a step-step inspection simulation? Thank Yoi

  • @J-Colt
    @J-Colt 6 років тому +2

    Thanks Steve!

  • @andrewbroadway
    @andrewbroadway 6 років тому +2

    Steve I love you videos and the dog, keep it up, your an amazing guy!

  • @wskripka1
    @wskripka1 2 роки тому

    Which is a better 80+ gas boiler , a Dunkirk of Weil Mclien ?

  • @harleydavidson3318
    @harleydavidson3318 3 роки тому

    If the combustion test fails, what do you do. I have a boiler like that and when burners shut off it has a funny smell coming from it.

    • @stevenlavimoniere
      @stevenlavimoniere  3 роки тому

      sometimes you can make adjustments to gas valve and air dampers to correct combustion if not you must replace boiler / furnace .

  • @Blobjonblob
    @Blobjonblob 6 років тому

    The amount of things Iv learned off Steve is crazy, Next level mama.

  • @willardearl76
    @willardearl76 5 років тому

    Great video, thanks Steve

  • @mjbplumbing710
    @mjbplumbing710 6 років тому

    So when purging a boiler , how do you know which hose to connect to? Or is it the lowest hose.

  • @Fireship1
    @Fireship1 6 років тому +2

    Nice Job Steve. Lots of heating calls headed your way I’m sure. It cooled off here in NJ. MA must be cooler as well.

    • @volvo09
      @volvo09 6 років тому

      53ish this morning in westboro MA! 22nd day of sweatshirt...

  • @Jilocasindragon
    @Jilocasindragon 6 років тому

    Hey there steve. Would you mind explaining what's the purpose of the high vents? I can't seem to find anything on that term on google (your videos are actually the only ones mentioning that). Does it do something different than the pressure relief valve?

    • @volvo09
      @volvo09 6 років тому

      They are used in hydronic heating to vent air from the heating loops. That might help you find it... Air bubbles up into it and when enough builds up a float releases it. Different purpose from the pressure release, these only vent air unless they get stuck, then they leak or don't vent air and you hear bubbles in your heat.

    • @Jilocasindragon
      @Jilocasindragon 6 років тому

      Ahh, gotcha. Thanks!

  • @mjbplumbing710
    @mjbplumbing710 6 років тому

    Is there set levels when doing a combustion test. To see weather its good combustion or not.

  • @theoldbigmoose
    @theoldbigmoose 5 років тому

    I thought that pretty neat that the zone valves were on the return and downstream of the purge station valves. this seems to eliminate leak points, and frozen isolation valves. What are the downsides?

  • @an_ancient_gamer
    @an_ancient_gamer 5 років тому

    Good amount of knowledge. A little scary to see a pipe wrench on the tp valve brass casting though!

  • @Luvmygrands10
    @Luvmygrands10 4 роки тому +1

    Where exactly are you located? It would be great to find a professional you can trust.

  • @kidalwys
    @kidalwys 6 років тому

    I had one today where I had no purge stations all I had was the high vent and some more copper high vent it was a very weird boiler. Like you say Steve the good the bad and the ugly.

  • @donnierobertson3088
    @donnierobertson3088 3 роки тому

    Nice job and video like always ( Steven )

  • @RayRay-nb7tn
    @RayRay-nb7tn 6 років тому

    Is there a copy of that chart you have for a guideline on the co2 test on you site?

  • @dennisnoone7427
    @dennisnoone7427 6 років тому

    Steve, how often do you have your Testo analyzer checked, is 50ppm for Co is a maximum allowable ?
    thanks

  • @kevinkevin9448
    @kevinkevin9448 5 років тому

    What combustible gas meter is that ???

  • @BoB4jjjjs
    @BoB4jjjjs 3 роки тому +1

    Bomb proof boilers!

  • @bg147
    @bg147 6 років тому

    She has the heat on in September. I don't start mine until the interior temp is pushing 50.

  • @bernardocisneros4402
    @bernardocisneros4402 3 роки тому

    Hi, Steve! Thanks for the video. A lot of good info. I have a question: in the video, you say it's not as important to completely bleed the second floor because they're cast iron radiators. Why is that? Is it because cast iron is heavier or because it's stronger? Thanks again!

    • @garretlizotte6288
      @garretlizotte6288 2 роки тому

      Cast iron radiators have built in bleeder valves.
      Any remaining air in the system will purge itself out using those valves.
      Baseboard heaters do not typically have bleeder valves so it is very important to make sure there is no air left in the system utilizing the hy-vent.

    • @bernardocisneros4402
      @bernardocisneros4402 2 роки тому

      @@garretlizotte6288 Thank you!

  • @cardo1111
    @cardo1111 6 років тому

    Great vids thanks for posting them. I am trying to size a replacement boiler for my house in the lower Hudson valley in NY. It’s a bi level with 2518 heated square feet I have a 115’ of heated fin tube and a Beacon Morris kick panel blower heater that supposedly puts out 12500 BTU on high, based on this my demand is about 80500 BTU. I imagine I would base my sizing on the DOE output number posted by the manufacturer factoring in efficiency of the unit. Slant Fin seems to have a good rep as a brand. My current done Utica is 150000 BTU input. Sounds too big, house was built in 1963, vinyl sided double insulated windows now, what size boiler do you think I should buy? Any suggestions/advice would be much appreciated. All the best

  • @Eddy63
    @Eddy63 6 років тому

    Good vid Steve ... Thought Molly was gonna over sleep ... She's a sweetie ...

