staircase two way switch wiring|कैसे करते हैं सीडी वायरिंग by Electric Guruji
Вставка
- Опубліковано 28 бер 2019
- hello friends aaj ki video Mein Hum कैसे करते हैं सीडी वायरिंग यह देखेंगे staircase wiring से हम एक बल्ब को दो जगह से ऑन ऑफ कर सकते हैं
part of make project
1 two way switch
2 bulb holder
3 bulb
4 wire
Product link amzn.to/2YJEfbx
two way switch amzn.to/2HQ8bgD
bulb order amzn.to/2CQYoCZ
LED bulb amzn.to/2CNACYK
bldc ceiling fan amzn.to/2JV61hL
#staircasewiring
#कैसेकरतेहैंसीडीवायरिंग
Thanks For Watching....#ElectricGuruji - Наука та технологія
neutral is never connected to switch. It is connected to bulb or anything direct through "N"line from socket.
1st terminal wire connected in 1st terminal of 2nd switch and 3rd terminal wire connected to 3rd terminal of 2nd switch middle terminal of one switch is connected to load and middle terminal of 2nd switch is connected with phase neutral is Direct
Este tipo de ligação é perigoso,se um interruptor der uma falha, curto circuito na hora
This circute should be dengerous because against the low . Negative charge and positive charge in the switches. Why who is electrician. Good luck
Wire bachane ke liye sahi hai pr danger bhi hai
In correct wiring double phase can occur
Wrong connection the neutral wire should b directly to the bulb and phase should be in the middle..
Wrong connection the neutral wire should b directly to the bulb
Yes .this is the safe method
@@tadepallisrinivas7467 No, the shown method is NOT the safe method.
Two-way switch mein sirf phes use hota hai , neutral detract cancet hota hai
R8
Show the two neutral shoting and phase wire shoting.
Agar dono off honge to dono me phase aayega tab bulb fat Jayega
Sahi baat hai Bhai
Brother don't misguide people. Neutral wire never comes in switch points, don't do this method. Neutral wire should go directly to load or lamp, and one phase to common point to one of the switch, and from common point of other switch to load or lamp. Two switchs connect A1 to A1 and A2 to A2. This method is safe. Above Guruji method is wrong and dangerous. Don't follow this method.
And why bro.. Isme kharabi kya hai
Or bhai thodi salah chahiye
👍
@@mohitbhatia6288 there is an international rule is there. Neutral should not come in switch box other than socket. You cont connect neutral and phase in one switch. Any time switch may get shorted. U cont belive switches if load is more then it will short.
@@mohitbhatia6288 Dangerous
Rxcelente explicacion
Eu gosto e de video assim que ensina direitinho pra nos e a filmagem do video e melhor ainda meus parabens a voce meu amigo abraços
No se entiende a donde van los cables sueltos
Can we use 2 different meter wires to two switches and show the result
Thanku sir bhot achi video banyi hai ap ne👌👍
Very dangerous, connect swich to switch then take the live to bulb holder and the neutral direct to bulb holder, that way live to bulb holder will be turned off from either switch.
Not very dangerous 1000 jgh asei connect krchuka abtk khi se b shikayat ni aai
Its not correct.. neutral should be go directly to the light ..2nd always live wire only use in switch
Mereko barabar pata.nai thaa. Aajh pata chalgaya 2way swuijh kaisey samal karna hey. thanks
In Electrical, safety first. There avoid any further chances for short circuit and shock hazard.
Warm regards sir.
Good
गौरव जी आप का बताया हुआ जो कनेक्शन है यह बिल्कुल गलत है ठीक है आपको 2a का कनेक्शन सीखना पड़ेगा और साथ में इंटरमीडिएट का भी
q@@jaysreeramjaysreeram1678qqqqq
Wooooooo
Bro
Super
Bahut hi aasani se aapne samjhaya dhanywad
Sir apne nutal or faje alg alg board se diye ek hi botton me se bi ho sekte the
माशा अल्लाह ❤😂😂 मुझे बहुत अच्छी लगी गुरुजी आपकी वीडियो
It's not theoretical. It's very dangerous
Ez suszter váltó!!! Azért hívják így, mert villanyszerelő nem csinálja. Ez baleset esélyes.
Tem que mostrar a conexão dos cabos.
Já reparou que nunca muda o lugar de acender . Porque não funciona. Eu acho que tô desaprendendo tudo que aprendi.kkkkkkkkkkkk
Very knowledgeable thank you
In this video
U show there
2 different side phase ...
So can we do it by one side and if yes then how
? Answer me asap....
2way switch se tv chala sakte he ky
Nice... Jay Jagannath...
Two ball connection two way switch per wiring
Sir ji aap se hath joda kar nivedan hai ki gsm mobile stater kit ki wiring dol starter se kaise hoti hai iske liye ek video bana do please
Sar bahut hi badhiya lga aise vidio banane ke liye bahut - bahut dhanyabad 👌👍
👌🏽 👌🏽 👌🏽 👌🏽 👌🏽
क्या दो अलग-अलग सप्लाई से एक बल्ब जला सकते हैं जैसे दोनों घरों में सिंगल सिंगल फेस की सप्लाई है तो
Nice video Bhai 💯
Thanks everyone easy to know
Dono switch off karenge to bulb ki Dono wire mey current rahenge.
