Where Should We Be Using Dual Function Breakers?

Поділитися
Вставка
  • Опубліковано 15 жов 2024
  • When installing circuitry into a residence, it is important to refer to the NEC to determine exactly what types of protection are needed. GFCI protection and AFCI protection being among them. But what about dual function breakers? In the latest episode of Electrician U, Dustin brings to light what a dual function breaker is and where would be the places to install them.
    🤘⚡️EU Learning System⚡️🤘
    For Individuals --- electricianu.c...
    For Businesses --- electricianu.c...
    -Video courses on every side of the electrical trade (theory, code, safety, wiring, install, troubleshooting, leadership, and more)
    -Practice exams for 2017, 2020, 2023 code
    -UA-cam videos categorized and searchable
    -Audio lessons
    -Forum
    -Business version has admin portal and ability to assign learning to technicians and monitor progress
    -Any business size from 2 techs to 2,000!
    🎓💡CONTINUING EDUCATION💡🎓
    Sign up here --- electricianu.c...
    -State Approved
    -Video Based
    ✍📝PRACTICE EXAMS📝✍
    Get them here --- www.electricia...
    -2017, 2020, and 2023 NEC versions
    -Online Residential Wireman Exam
    -Online Journeyman Exam
    -Online Master Exam
    -300 Question Online Code Cannon (not license specific, all code)
    -Take as many times as you want
    -All of the above come with printable PDFs
    🎤🎧PODCAST🎧🎤
    Spotify:
    open.spotify.c...
    Apple Podcast:
    podcasts.apple...
    📱👍SOCIALS👍📱
    TikTok - / electricianu
    Instagram - / electrician_u
    Facebook - / theelectricianu
    Reddit - / electricianu
    Rumble - rumble.com/c/E...
    Discord - / discord
    🎧🎹Music, Editing, and Videography by Drake Descant and Rob LeBlanc🎹🎧
    #electrician #electrical #electricity
    Let’s discuss the difference between the standard GFCI breaker, a standard AFCI breaker, Combination breakers, and Dual Function breakers so there isn’t confusion with terminology. A standard GFCI breaker senses the difference between what’s going OUT to the load and what’s coming BACK and interrupts the circuit if there is a big enough difference to cause damage to personnel. There are 2 kinds of standard AFCI breakers. A Series AFCI breaker will sense if there is a break in a single wire (where there would be an arc from one side of that wire to the next) and will interrupt the circuit. A parallel AFCI breaker senses a small amount of arcing between a neutral and a hot of the same circuit (not enough to be a dead short but smaller arcing) and interrupts the circuit. A combination breaker has the capability to protect from BOTH Series AND Parallel arcs. And lastly, a Dual Function breaker will protect against Ground Faults AND Arc Faults.
    The installation of a GFCI breaker isn’t specifically lined out in the NEC, just that GFCI protection for certain devices is required. Remember, GFCI protection is generally limited to the device, whereas AFCI protection is required for the entire circuit. Considering both the need to keep cost down AND convenience for the end user, a single GFCI breaker could take the place of several GFCI receptacles within a circuit or negate the need to run a large distance to protect the next receptacle in line of the GFCI device protecting it. In other words, a GFCI breaker will protect ALL the receptacles on the circuit. An AFCI breaker will do exactly the same thing, just from an Arc Fault standpoint in lieu of a Ground Fault.
    Article 210.8(A) of the NEC covers GFCI requirements in a residential installation while article 210.12(B) covers AFCI requirements of the NEC. If you were to look in the code, you would see that several of those areas are required to have BOTH GFCI and AFCI protection. Enter the Dual Function Breaker. Take a residential kitchen for example. You could put a dual function breaker in several of the circuits in the kitchen, thus negating the need for an AFCI breaker AND a GFCI device.
    Another reason to use a dual function breaker in lieu of both a breaker for AFCI protection and a GFCI device for protection is that the breakers tend to be a bit more robust and will fail less frequently than a device. Especially the WR GFCI breakers installed outside as they are constantly exposed to the elements. This, overtime, could amount to significant savings in replacement. As always, refer to the current version of the NEC to find the protection requirements for your situation as codes are reworked every 3 years. Also, it may be work answering customers questions as to why you would install a Dual Function breaker or individual devices. It certainly pays to help them understand why we install things the way we do.

КОМЕНТАРІ • 280

  • @josheh4
    @josheh4 Рік тому +17

    These videos have been coming out just in time! Was looking to have an electrical panel replaced, and a few of your recent videos have helped answer a number of questions I had. I'm going to leave it up to an electrician to do the physical replacing, but now I have a better understanding of what I'm looking for in a replacement panel.

  • @JosephMilici
    @JosephMilici 5 місяців тому +6

    Was updating receptacles to TR in my family room and the breaker tripped out on AFCI as soon as I turned it back on. I went back and checked my wiring to find that when I had pulled the tab on the receptacle to enable half to be switch-controlled, it left a small burr that was arcing. The AFCI may have saved my bacon.

  • @morlamweb
    @morlamweb Рік тому +3

    In my area, for Siemens breakers specifically (as I have a Siemens panel), the CAFCI / GFCI / dual-function breakers are the same price, $50 per breaker. I decided to go with dual-function breakers for most of the circuits because there's little benefit to going with CAFCI-only breakers. When I moved in to my house, there was only one GFCI breaker in the box, for the bathrooms, not even the kitchen or basement outlets. I've upgraded most of the breakers to dual-function slowly over time due to the cost.

  • @thebnbaldwin
    @thebnbaldwin Місяць тому

    Thank you! Once again a great video. I am a handyman with decades of electrical experience in the Telecom industry. My customer's house was built in 2019 with EATON service panels (main and a sub panel for Casita and pool equips., etc.), and has 13 defective of 21 DF breakers (won't reset, tripping when no one is there for months at a time, they are AZ snowbirds from IA) or, the test button buzzes but won't trip the breaker. 4 of 9 GF breakers are defective. I made a chart to see what I can move around, replace a DF with a AF or GF, or even a standard breaker to save him some money. This video will help me do it but, in the end, I think it would have been less effort to just replace them all with what's there already. But then I would not have learn as much as I have about these damned things! P.S. Like the really old AFCIs, I think theses DFs are going through revisions to mitigate failures of this magnitude. Fingers crossed.

