Hello, I have a problem with my module and braking resistor, I hope you can help me, my module has the "ACT" LED always on, and I already burned the resistor, I changed the resistor for a new one but it always overheats, so I better disconnected the entire braking module, measured the voltage between the positive and negative connectors of the resistor and it always shows me 350V DC, even if the motor is stopped, it shows that voltage. Do you have any idea what it could be? Greetings and thank you very much.
Sir meri machine 230rpm par chalti hai .. or agr main uspr load dalta hun to wo 200 rpm pr ajati hai . Kya lgana hai usmn jo uski speed constant rhe ... Mene usmn vfd laga rkhi hai single phase ki.
When we give only input supply to vfd ACS800 used for EOT crane application,blast occur inside vfd and demage SCR and IGBT, although we do not give run command. What is the problem???
sir, i m having a Question that if we attached the (200 ohm 500 watt) two resistance in series and parallel then what was the value in series and parallel Sir plz help me out in this... thnx
If you connect 200ohm 500watt two resistor in series then your total resistance become 400ohm 500Watt and If you connect them in parallel then total resistance become 100 ohm 1000w.
Hai sir. 3 phase vfd not maintain the RPM. We saw the dc Link voltage is only 290 but other same Vfd are showing 590. It shows the error and the machine are not running.How I can increase the dc Link voltage?
Sir plz help me for EOT HOIST crane 20hp-20hp two vfd we are using in this application DBR must plz tell me value of DBR for vfd Delta c2000 series 15kw vfd
Very nice knowledge hum bahut din se confused the ki breaking resitance me dc kha se ati hai aj clear hua sir thanks
Very nice information sir
Very informative video's keep it up
Thanks
Good explain sir
Thank you
Excellent ❤
Nice info, thank you.
Sir breaking resistor ke parameters setting par video bnaye
Hello, I have a problem with my module and braking resistor, I hope you can help me, my module has the "ACT" LED always on, and I already burned the resistor, I changed the resistor for a new one but it always overheats, so I better disconnected the entire braking module, measured the voltage between the positive and negative connectors of the resistor and it always shows me 350V DC, even if the motor is stopped, it shows that voltage.
Do you have any idea what it could be?
Greetings and thank you very much.
Sir meri machine 230rpm par chalti hai .. or agr main uspr load dalta hun to wo 200 rpm pr ajati hai . Kya lgana hai usmn jo uski speed constant rhe ... Mene usmn vfd laga rkhi hai single phase ki.
Increase torque boost in your vfd.
@@niceelectronics9505 wo kese badhegi
Sir apka no. Mil sakta hai please
Send model no of vfd
អរគុណThank🙏
Sir 15kw ki vfd k liye kitne value ka DBR use kre
Application EOT HOIST crane k liye
C2000 Delta model vfd150c43a
When we give only input supply to vfd ACS800 used for EOT crane application,blast occur inside vfd and demage SCR and IGBT, although we do not give run command. What is the problem???
If continuity is getting in breaking resistor, is it defective or good? sir, please reply to me.
Good
sir, i m having a Question that if we attached the (200 ohm 500 watt) two resistance in series and parallel then what was the value in series and parallel
Sir plz help me out in this... thnx
If you connect 200ohm 500watt two resistor in series then your total resistance become 400ohm 500Watt and If you connect them in parallel then total resistance become 100 ohm 1000w.
Hai sir. 3 phase vfd not maintain the RPM. We saw the dc Link voltage is only 290 but other same Vfd are showing 590. It shows the error and the machine are not running.How I can increase the dc Link voltage?
Sir break resistance I have changed 4 times after 15 days same problem, resistance are damaged
Sir plz help me for EOT HOIST crane 20hp-20hp two vfd we are using in this application DBR must plz tell me value of DBR for vfd
Delta c2000 series 15kw vfd
Parameters settings in delta plc for use braking resistor
Please set Over voltage Stall Prevention off and AVR Regulation Off...For use of breaking resistor..
@@niceelectronics9505 😄 thankyou!!
Breaking register ke parallel me diode kyu lagaya hai
Interlocking??
Braking Resistor is optional if this is not in use(Not connect BRAKING RESISTOR) then any perameter changing to start VFD and MOTOR
sir or jaankari cahiya iske bare main.
Thanks
Okay thank you
Vai sedha bol na motor ka starting initial tork barane ke liye. Itna ghumata kiu hai
.vfd.soting.nikalna.ka.viode.banawa
Thanx Bhawaer Prajapat for your Comment. I will make VFD Reparing Basic video in few days.
Please speak with English language.I do not understand.
Your father is ingraj