Sirji agar dono switch on ker diye to koi sort crkit to nhi hoga
sir ji dono wire mein phase or Newtral dena hoga..?
tin lamp ak fhen ak sivech se band hu asee vireeng bataeye
Very nice work
wah guruji
This circut is very good I am interested Congratulations to you thanks Assalam u Alaikum goodbye
Bahut achhe
नासा सर सर यह जो आप बता रहे हैं तो उसको एक ही एमसीबी में से होना क्या अलग-अलग एमसीबी में सभी चलते हैं यानी कि ऊपर की जो एमसीबी है वह अलग रहती है और नीचे की जो एमसीबी हुआ लग रही थी तो एक ही एमसीबी में यह दोनों एमसीबी
Tq sir
Main Soch Raha Hun Bhai koi aisa video banao joki ki Ghar Ke Andar Jaate hi light on ho jaaye
Good 👍
Connect only phase wire...
Neutral never comes in switch box. May be it works for lights for some time, for fan it won't work, with in few days it will short. Mainly short in switch, some times other equipments like TV , other bulbs will burnt out. Be careful, don't do this method circuit wiring.
I am an electrical engineer, trust me I experienced this.
@@arunprasad8182 👍
Wrong connection
Mass gurujiii 👌👌👌👌
Thank u achi video hhhh.
Agr dono phase button on rha to??
Halo giruji3/5 sujeka
Two-way Karen.
Par jab switch off hoga, tab dono wire me phase ya to neutral ayega… 😒
Yes
kuch nahi hota hai phase ko phase milega nahi to neutral ko neutral milega samaj gye kya
Positive positive mil gya to😏
👍
Very Good
Thank you very much
दतभय्
Dono ek sath on kardiye to?
Guruji you are wrong, the connection is wrong, don't play with electricity it never excuses, it causes danger for your audience.
Immediately remove this video asap.
S bro
Explain the best method if you are expert@sai kumar
@@shafiteli2812 Bulb should be given separate neutral but in video the wiring is done using Both phase wires and also the circuit diagram is wrong.
The basic is that a bulb should have both phase and neutral to glow. But in video only the phase is taken for both ends and there is no neutral.
खतरनाक है
Thank you sir
भाई थारी जानकारी के लिए यो बता दू के या बल्ब को बल्ब बोला जाता है ना कि बल्फ। दूसरी बात यो बता के या स्विच के टर्मिनल अगर जल जावे तो घर में भड़ाम bhadoom का जिम्मेदार कौन होगा
Cómo conectar 3 apagadores de escalera en corto sircuito
Switch jalne ka khatra he bhai onli fech wairing sachi he
Tq sir 🙏🙏🙏
Mantap saudaraku
Sahi bat
Ye wiring koi se bhi company ki switch m kar sakhte h kya
Very nice
I mean ek sath dono switch use na krte huye ek ek ko bari bari use kre jaise ki ek se on kiya. To usse se off kre or ager dusre ko use kre to useii ko use kre to kam kre ga kya???
Nhi, bulb fuse ho jayega, Dono tarf se phase jayega, Main bhi yhi dekh rha hun, cross connection best option hota hai,
thank you
Wrong ****swich me kabi neutal Dena nahi
Right
👏🏿👏🏿👏🏿
Dono line me ak sath fase Diyatha
Kya is connection me ek hi switch se band chalu kar sakte hai
2way switch se tv cular control karsakte he kya
En las puntas a que parte van ya que en el video hay dos puntas en cada conmutador
Rong connection bhai bulb me direct neutral dena honga aur buttons me only phass honga... neutral nhi..
ತಪ್ಪಾದ ಪದ್ದತಿಯ ಜೋಡನೆ
Its working properly but connection is not correct
May be some times it will work only for lights not for fan or heavy load
Dono switch off rehega to shots hoga na
Ni hoga
Pramod sharma
Bihar ara
led build ja lega ?
Je dangerous hai dusra tarika v hai jismai ek switch se phase in or out karba ke dusre switch mai dete hai neutal direct dekar karenge safe rahe ga
A donde van los cables en ambos extremos no explica ni se ve por el idioma no se entiende
Very good
Extremely dangerous and forbidden in most of the countries world-wide (in the US for example since 1923)
How it is dangerous ?
@@leolearning3048 If you don't know that, then you shouldn't be allowed to do any electrician work anywhere. It's dangerous, because even if a (working) bulb indicates "power off", both lines to the bulb can carry electricity, and you can electrocute yourself when touching the socket or other parts of the lamp.
As said, this wiring is forbidden in almost any country in the world, and on top, maybe it's even forbidden in India ... Not sure yet, as I haven't seen a copy of the Indian electrical code yet ..
And: Of course, there is a correct way to wire the switches, but that is not shown here.
@@manofnorse thank you so much for your time for explanation. I appreciate your time . I'm from India. In my house same kind of wiring is done. One of switch failed so I replaced and saw little spark on it. So I asked this .
Gud
nice mara mind ghoom gaya kamaal ha..
Não fase está instalação aqui no Brasil
1- Neutral direct connect krdo
2- take 2 two way switch
3- Dono buttons ka mid point yani common point hoga ak button k mid mei phase lgado dosray button k mid mei lamp ka phase lgado
4- 1st switch ka upper point 2nd switch k lower point say connect kro
5- 1st switch ka lower point 2nd switch k upper point say connect kro
Abe jis din switch karab hoga na us din tumara vdo follow karnewalon ka ram nam satya hoga 😀
اس کو ہم نےعلیدہ کرنافرض کرے ھم نے دو بلب لگاے ایک نیچے ایک اوپر اب ھم نے ان کو الگ الگ کرنا ھے کیسے
Prohibited by the law ..very dangerous wirring
Is connection me kya hum led bulb use kr skte hai?
Brother it's a wrong connection.
Bhai do switch laga kar ek hi switch se on off nhi hoga kya
bahut Shukriya
Maa bhi board banata hoon but aaj. kuch different seekhana ko mila
Isme balb me jo wire gya hai vo p-n,n-p bar-2 hoga
I was shocked when I saw the thumbnail bhai q galat bta rha hai😂