  • @Paul-jp8zz
    @Paul-jp8zz Рік тому +14

    I just did a big complete kitchen remodel and due to upcoming code changes and frankly, supply chain, I used dual function on every circuit - all appliances (except the 240v 50amp oven) lights and SABC's... Inspector said "yup, that's pretty much how ya gotta do it these days"... $$$$$$

    • @Squat5000
      @Squat5000 Рік тому +10

      Yep. Amazing what happens when the people that make billions selling a $5 breaker for $50 get to write the mandate.
      I need to invent something I can force everyone in the country to install by code LMAO

    • @mygoogleemail2063
      @mygoogleemail2063 8 місяців тому +3

      Guy who taught me told me something that still rings true after 20yrs.
      "Its a product-driven code"

  • @G.I.JeffsWorkbench
    @G.I.JeffsWorkbench 6 місяців тому +1

    Great video (as usual). Please stop at GFCI protection if you have a metal or wood working shop AND have tools with BRUSH motors. AFCI protection will cause nuisance tripping in this instance. I regularly use a 70-year-old Radial Arm Saw (RAS) in my production woodworking shop that is technically part of my dwelling (converted garage). The RAS, and all of my older routers (for example) still have motors with brushes. Most (all?) new tools are “brushless,” so this will allow AFCI protection. It’s cost-prohibitive to replace all tools with brush-containing motors with new brushless ones. Thanks NEC for allowing this exception.

  • @camdendexter
    @camdendexter Рік тому +13

    Is there a reason to *not* do combo AFCI/GFCI breakers for *every* breaker in your home?

    • @Hatim.13
      @Hatim.13 Рік тому +3

      Cost, a panel change used to cost around 300$ between the panel and breakers, now it will cost around 1000$ in gfci/afci/dual breakers, a regular breaker may cost 6$ to 15$, a dual function breaker may cost between 60$ and 80$...

    • @alonsoserrano199
      @alonsoserrano199 Рік тому +1

      But if you don’t mind spending the extra money wouldn’t it be better to do it?

    • @Jerry-rd9my
      @Jerry-rd9my Рік тому +4

      Nuisance tripping is reason enough not to do it. Perfectly good circuits may occasionally (or immediately) trip just because a bare equipment grounding conductor in an outlet box is touching the termination screw for the grounded (white) wire on a receptacle, for example.

    • @pitsticm
      @pitsticm Місяць тому

      When I had my panel redone I put dual-function on everything. There are a few nuisance trips I've had, but more often than not when a trip happens it's indicative of a problem, and doing this exercise has shown me places in the house that were not wired correctly. For instance, my radon fan failed due to a GFCI fault, and had it not been on a GFCI breaker, I would probably have never known the system had failed.
      I also highly recommend going through your entire panel and labeling it very very clearly. I have a spreadsheet that I print out and attach to the inside door with magnets, and whenever I learn more or a change happens, I change the spreadsheet and print out another copy. The exercise of labeling, down to every receptacle and switch, which breaker everything was on (including the attic and outdoor motion lights) helped me find issues, too.

    • @j.j.riverhill2831
      @j.j.riverhill2831 Місяць тому

      Future inspector lmao

  • @BlackfyreApprenticeX
    @BlackfyreApprenticeX Рік тому +1

    Would love to have a video about electrical in the Attic. What kind of box? Where can I mount it? Does romex just get stapled to the wood or do I drill holes through it? Etc...

  • @calvinjosey5784
    @calvinjosey5784 Рік тому +3

    I cannot get enough of your videos, and appreciate them so much. I was curious if you have done a video on overload current protection on secondary conductors? I’ve been telling the apprentices I work with to watch your videos, and one of them just got a 66 on their last quiz pertaining to secondary conductor protection. Much thanks and please keep posting code videos!

  • @jimmyfox231
    @jimmyfox231 9 місяців тому

    This is super detailed and a great educational tool for anyone looking to learn about arc fault/ground fault breakers. Has anyone dealt with Siemens afci/gfci dual breaker tripping? I have them in my kitchen and laundry rooms both of which trip for a blender and heat pump washer/dryer. I’m replacing both with an arc breaker and gfci blank in my crawlspace for the kitchen because they combined two receptacles there that need gfci protection. Anyone with info on those breakers would be great. I’ve tried replacing and they consistently trip no matter what but don’t trip on regular arcs or other gfci’s.

  • @jaymazza69
    @jaymazza69 Рік тому +8

    I believe I saw that the 2023 code was going to require EVERYTHING in a kitchen, basement and the exterior of a dwelling to be GFCI protected. The only exception would be where a manufacturer specifically states GFCI protection not be used due to incompatibility issues. But that will only be a temporary exemption as the manufacturers will need to address that issue.

    • @jdcpe17
      @jdcpe17 Рік тому +4

      exactly. EVERYWHERE... this guy is referencing the 2013 code for some reason... its changed a lot in the past 10 years.

    • @jaymazza69
      @jaymazza69 Рік тому

      Of course it all depends upon which version of the NEC your particular location has adopted. Some are still several versions behind, which can be confusing sometimes, even for the inspectors.

    • @Jerry-rd9my
      @Jerry-rd9my Рік тому +1

      It's true. (A)(6) in 210.8 now just says "kitchens" meaning all 125- through 250- volt receptacles in the kitchen require GFCI. However, there is a list of locations at the end of 210.8 (in 2023 NEC) where receptacles everywhere are exempt, such as ANY type of security system(fire, burglar, high water, carbon, etc.,) that is permanently connected to a receptacle. That applies in any room in 2023 NEC, not just basements anymore. Also, ice melting equipment at gutters/eaves is still exempt. There are two more I think, I would have to look.

  • @Sembazuru
    @Sembazuru Рік тому +11

    Another advantage to putting the protection in the panel vs. as a device down the line (for example a GFCI outlet) is faults on the home run (like someone drilling through or putting a nail through the home run wire) should cause a trip instead of a death.
    A minor disadvantage is if using a GFCI outlet tester, one has to return to where the panel is after checking each outlet instead of returning to the (hopefully nearby) GFCI outlet.

  • @jimmiegill3981
    @jimmiegill3981 Рік тому +6

    I put duel function on everything ! They area a better breaker than the standard afci

    • @harveypaxton1232
      @harveypaxton1232 3 місяці тому

      I would have to disagree on that. As a service electrician, I have to replace more AFCI breakers than ever. It makes me a lot of money, but it's bad for the customer.

