Jab koyi option hi nahi bache Loco move hone ki waise condition me Loco ko fail karna hai. As for example 3 auxiliary converter hai, jisame koyi ak auxiliary converter isolate hua to koyi effect nahi parega. Jab two auxiliary converter isolate ho gaya to usaka troubleshooting karenge ab usame koyi ak bogie isolate karne se Kam chal raha hai to v loco fail nahi hoga, Load & Road permit nahi hua to Bankar dimand karna hai. Aage me power control us engine ko cut karke dusara engine attatch kar dega or us power ko Light Load formation me attached kar dega. Aapake Loco ka Jo v problem ho ushe power control ko bolana hai, or aapake power control hi dicison khud lega power fail karne ka.
🙏🙏 Sir, Good Afternoon. Sir, Bogie ko isolate karna hai, to Rotary Switch se kab karte hai, aur MCB se kab karte hai? Agar MCB se bogie isolate karna hai to kaise karte hai please bataye.👏👏
Sir bahut badhiya, isi trah pura 3-phase loco pda dijiye ,sab ka bhalai ho jayega
Han g👍
Thnku sir.. Itna achhe se btane k lie
welcome
Excellent isse achchha kuchh nahi
Thanks
very nice
Thanks
Nice sir
Thanks
Good
Thanks
Quick come to the point
Very good explanation sir👍
Thanks
Nice👌👌
Thanks
🙏🙏
Sir,
Please, ye bataye ki three phase loco kaun kaun se condition main fail kar sakte hai?
Jab koyi option hi nahi bache Loco move hone ki waise condition me Loco ko fail karna hai.
As for example 3 auxiliary converter hai, jisame koyi ak auxiliary converter isolate hua to koyi effect nahi parega. Jab two auxiliary converter isolate ho gaya to usaka troubleshooting karenge ab usame koyi ak bogie isolate karne se Kam chal raha hai to v loco fail nahi hoga, Load & Road permit nahi hua to Bankar dimand karna hai. Aage me power control us engine ko cut karke dusara engine attatch kar dega or us power ko Light Load formation me attached kar dega. Aapake Loco ka Jo v problem ho ushe power control ko bolana hai, or aapake power control hi dicison khud lega power fail karne ka.
Thanks, sir,,,🙏🙏
Barjesh bro super
Thanks
Bahut acha sir
Thanks
🙏🙏
Thanks Sir,
Bhahubt asani se samj me aaya.👏👏
Channel ka yahi udesh hai, Har topic ko easy banana, taki sabhi ko easyl samajh me aa jaye.
Sir , bahut achha laga
Thanks
Good job sir
Thanks
Really good
Thanks
Very nice❤
Thanks
Very nice trick sir
Thanks
Very good explanation
Thanks
Excellent 👍🏻👍🏻
Thanks
Bahut achha se bataye hai sir
Thanks
Very helpful sir🥰🙏
Thanks
Nice sir ji.
Superb and easy process
Thanks
Kya baat h sir ji ....maza aa gaya
Thanks
Sir. Bur 3. Isolated hone. Par. CHBA ka. Kam. 1 karega 2 ye. Nahi bataye
2 karega
Bahut badiya sir ji ese hi vidio banate rhe
Thanks
थैंक्स सर ❤️🙏
Thanks
Nice
Thanks
धन्यवाद 🙏
Very 🙏nice 🙏sir🙏🙏🙏
Thanks
Bahut hi Badhiya ekdam easy way me aapne samjhaya hai sir ,aapko kotishah Dhanyawad 🙏🙏🙏
Wah!! Kya bat hai
Thanks
👍 nice
Very nice sir
VeRy nice 👍
Thanks
Super boss
🙏🙏
Sir, Good Afternoon.
Sir,
Bogie ko isolate karna hai, to Rotary Switch se kab karte hai, aur MCB se kab karte hai?
Agar MCB se bogie isolate karna hai to kaise karte hai please bataye.👏👏
mujhe lga aap bahut old age the .. jab apki awaz sunte the ..😂😀
Old man ko hi jankari rahati hai kya ?😀😀
Sir abb loco me kitne processer hote hai
अच्छा बतलाते है मगर इस तरह से u tube पर लिखना की आज तक ऐसा कोई नहीं बतलाया होगा ये कुछ ज्यादा हो जा रहा है
😀😀 UA-cam par aisa bataya hai to batayiye.
Ok
Bahut bahut dhanyawad Bhai🙏🙏
Ab mujhe aachi tarah se samjh me aa gya
Very nice, thanks,
Please make a vedio with full details on multiple unit operation of 3 phase / conventional loco.
All ready video hai channel k play list me jakar dekhiye.