  • @Rezcat-y6r
    @Rezcat-y6r 6 років тому

    Great video again. God bless.

  • @richardcdldriver
    @richardcdldriver 6 років тому

    Steve The Working Man

  • @CB-dx6hy
    @CB-dx6hy 6 років тому

    Hi Steve. Could you look at the 1 and only video I posted of this type of unit doing what I could only call short cycling. I'd love to hear any thoughts you have. Thank you Chris

  • @kevinkevin9448
    @kevinkevin9448 5 років тому

    Nice video again

  • @jeffc.3639
    @jeffc.3639 5 років тому

    Question just bought my Mom a house and it has a Weil McClain has boiler in it. Does it have an Air Filter?

  • @tampabaydan3422
    @tampabaydan3422 6 років тому

    Molly the dogs working again Mama she's working again👍👍👍

  • @rl4889
    @rl4889 2 роки тому

    11:25 important part of purging

  • @RayRay-nb7tn
    @RayRay-nb7tn 6 років тому

    Nice job

  • @bg147
    @bg147 6 років тому

    My old hy-vent leaked and my new one leaks. I have to keep the cap tight or it leaks and I have flushed it to remove any possible dirt. Is it possible my system was piped incorrectly to cause this? Anyone.

    • @briangamache2011
      @briangamache2011 6 років тому

      install another new hy-vent , new does not mean not faulty ,have seen it .

    • @bg147
      @bg147 6 років тому

      @@briangamache2011 I could do that. Originally, I figured it was the system and the way it is piped. I don't know how these vents work. If I pull up hard on the schrader valve, it will not leak water.... but is it still venting air? I don't see what principle is involved that allows them to vent air and not water.

  • @Rezcat-y6r
    @Rezcat-y6r 6 років тому +1

    1959. I was gonna turn 6 and we were stationed in Hawaii. All my aunts and uncles were back in Boston.

  • @cotizostan4079
    @cotizostan4079 4 роки тому

    Buna e cineva care se pricepe la bilare cargo astept raspuns as an leeds

  • @jhhvacplumbing1944
    @jhhvacplumbing1944 6 років тому

    Your da man Steve!

  • @Novisk58
    @Novisk58 6 років тому

    never see any Honeywell motorized valves makes me wonder. I have them on my system had one fail a few years ago. The switch inside went bad and was allowing the boiler to fire. . Good thing was I just swapped the head out for a zone I no longer use. Those boilers do look pretty new nice job y whoever did it. Molly needs more air time top tech deserves some recognition. Does she get the scrap as your helper? I think she'll be able to vote in the upcoming elections.

  • @jeffcoolhd
    @jeffcoolhd 6 років тому +2

    Steve can you give baby Molly some more air time. Peace brother

  • @pasqualepapaleo662
    @pasqualepapaleo662 5 років тому

    You are the best do you like Carlann burners guess

  • @cotizostan4079
    @cotizostan4079 4 роки тому

    Buna ziua e cineva care se pricepe la boilare

  • @orangie8426
    @orangie8426 4 роки тому

    Good golly miss Molly.. you sure look mighty fine!!! (New song for you Steve! eh?)

  • @kdmq
    @kdmq 6 років тому

    Boiler must be triggered on entirely by low limit, the thermostat is strictly connected to zone valves which circulate the water and eventually cool the water in the loop bringing the temp down to low limit. Interesting and simple design. However there is no failsafe if the high limit switch fails (that I know of), not good. It is what it is though.

    • @kdmq
      @kdmq 6 років тому +1

      No I don't work on these units I'm not qualified I just do DIY. Would love to learn what happens. My best guess is the relief would blow from the pressure buildup.

    • @stevenlavimoniere
      @stevenlavimoniere  6 років тому +1

      no low limit on this boiler only high .this is what they call a cold start boiler .low limit is only on a boiler with a tankless to maintain boiler temp for domestic hot water .99 percent of gas boiler do not have a low limit

    • @kdmq
      @kdmq 6 років тому +1

      Thanks for the info Steve. I completely misunderstood your statement at 10:30. I thought you said there was no thermostat signal to the boiler at all but rather you just said the circulator was not powered from the boiler. I am in university for engineering and am fascinated by how these systems work.

  • @willtech8426
    @willtech8426 6 років тому +2

    Hellooooo!

  • @miked7091
    @miked7091 6 років тому

    All it needed was a working mans breakfast mama.

  • @miltonproton3179
    @miltonproton3179 6 років тому

    You didn't check de bypass !! It's still open .

    • @gantmj
      @gantmj 6 років тому

      14:16 is him taking it out of bypass.

  • @amirdieselx64
    @amirdieselx64 6 років тому

    Good one mama

    • @amirdieselx64
      @amirdieselx64 6 років тому

      Soon the winterizing will be coming on the vacation homes.

  • @jason-ge5nr
    @jason-ge5nr 6 років тому

    lil molly woke up

  • @pasqualepapaleo662
    @pasqualepapaleo662 5 років тому

    Gas

  • @Richyy_G201
    @Richyy_G201 Рік тому

    damn he nice like dat