    • @bombitvcajita
      @bombitvcajita 3 місяці тому

      5:28 finally goes to the book after lotta talking

  • @sparky178
    @sparky178 Рік тому +6

    Just wired a basement, the wet bar area has a decorative stone wall. Had to put in 2 receptacles to meet code. I used a dual function breaker so I didn’t have a GFCI and duplex receptacle in the decorative wall. Now will have 2 matching duplex, just an aesthetic thing!

  • @chadrowland5234
    @chadrowland5234 Рік тому

    One of my favorite applications for combination AF/GF breakers is retractable hoses for central vacuums. Retractable hoses are wired to power 24/7 and it would not have a cord or plug. So, it will not be plugged into a receptacle. However, the code still requires AF protection for those. And, though it is hardwired, the hose still has a receptacle at the end. For central vacuum accessories that are hardwired, I just use a combination AF/GF breaker and call it a day. However, I go a step further. I put a wall switch for hardwired vacuum cleaner accessories. You shut it off when you are finished so, there is only power in the hose during cleaning.

  • @harveypaxton1232
    @harveypaxton1232 3 місяці тому

    How do you feel about plug in/on neutrals? I always put combination receptacles on the Kitchen SA circuits due to amount of nuisance trips that come from that area. It saves the customer from having to go outside to reset the breaker. (Calif.)

  • @JohnThomas-lq5qp
    @JohnThomas-lq5qp Рік тому

    Had a few older customers who had me remove GFCI breakers in hard for them to access basement panels to reset them. Installed GFCI on first box from panel.

  • @matthewmontgomery1015
    @matthewmontgomery1015 Рік тому +2

    Dustin,
    Thanks for the video! Seems I should be good to replace all circuits with DF breakers once the FPE panel gets replaced. I don't have a welder at this time but appreciate the clarification in having atleast one dedicated circuit for it in the garage.
    Also much easier to monthly test a set of breakers rather than the outlets throughout the home!
    12/2 throughout but the panel seems to have MWBC since the breakers share a space? Didn't think you could do that with 12/2?

    • @Silky_boi
      @Silky_boi Рік тому

      I don’t think Multi branch circuits don’t work with AFCI. You can use a dual pole gfci breaker with multi branch. I did for my washer dryer and my dishwasher and disposal

    • @matthewmontgomery1015
      @matthewmontgomery1015 Рік тому

      @@Silky_boi pardon my ignorance, I'm still learning.
      But the issue I'm foreseeing is that I have 12/2 Homeruns throughout, which I believe to be MWBC given the FPE load center runs 12space NA feeding 8space NC sub. 2spaces NC are open, 1space is a Full, the other 5spaces are minis(2ea). I don't see how they could run the minis without shared neutral on a single space?
      (It's highly probable there are larger gauge cables for the 60A 2P and 50A 2P but I have not seen them yet. Everything I've found in the attic is white romex stamped 12/2.)

  • @stephendinan5622
    @stephendinan5622 Рік тому +3

    I always just use dual function breakers it makes my life easier for wiring panels and for the purchase of breakers

  • @ivoted7199
    @ivoted7199 Місяць тому

    I'm a GC & learned useful techniques here. Thanks a lot. ;)

  • @brotheradam
    @brotheradam Рік тому +1

    I actually ran a 'blank face' gfci for my fridge and another for my freezer, both at height and space so they are visible, and labelled. My dishwasher and washing machine are the same- the gfci is above but behind the machine so it is visible and accessible.

  • @HopeOverComesFear369
    @HopeOverComesFear369 Рік тому +1

    wanted to share with you hoping you read this comment I went to school to become an electrian in chicago il at coyne witch just recently close I was there when the 911 took place graduated but never really got involved with the field afterward because I also tried to get in the union but wasn't able to get a high enough score so I just gave up but also tried to get back involved in the trade because I found my working in warehouses and kept getting the life drain out of me and I couldn't take it anymore because I kept accepting low pay when I know I have much more value but to get to the point ive been trying to reteach myself and its been hard but not to say ive don't remember what I was taught but I've been doing my best to restudying the trade because I would like to do residential work but am not to firmailar what some things I was taught and the course was like a rush course as well but there were some areas I lacked in like conduit venting and wiring a whole house and that s why I wanted to get into the union plus I was younger that I was now but the reason am sharing all this is because you have me teaching new things every time I noticed something you place on the UA-cam channel and am thankful for your teaching on UA-cam and I wanted to express that to you as gratitude and if you could kept up the awesome job your doing because it help me and others thanks God bless you !!!!

  • @mikieboyblue
    @mikieboyblue Рік тому +3

    The challenge I have is that electric ranges and dryers need gfci as well going forward. I have a very hard time finding those breakers and they seem to cost nearly $100.

    • @morlamweb
      @morlamweb Рік тому +3

      Yep, that's what I found for pricing on the 240V DF breakers. fortunately, existing installs in homes are grandfathered in under the old rules. It's only new builds, or extensive renovations of old homes, which will need to meet the new requirements (assuming that the state as adopted the latest NEC for their building codes).

  • @Sssadow
    @Sssadow 11 днів тому

    SO helpful! Thank you!

  • @IntelestateNetwork
    @IntelestateNetwork Рік тому

    Great explanation Dustin, keep up the good work. Love your videos. When are you moving to CO?

  • @darinjohnson3671
    @darinjohnson3671 Місяць тому

    I was confused which one to use. I will run the wiring and get a licensed electrician to hook up the dual breaker for me. I think just use duo function breakers is a good practice

  • @johndomin
    @johndomin 9 місяців тому

    Can you do a video on what locations or receptacles does NOT NEED afci or gfci protection

  • @hansmortensen5668
    @hansmortensen5668 2 місяці тому

    Question for the smart old (or young) Folks in the room. What am I supposed to do with an older home that still has cloth 2 conductor wiring. I added a dual function breaker to my kid's room with the hope that it could save him from a shock. Also, will be adding the new tamper resistant plugs. Is this adequate, or am I just totally off base? Also, can I test it at the outlet somehow? This is in an apartment home, so I can't really redo the wiring but got permission to make these changes at my own expense.

  • @josephharvey2772
    @josephharvey2772 Рік тому

    I am working on a project for my Cabin (off grid solar/generator) and having to run all new electrical for this. The A/C is just a window unit or two and heating is typically just a wood stove. I am curious with the inconsistent environment and down time on the system would you recommend using dual breakers with the minimum of code or would you use dual breakers for the entirety.

