Braking Resistor Connection in VFD|Use Of Braking Resistor In VFD| How Braking Resistor work in VFD|

Поділитися
Вставка
  • Опубліковано 12 січ 2025

КОМЕНТАРІ • 38

  • @shekhargeography1729
    @shekhargeography1729 4 роки тому +3

    Very nice knowledge hum bahut din se confused the ki breaking resitance me dc kha se ati hai aj clear hua sir thanks

  • @shivajibhandare5748
    @shivajibhandare5748 10 днів тому

    Very nice information sir

  • @ashishvitekar3474
    @ashishvitekar3474 4 роки тому +1

    Very informative video's keep it up
    Thanks

  • @dharmachinta7870
    @dharmachinta7870 2 роки тому

    Good explain sir
    Thank you

  • @naeemakram6797
    @naeemakram6797 Рік тому

    Excellent ❤

  • @sagarmadgundi3352
    @sagarmadgundi3352 4 роки тому +1

    Nice info, thank you.

  • @hukamsingh9298
    @hukamsingh9298 4 роки тому +3

    Sir breaking resistor ke parameters setting par video bnaye

  • @omargaray9457
    @omargaray9457 2 роки тому

    Hello, I have a problem with my module and braking resistor, I hope you can help me, my module has the "ACT" LED always on, and I already burned the resistor, I changed the resistor for a new one but it always overheats, so I better disconnected the entire braking module, measured the voltage between the positive and negative connectors of the resistor and it always shows me 350V DC, even if the motor is stopped, it shows that voltage.
    Do you have any idea what it could be?
    Greetings and thank you very much.

  • @n.b.d.sinjector2556
    @n.b.d.sinjector2556 3 роки тому +2

    Sir meri machine 230rpm par chalti hai .. or agr main uspr load dalta hun to wo 200 rpm pr ajati hai . Kya lgana hai usmn jo uski speed constant rhe ... Mene usmn vfd laga rkhi hai single phase ki.

  • @runbou3485
    @runbou3485 2 роки тому

    អរគុណThank🙏

  • @उपेन्द्रशिवराजचौहान

    Sir 15kw ki vfd k liye kitne value ka DBR use kre
    Application EOT HOIST crane k liye
    C2000 Delta model vfd150c43a

  • @atifshehzad2161
    @atifshehzad2161 3 роки тому

    When we give only input supply to vfd ACS800 used for EOT crane application,blast occur inside vfd and demage SCR and IGBT, although we do not give run command. What is the problem???

  • @devendrabhagat145
    @devendrabhagat145 3 роки тому +1

    If continuity is getting in breaking resistor, is it defective or good? sir, please reply to me.

  • @rewanshukasana3193
    @rewanshukasana3193 4 роки тому +2

    sir, i m having a Question that if we attached the (200 ohm 500 watt) two resistance in series and parallel then what was the value in series and parallel
    Sir plz help me out in this... thnx

    • @niceelectronics9505
      @niceelectronics9505  4 роки тому

      If you connect 200ohm 500watt two resistor in series then your total resistance become 400ohm 500Watt and If you connect them in parallel then total resistance become 100 ohm 1000w.

  • @Ajithkumar-qc7nl
    @Ajithkumar-qc7nl 3 роки тому

    Hai sir. 3 phase vfd not maintain the RPM. We saw the dc Link voltage is only 290 but other same Vfd are showing 590. It shows the error and the machine are not running.How I can increase the dc Link voltage?

  • @shaikehteshaam7255
    @shaikehteshaam7255 Рік тому

    Sir break resistance I have changed 4 times after 15 days same problem, resistance are damaged

  • @उपेन्द्रशिवराजचौहान

    Sir plz help me for EOT HOIST crane 20hp-20hp two vfd we are using in this application DBR must plz tell me value of DBR for vfd
    Delta c2000 series 15kw vfd

  • @freshlybrewedspells6652
    @freshlybrewedspells6652 4 роки тому +1

    Parameters settings in delta plc for use braking resistor

    • @niceelectronics9505
      @niceelectronics9505  4 роки тому +1

      Please set Over voltage Stall Prevention off and AVR Regulation Off...For use of breaking resistor..

    • @freshlybrewedspells6652
      @freshlybrewedspells6652 4 роки тому +1

      @@niceelectronics9505 😄 thankyou!!

  • @mausamdube4990
    @mausamdube4990 2 роки тому

    Breaking register ke parallel me diode kyu lagaya hai

  • @kumarnerella2122
    @kumarnerella2122 Рік тому

    Interlocking??

  • @gulshansaini5780
    @gulshansaini5780 2 роки тому

    Braking Resistor is optional if this is not in use(Not connect BRAKING RESISTOR) then any perameter changing to start VFD and MOTOR

  • @jaswantchauhan8826
    @jaswantchauhan8826 Рік тому

    sir or jaankari cahiya iske bare main.

  • @ahosanhabib1368
    @ahosanhabib1368 2 роки тому

    Thanks

  • @shaikmhabusubhani4013
    @shaikmhabusubhani4013 2 роки тому

    Okay thank you

  • @sudiptapanda2977
    @sudiptapanda2977 5 місяців тому

    Vai sedha bol na motor ka starting initial tork barane ke liye. Itna ghumata kiu hai

  • @bhawaerparjapat3859
    @bhawaerparjapat3859 4 роки тому +1

    .vfd.soting.nikalna.ka.viode.banawa

    • @niceelectronics9505
      @niceelectronics9505  4 роки тому

      Thanx Bhawaer Prajapat for your Comment. I will make VFD Reparing Basic video in few days.

  • @Bryanphyo7821
    @Bryanphyo7821 2 роки тому

    Please speak with English language.I do not understand.