  • @calmeilles
    @calmeilles Рік тому +20

    I have not been really convinced by arc fault detection because all the "evidence" has come from the makers of… AFCIs. However they're in code now (or very close to being mandatory in Europe) so we fit them. Basically I'd fit dual function GFCI-AFCI breakers _everywhere_ unless there is a positive reason not to.

    • @Krankie_V
      @Krankie_V Рік тому +8

      They work, at least sometimes. Installed a whole panel full of them at a friend's residence and two of them kept tripping. We found the wires had been chewed on by some animals. We replaced the damaged wiring and a year later there's not been another issue.

    • @nateo200
      @nateo200 Рік тому +1

      Nuasance trips are a risk especially with certain devices like treadmills which for whatever reason can trip them.

    • @CopeBUILT
      @CopeBUILT Рік тому

      @@nateo200 and this is why i HATE arc fault. I know home builders who put them to pass inspection and get the COI... and then they took them all out, and put normal breakers in to avoid the call backs... and took those breakers down to the next build to use them again on the next house...
      GFI are cool... but the Arc Fault constantly nuisance trip.

    • @ronstewart5945
      @ronstewart5945 Рік тому +5

      ⁠@@CopeBUILTsounds like those home builders are risking a manslaughter charge.

    • @curtisbme
      @curtisbme 8 місяців тому

      @@CopeBUILT Having a crappy old device with a motor that is tripping it is the crappy old devices issue, not the breaker.

  • @CA-lk6fd
    @CA-lk6fd Рік тому

    Basically on new residential, we put dual function on everything but the garage plugs, bathroom plugs, and gas furnaces. We still install the standard breakers and GFCI plugs on these because that gives a few circuits that aren’t arc fault mainly for construction. The arc fault part of these DF hate compressors and saws. We are still running off of 2017 code here in Kentucky, supposedly they’re going to adopt both 20’ and 23’ updates sometime in 23’. We started using DF for simplicity, and reliability, DF breakers don’t seem to have the nuisance tripping like AF. We’ve been using Square D, but we’ve had to switch to Siemens lately because of availability of Square D. I hate that because it’s a really good product IMO, and we didn’t have trouble with them. I have anxiety about this new update because I don’t know how HVAC equipment is gonna do on GF. I thought the same with refrigerators but so far only Samsung had the issues, but they must’ve corrected that.

  • @fwgmills
    @fwgmills Рік тому +4

    A great example of arc-fault nuisance tripping is I have a humidifier that cycles on and off, but the bi-metalic strip that cycles the unit has 120v on it and it sparks and trips the breaker, and sometimes it will trip multiple breakers since all my arc-fault breakers are on the same phase. I have to just manually turn the humidifier on and off and keep the "humidity" dial at max so it won't pop the stupid breakers.

    • @chito80246
      @chito80246 Рік тому

      Good call. I was going to do what you described with 5 humidifier. Thank God I did not. I was going to have the same problem.

    • @Squat5000
      @Squat5000 Рік тому +3

      And the best part, the only solution you're going to hear is that you just need to buy new equipment LMAO.
      I can't tell you how many homes I've wired over the years. But I can tell you a lot of them change them back to standard breakers after I leave lol

    • @jfbeam
      @jfbeam Рік тому +2

      @@Squat5000 THAT is the correct answer. (after inspections are over, remove the damned things.)

    • @TwilightxKnight13
      @TwilightxKnight13 Рік тому +2

      Good to know. We upgraded our service and replaced the entire electrical system with dual function protection. We have not installed the two dehumidifiers in the basement yet. One is brand new, the other an older model. Guess I'll run dedicated circuits to them so if there is nuisance tripping, I can just replace the breaker. Thanks for the info

  • @paltomare
    @paltomare 11 місяців тому

    Thanks for these videos....Does a dual-function tandem breaker exist to fit a Seimens panel? I cannot find one.

  • @jasonrwilliams2573
    @jasonrwilliams2573 Рік тому

    Can you do a video on private fishing docks with boat lifts? I'm in Florida. Thanks

  • @L3Dhelpguide
    @L3Dhelpguide Рік тому

    Theres been a drift toward afci main panel for residential service panels. Penny for your thoughts on if turning on a vacumm or installing a bad light bulb should be able to remove power from the entire system.

  • @RJ-ej1nr
    @RJ-ej1nr Рік тому +5

    Dual function is great for meeting both AFCI and GFCI requirements compactly and with lower cost than doing them separately. I don't like adding AFCI (via DF) in retrofits where not required due to nuisance tripping, but new is ok. The lack of requirement for AFCI in commercial environments implicitly shows their challenges in being used everywhere as a safety device.

    • @Sparky-ww5re
      @Sparky-ww5re Рік тому +1

      A common problem in retrofits, specifically older houses, is neutrals from different circuits tied together, and multiwire branch circuits, and I've seen mulitwire circuits on random breakers placed wherever there was space in the panel, so just because you don't see double pole breakers doesn't mean there isn't multiwire circuits in the house, which is a code requirement and a safety issue. A few manufacturers have double pole AFCI breakers in their product line, which can be used in multiwire circuits.

    • @RJ-ej1nr
      @RJ-ej1nr Рік тому +1

      ​@@Sparky-ww5re Good points! I find multiwire fairly common in late 80s and 90s wiring, and frequently the multiwire is not on a shared trip. Going back to dealing with knob/tube, shared neutral/return was the practice. I've used many 2 pole AFCIs and GFCIs, but I am not aware of any dual function 2 pole breakers, at least not for SqD/Siemens/Eaton.

    • @Sparky-ww5re
      @Sparky-ww5re Рік тому +1

      @@RJ-ej1nr through extensive research, two pole dual function breakers do not yet exist although I can see them being widely available in the next decade if not in the next code cycle or two. The 2020 NEC is already requiring the 30 amp dryer receptacle, and the 50 amp range receptacle if within 6 feet of the sink I believe, to be GFCI protected, and AFCI protection requirements have grown extensively over the last couple code cycles, to include all 15 and 20 amp 120 volt circuits within a dwelling unit, for all practical purposes. Even the 240 volt, 15 and 20 amp receptacle like you might use for a large window air conditioner or large electric heater, is now required to be tamper resistant, so I can see where we're heading in the not so distant future.

    • @jfbeam
      @jfbeam Рік тому +2

      Or it shows they aren't as necessary as they claim.

  • @tebogan
    @tebogan Рік тому +3

    As usual, great usable information

  • @jonesgang
    @jonesgang Рік тому

    In older homes this is not as straight forward if the homeowner wants a panel upgrade where lights and outlets are on the same circuit. Now you have to weigh the cost difference between AFCI with GFCI outlets or a DF breaker. The issue comes in whether it is a single bathroom circuit or two bathroom circuit. In other cases, was power brought into the light box and branched out to individual outlets? Not as easy as a structure you wire yourself where you can have separate circuits for lighting and outlets. Some homes just make it more difficult.

    • @TwilightxKnight13
      @TwilightxKnight13 Рік тому

      With the elimination of incandescent lighting, it is much less of a problem. LED lighting should not be an issue for dual-function breakers. The bigger issue would be shared neutrals causing imbalances on the circuit.

    • @jonesgang
      @jonesgang Рік тому

      @@TwilightxKnight13 You have to use the more expensive breaker and that was my point. In some homes you have no choice but to use the more expensive dual-function breakers instead of the lesser alternatives to provide the adequate protection that the codes require.

  • @steveloux4709
    @steveloux4709 Рік тому

    I think your example of the GFCI receptacle behind the refrigerator fails to comply with 210.8, in that this location does not meet the definition of "readily accessible". So it really shouldn't be a matter of either locating it behind the refer or perhaps installing a DF breaker. Either the GFCI receptacle is not buried behind the refrigerator, or a DF breaker may be considered.

  • @ameador01
    @ameador01 Рік тому

    So to clarify, a dual function GFCI AFCI breaker is not the same as a combination GAFCI breaker? Also, do you have any videos that discuss troubleshooting an AFCI breaker? I just ran a circuit with (I''ll have to check) and combination breaker for a dishwasher. But, it is tripping even with the dishwasher is not plugged in. The conductors and ground are all testing as not having continuity with the hot wire. So not sure what it is picking up on. But, if I have the wires disconnected from the breaker, and only it's pigtail connected to the neutral bus, it does not trip. So it seems it doesn't like something about the wire run. But, I have also been told it may be the currently main breaker panel where this is connected, as it has the ground wires and neutral wires all intermixed over the 2 busses. The 2 busses are also jumped, so I didn't see why this would matter. Also had someone tell me to remove the bus jumper and connected all the grounds to the bus with the earth ground connected to it (going out to the ground rods), and to move the neutrals to the one without the earth ground. But also had others say that the 2 buses should be done where all the grounds are connected to the one with the earth ground, neutrals on the other, and still leave them jumped - that somehow this not being done could cause false trips of the AFCI break - but that doing this later patter would stop those false trips. The circuit was run with a 20amp breaker using MC cable to a metal outlet box with 12/2 wire. But not happy!

  • @SethEssington
    @SethEssington Рік тому +1

    I’d upgrade all my circuits to dual function breakers but they are expensive. I did upgrade my kitchen to a dual function breaker because I remodeled it. Now I’ve got a light switch at the kitchen entrance instead of the kitchen countertop and 3 prong receptacles(With new Romex) for my appliances.

    • @aurvaroy6670
      @aurvaroy6670 Рік тому +2

      If your house was built before all these code changes, then you don’t need to upgrade every single circuit to AF or DF. You only need to have AF or DF in any new circuit or modified circuit.
      So since you remodeled your kitchen, you did the right thing by upgrading its breaker to DF.

  • @tomasmerino1039
    @tomasmerino1039 7 місяців тому

    It's weird how complicated stuff is up there. Here in Argentina we have the line and neutral from the meter to a general thermo magnetic "breaker" which trips with overcurrent so your cables don't melt and also with shorts between live and neutral. From that to a differential that trips with ground derivations. Then you add smaller thermomagnetics for each individual circuit in the house, generally 10 amp for lighting, 16 amp for receptacles, and a 20 amp for special use receptacles like ovens and water heaters. And AC units are generally in a separate circuit too

  • @dwaynehast271
    @dwaynehast271 Рік тому +1

    Ive been replacing my 15/20/30 amp circuits with DF breakers, but what is everyone doing for the 50 amp ones? I interpreted My inspectors suggestion that I needed AF and GF for my dryer/ stove and HVAC unit as well. I can't find a 50amp AF anywhere.

    • @tomtom7955
      @tomtom7955 Рік тому +2

      in NE FL dedicated equipment circuits like refrigerators washers, dryers, ranges ect are still put on regular breakers , Probably because what a nightmare rollout arc fault breakers had, so many issues with those damn things in the beginning.

  • @Ash-pz6oy
    @Ash-pz6oy 9 місяців тому

    I just got a new fridge installed & it’s tripping the breaker multiple times a day, the old fridge was just fine.
    the current breaker running it is a CAFCI arc fault breaker and plugged into a regular outlet. Would swapping the breaker to a dual function breaker correct the issue?

  • @TheAkjody
    @TheAkjody Рік тому

    So now I have a thought... If I replace my old breakers, can I just can use only dual function arc-fault/GFCI circuit breakers and be done with it? Its my money I can waste it if I want to and provide the best of both worlds. And with Lowes and the 10% military discount. If I can replace them in a 1 for 1 is I am allowed to do that and not rewire the house. Seems like I can and still be in code?
    Seems like the cabling is all the same the difference is in the breaker if I finally understand it.

  • @andrewt9204
    @andrewt9204 Рік тому

    Inverter-based welders which most seem to be nowadays have the power supply and welding circuit separated so it won't trip AFCI. Well, assuming that their noise suppression circuit is up to snuff.

  • @JosephMilici
    @JosephMilici 5 місяців тому

    Another advantage of GFCI in panel is the ability to take a circuit tester and plug it into a receptacle and press the test button. Then you know you can work on that circuit and the correct breaker is off. Of course, verify, but this can save some back-and-forth to the panel.

  • @mr.c3928
    @mr.c3928 Рік тому

    Dustin, thank you and blessings to your family🙂🎄

  • @daktusdurggery5505
    @daktusdurggery5505 4 місяці тому

    So when do we use the ones that have the pigtail vs the ones that are plug on neutral without the pigtail?
    I have 2 20amp Dual functionCAFCI & GFCI, one for each side of my kitchen and I’m told fridge should not be on my of these protections due to minor faults being an annoyance trip and food spillage? Am I understanding this correctly?

    • @niktak1114
      @niktak1114 4 місяці тому

      You can only use the plug on neutral ones if your panel has the plug on neutral busbars

  • @ralphvickers2339
    @ralphvickers2339 3 місяці тому

    does the home run have to be afci protected , or can you use a afci receptacle as first point of the circuit

  • @ike7933
    @ike7933 7 місяців тому

    I am an appliance repair technician….i get so many nuisance calls due to the stupid GFI button being “ tripped” …..many people just remove them.
    Fun fact: …I have noticed that most manufacturer’s install manuals , specifically state to “ not put the fridge on a GFI….. amazing 😅 (I realize they do not write the electrical code fyi )
    I found an article about GFI’s a while back…..it was basically saying that some parts of the county have now gone away from GFI’s…( due to the nuisance tripping)

  • @ernstpeterlegrand
    @ernstpeterlegrand 4 місяці тому

    Act fault, ground fault ?mA, Type F/B, mcb, surge protector, voltage monitor relay, are there cases I put all of this in?

  • @sparky8910
    @sparky8910 Рік тому +1

    I gonna come down to a whole household sensored system. Smart programmable breakers are the next step.

  • @Logan-ix8vh
    @Logan-ix8vh Рік тому

    So if you put a dual function breaker on everything in the house at the panel, except for bathroom and garage and outside, can you just put regular plugs where GFI‘s are normally placed for example, the kitchen

  • @JeanPierreWhite
    @JeanPierreWhite Рік тому

    I agree with the inspectors. If you do a modification add AFCI at all appropriate locations on that panel or whatever. Why? Old wire is *more* likely to have a problem than a whole new electrical installation. AFCI's will detect dodgy old wiring with active arcing and prevent fires. It makes total sense to me.
    I am scoping out AFCI breakers for my home to be installed in an existing panel. I'm adding no wires, changing nothing. If something in the home works loose I'd prefer the breaker trip rather than the fire alarm go off just before we are about to die. Being an old panel with limited neutral landing spots I will have to be selective. The kitchen, living room and occupied bedrooms are a good start. Some protection is better than no protection.

  • @billthompson9482
    @billthompson9482 Рік тому

    When you are doing a service upgrade are you installing AF breakers on all of the existing Circuits? Or is this applying to new construction only? I am seeing a lot of Service upgrades not getting AF breakers installed in my area in Long Island New York.

    • @ericstandefer9138
      @ericstandefer9138 Рік тому

      If you upgrade you are supposed to make it code compliant with your jurisduction, but the cost of these are probably making people bypass it. In CA these dual functions are upwards of $100.

    • @TwilightxKnight13
      @TwilightxKnight13 Рік тому

      Always remember, the code is only as required as the AHJ (inspector) makes it. For various reasons, some legitimate, some not, many inspectors allow variations from the code. If your local inspector is not requiting AF protection, and the electricians in the area know that, it is likely they are going to save the cost and just install standard breakers.

  • @nicd5439
    @nicd5439 2 місяці тому

    Can dual breakers be in the main box where they share ground neutral buses?

  • @bassman87
    @bassman87 Рік тому +1

    Where I see this getting tricky is in multiuse areas such as a garage that has washer and dryers in them. (super common where I live) technically you don't need to arc fault protect garages, but you do laundry areas, so do you go dual function on the garage, or just the circuits the washer and dryer are on, ect. I guess this is more a question for my AHJ, but curious what others experiences have been.

    • @alphasaiyan5760
      @alphasaiyan5760 Рік тому

      Just gfci protection in the garage. It’s by location not equipment.

    • @bassman87
      @bassman87 Рік тому +2

      @@alphasaiyan5760 I can't say I 100% agree sense under article 100 a Laundry Area is defined as: Laundry Area. An area containing or designed to contain a laundry tray, clothes washer, or clothes dryer.
      I can see the argument by an AHJ that the equipment in the room is what defines the room. not the other way around.

    • @alphasaiyan5760
      @alphasaiyan5760 Рік тому

      @@bassman87 yes sir but it can be argued that a garage isn’t designed to be a laundry room and a laundry room is not designed to be a garage. I mean sometimes people have a washer and dryer in their garage but it doesn’t make it a laundry room. Some people could park a car in their laundry room but it doesn’t make it a garage.

    • @jfbeam
      @jfbeam Рік тому

      @@alphasaiyan5760 By the NEC's definitions, if you put a washer and/or dryer there, it's a laundry area - period. I've seen washer/dryer combos sitting on porches, in bathrooms, in closets, ... (mine are technically in a closet in a bathroom :-) 'tho I would agree, having a duct, hot and cold water taps, and a drain in that "closet" makes it a "Laundry Area") My grandmother's house had the washer in the bathroom, with the drain into the bathtub! (she didn't have a dryer)

    • @TwilightxKnight13
      @TwilightxKnight13 Рік тому +1

      and a "room" does not have to be defined by the walls. If you have an area of your garage that contains the washer/dryer, then you essentially have a dual-function space. The part dedicated to the laundry should be treated as such and likewise with the rest of the garage. You do not get to ignore whole sections of the code because you eliminate some walls. What about a truly open design house? What if all the living space is open and the only "room" separated by walls is the restroom? Does the entire house have to comply with the requirements of the kitchen? No, of course not. The same would apply to your garage, but of course the inspector (AHJ) has the final say. The code is merely a guideline. The inspector chooses what to enforce.

  • @joshbrown284
    @joshbrown284 Рік тому

    Can arc fault protectors reduce the risk of fire? For instance in a home that has older wiring is it worth investing the money in say dual functions breakers on particular circuits?

  • @rakentrail
    @rakentrail 3 місяці тому +1

    It's amazing, the house I was born in was built in 1950. No GFCI or AFCI. The house is still standing and not one person was ever electrocuted!

  • @schatzemanly6749
    @schatzemanly6749 Рік тому

    Thanks for down to earth videos

  • @robertsitch1415
    @robertsitch1415 Рік тому

    I do kind of wonder if hotels and simular businesses are more subject to the residential or commercial codes since people usually sleep there?

  • @DIYWithTheRichardsons
    @DIYWithTheRichardsons Рік тому

    What about using them on a house with a two wire system that doesn’t have a ground?

  • @qwiickk
    @qwiickk 9 місяців тому

    Good rationale with which to work!

  • @shelleysmith287
    @shelleysmith287 Місяць тому

    I have a sump pump in my crawl space of my cabin do I have to have gfci or duel breaker on that circuit

    • @okbrb
      @okbrb 23 дні тому

      Sump pumps are one of the few exceptions in the NEC and CEC

  • @marka8486
    @marka8486 11 місяців тому

    excellent instructor

  • @charlieperez6844
    @charlieperez6844 Рік тому

    Best channel EVER! Thank you

  • @keithclarkjr8443
    @keithclarkjr8443 Рік тому

    Can I use a dual function breaker in a house with electrical wiring that does not have a ground wires

  • @HongBoFerver
    @HongBoFerver 10 місяців тому +1

    Do you mean you are using the 2023 code book not the 2013 code book?

  • @foodsafetypragmatist
    @foodsafetypragmatist 10 місяців тому

    Truly enjoying your videos.
    Can you speak specifically to the differences between combination vs dual vs all-in-one breakers? I have an Eaton box. Finishing the basement and it seems to me the all-in-one breakers, although expensive, are the way to go.
    Last question - when using all-in-one breakers, is a GFCI receptacle still required for wet bar and bathroom outlets? Seems to me it’s duplicate. 🤔

  • @jenko701
    @jenko701 Рік тому

    A lot of food has been lost over gfci protection and I guess anything that can nuisance trip . In my own home I make sure my freezer does not have either. Yes I know , but my food is still frozen when I get home .

  • @Ariccio123
    @Ariccio123 7 місяців тому

    The only downside to GFCI breakers is that there are no audible alarm breakers, but there are plenty of audible alarm gfci receptacles on the market. It's an *amazingly* useful feature, I cannot say that enough!!

  • @gary4739
    @gary4739 Рік тому +1

    Why are you looking the 2013 NEC code instead of 2020 or 2023?

  • @Phil-D83
    @Phil-D83 Рік тому

    I used dual function on all the plugs and lights in house regardless. Overkill, but works. Did not do the fridge.

  • @EvendimataE
    @EvendimataE Рік тому +3

    if you will put afci breaker and add selected gfci receptacles, then that will be more exppensive than dual.....i rewired my house. i just put dual on all

  • @JeremyWashington1489
    @JeremyWashington1489 Рік тому

    It can be frustrating. I’m a second year apprentice in Montana and MT doesn’t require the kitchen to be arc-fault protected. So after pulling dozens and dozens of units, it wasn’t until my second year that I realized the code require kitchens to be arc-fault protected. Now whenever I have a test on the Code, I have to fight the instinct to put that kitchens aren’t included in AFCI locations. I know now that the Code says it, but it’s still hard to rethink something I’ve done hundreds of times.

    • @Jerry-rd9my
      @Jerry-rd9my Рік тому

      It sure is. State amendments vs NEC can be confusing at test time. I always mark any Code section(s) in my NEC with the highlighted word "AMEND" so I know to go to my printed list of state amendments that are approved for use in the PSI testing center.

  • @magnum12pm
    @magnum12pm Рік тому

    I have a garage with only 2 hots and a neutral running underground to a sub panel. The garage has a ground rod of its own and bare copper conductor ran into the sub panel. The sub panel neutral and ground are unbonded. Is this acceptable or Not? The Main breaker box has a 60 amp breaker that is feeding the garage subpanel.

    • @barelystablefarm7151
      @barelystablefarm7151 Рік тому

      Acceptable by today's standards? No. The ground needs to be carried all the way back to the main panel (4 wire) and if it's a detached structure it needs at least 1 ground rod (depending on resistance)

  • @TheMurfed
    @TheMurfed 10 місяців тому

    Well what about attics? there is alot of places my company will use standard single pole breakers.

  • @jeffreyrossman1083
    @jeffreyrossman1083 Рік тому +1

    Taking it a step further, dual function “receptacles” have saved my bacon with the limited space in my panel (old, unique size, limited circuit capacity). As the first receptacle in my SABCs and dedicated circuits, these meet code and allow me to use dumb double stuff overcurrent-only breakers in my panel, which gives me twice as many circuits!

    • @matt24fc
      @matt24fc Рік тому

      There is also a maximum amount of circuits you can install in a panel. Not just if you can fit them on the bus. Should be on the label inside the panel. I see that often. Here in Florida, you can't pass an inspection with any tandem breakers in a panel, rather you have to pass inspection and then go back and put any tandems in.
      Can't tell you how many times Ive opened a panel and found 10 or more tandem breakers, and now we have to add a much larger panel.

  • @q6906
    @q6906 Рік тому

    If A customer has a series of outlets that aren’t working and they think it’s a GFCI somewhere would replacing the circuit breaker with the door function fix that problem?

    • @tomtom7955
      @tomtom7955 Рік тому

      you would still need to find and replace the worn out gfci with a regular receptacle, the dual function breaker then provides the gfci protection. The reset button on a gfci is basically like a switch if you just change breaker and there is a bad gfci the current still wont travel past it to fed the rest of the outlets.

  • @ftShinanigan
    @ftShinanigan Рік тому

    Doesn't NEC require all 15/20a circuits in a dwelling to be AFCI protected?

    • @TwilightxKnight13
      @TwilightxKnight13 Рік тому +1

      Not all, but pretty damn close and every code cycle adds more. It will not be long before all dwelling circuits, inside and out, will require both AFCI and GFCI with the exception of circuits dedicated to a device whose very function creates arcs like a welder. Equipment/appliance manufacturers also have to continue to refine their devices to reduce/eliminate nuisance tripping if they want to sell any products.

  • @luismatias2910
    @luismatias2910 Рік тому

    Good explanation Mann!!! Thanks

  • @daveisthatkid
    @daveisthatkid Рік тому

    So I've ran into this issue this past year where an Afci keeps tripping, so I check all the devices, tighten up screws. Try to isolate what the problem is, but it's so intermittent what you think was the problem turns out it isn't and still trips. Almost give up and change to normal breaker. I open the cover move (the same breaker) to the bottom of the panel. Stops tripping. What could be the cause of that? Makes no sense to me.
    It's happened only 2 times ever to me, both Siemens panels, both in an orientation where we have a bunch of afci breakers in a row in the top left of the panel. Reseating didn't fix only moving to the bottom of panel. (Even on the same phase seemed to fix the issue)

  • @mathman0101
    @mathman0101 Рік тому

    Smart? you are alluding to machine learning or AI AFCIs . Arc-like signatures from inductive/capacitive (motors) and resistive loads (heating elements) as you suggests AFCIs are are being false tripped from arc like waveform signatures. Trip thresholds would also need to be adjusted. You really need good quality power quality meters and a higher sampling portable oscilloscope to capture and see these transients. Surge suppression can reduce some in-rush trips and other filtering can help but then your back to software to capture those false signals as opposed hardwired filters which may only pick-up specific arc like signatures rather than learn about a whole bunch of them depending on loads attached to branch circuits. Not sponsored but I have found the Leviton smartrip pro receptacle to be very good in removing false trips. The only thing that trips it every 6-months or so is the microwave I can live with that as it’s easy and quick to reset.

  • @ptrvljn
    @ptrvljn Рік тому

    Can I put AFCI+GFCI breakers on circuits that already include GFCI outlets, i.e. multiple GFCI protections?

    • @alphasaiyan5760
      @alphasaiyan5760 Рік тому

      That’s redundant

    • @stevensmith4099
      @stevensmith4099 9 місяців тому

      Yes you can. It won't hurt anything. Just more places to check if it trips.

  • @jb4241
    @jb4241 3 місяці тому

    Can one put 110V outlet on a country that uses 220V as there standard ?

  • @jeremyv2040
    @jeremyv2040 Рік тому

    dumb question...but can electricity jump from a connected 5/8 ground rod too a 1/2 grounding rod -not connected & underground? if so, will it still ground things out?

    • @TwilightxKnight13
      @TwilightxKnight13 Рік тому +1

      circuits are not generally completed through the earth

  • @matthewgregory8706
    @matthewgregory8706 Рік тому

    Dumb question, should I upgrade breakers to match code in home panel to make things safer because code changes and panels and electrical protection is now different when home was built

  • @KrazyKajun602
    @KrazyKajun602 Рік тому

    How about talking where or what you can use a standard breaker? Heat/Vent/Light?

  • @JohnThomas-lq5qp
    @JohnThomas-lq5qp Рік тому

    Read that they were having serious nuisance tripping AFCI problems with mini split heating cooling units so for awhile you do not have to install AFCI protection.

  • @emmanuelgutierrez8616
    @emmanuelgutierrez8616 Рік тому

    Just making sure, those dual function breakers were just for outlets series right? Not light and switches

    • @emmanuelgutierrez8616
      @emmanuelgutierrez8616 Рік тому

      Man, you said 2013 nec, that's been around long enough that i wish the DF breakers were cheaper already. Sounds like I'd have replace all my breakers. Hate they standardize the wrong breakers with a new electrical panel

  • @SamuelRamos-b2e
    @SamuelRamos-b2e 3 місяці тому

    Can you talk about temporary power pole …

  • @paulholmes1303
    @paulholmes1303 Рік тому +1

    Biggest issue I see with Arc Fault breakers is they still trip on wired, brushed power tools. I have to run a hundred feet of cord from a 'sane' outlet to run my circular saw, where ever I need it. I will NOT replace my wired tools as they give me reliable and 'always there' service, through the hardest woods. Battery tools (and I have lots) always have variable speeds through the life of the charge and that is visible especially with fine sanding and hardwood cuts. I do know they could factor out a brushed motor wave/noise profile, but only if someone else visibly pays for it. Oh Well.

    • @jamesmacdonnell4085
      @jamesmacdonnell4085 6 місяців тому

      Hi Paul, I feel the same as you, I have literally thousands of dollars invested in power tools with electrical cords. It would be way way too expensive to replace all those tools with brand new brushless motor tools. I have always preferred ac powered tools. I am having trouble finding discussions on this topic. Is there any type of repair kit to be able to use power tools with AFCI ? Hoping to find a solution, thanks for any suggestions. Jim

  • @jandgusletras9998
    @jandgusletras9998 Рік тому

    You are real master thank for ilustración

  • @vince6829
    @vince6829 Рік тому

    Thanks for sharing.

  • @johnnymalicoat754
    @johnnymalicoat754 Рік тому

    Do smoke detectors have to be afci protected?

  • @shadowgenesis2877
    @shadowgenesis2877 Рік тому

    About the false tripping of arc fault, seen it happen on a job site. High starting load motors such as a table or chop saw can trip them. So I learned from it that a "workshop", large corded tool, should use regular breakers. Now as you said about arc wielders, I can see that as time moves on and breakers get smarter the requirement for everything being on arc fault happening.

    • @curtisbme
      @curtisbme 8 місяців тому

      I've only seen this with my very old stuff. All the modern stuff does not seem to trip anything.

  • @timbreunung1359
    @timbreunung1359 Рік тому

    Would you or anyone, happen to know why the factory knockouts are offset on a 4x4 metal junction box on the 2 sides?

  • @TheAkjody
    @TheAkjody Рік тому

    I think I would feel better and make everything GFCI as I go along. I feal like every year or two I have to replace the GFIC breaker on the PED for my salt water pool. It has its own breaker. I would like to just change the breaker and be done with it.
    Really if there is an issue in the electricity it will help show the problems faster. I had a 50 youa garage burn down I think now after watching from parallel Arc to a nail that might have compromised a wire in the damp humid NC area. I think from the description a GFI would have tripped. I don't know the GFIC math yet to know. Anyhow... I am thinking unless running a brush motor I want everything upgraden and just label it to avoid confusion if a repair is needed. Even hair dryers are brushless arc free motors. Possibly my garage shed. My grinder could make a arc. I can have a arc friendly CI on the home that does not require a ext generator to use.
    Hopefully I think I am making smarter statements now. Chances are I still have this wrong. GFIC plug easy arms reach, everything on the dual breaker.

  • @billk8780
    @billk8780 Рік тому

    Dustin,
    At 4:17-ish you mention putting a refrigerator on an arc fault interrupter circuit. My home builder friend remodeled his own kitchen and dutifully installed an AFCI. Subsequently he had numerous nuisance trips on his new refrigerator. The local building inspector winked and said if it was his house he'd go with a ground fault interrupter on this dedicated circuit because the compressor motor causes the nuisance trips. Like to know others' experiences on this.

    • @RJ-ej1nr
      @RJ-ej1nr Рік тому

      Generally frustrated on nuisance tripping with AFCIs. Motors are typically where the issues are - primarily compressors, but I've seen other motors such as washing machines, shredders, and vacuum cleaners, along with a non motor device - space heaters. Even seen old desktop computers tripping them. Swapping with another AFCI breaker/device has a ~50-50 fix rate initially, but goes down to more like 25-75 over the long term. There's no way to keep a client happy with consistency like that.