How to program your KUKA robot with mxAutomation in TIA Portal Tutorial

Поділитися
Вставка
  • Опубліковано 24 лис 2024

КОМЕНТАРІ • 32

  • @russellgee9349
    @russellgee9349 5 місяців тому +1

    Thanks so much for this. I've won a project on the basis of this. Now I have to make it work... I'd like to touch base with you on some of the details. Kind regards, Russ

  • @MrPromerican
    @MrPromerican 2 роки тому +1

    Very nice presentation. This should have more views. I subbed. Danke.

  • @ilyukchiljin7640
    @ilyukchiljin7640 Рік тому +1

    great video and i'm really impressed by the robot viewer on the WinCC unified. Did you build it with the Unity? It'd be great if there is a brief description on how you built the robot viewer section of the Dashboard.

  • @adamkubinsky7858
    @adamkubinsky7858 Рік тому

    Thank You The presentation is GREAT

  • @erickgarcia5408
    @erickgarcia5408 7 місяців тому

    I think there's an error in the approximation segment. When adding the approximation to corner 2, APO parameters should be PTP_MODE = 0, CP_MODE = 1, 0, .150, because it's a transition between a CP and a PTP movement, no the other way around. Correct me if I'm wrong

  • @WTEENG
    @WTEENG 2 роки тому +1

    Thank you for your wonderful video. 👍🏻

  • @cardinaldom574
    @cardinaldom574 Рік тому

    Very good video. Please hold can I get the simulation program to use. Am a Kuka Robot user at my place of work. Am very new to Kuka Robot and I really want to improve and catch up with my colleagues at work

  • @pasty734
    @pasty734 2 роки тому +3

    Hi! Thank you for your very informative video. Do you also have the project in previous versions of TIA Portal? I need the V16 but if you have any of the older it's the same since i can always upgrade them, thanks!

    • @furkangultek7069
      @furkangultek7069 2 роки тому

      You can check out this video, which is a simpler explanation. ua-cam.com/video/eg6vnXBNJWo/v-deo.html

    • @chrahi89
      @chrahi89  2 роки тому

      Sorry, but I program always with the newest version of TIA Portal.

  • @mirazizmirtojiyev7278
    @mirazizmirtojiyev7278 2 роки тому +1

    Thank you.It is very helpfull for me😀😀

  • @lemoncookie5515
    @lemoncookie5515 6 місяців тому

    Servus. Danke für deine Mühe.
    Hätte ne Frage bezüglich Minute 35:55
    warum fängst du da mit der Funktion KRC_Initialize an ? hat das einen Grund oder kann man auch mit einer anderen Reihenfolge fortfahren ?

  • @mrpraphartRompruek
    @mrpraphartRompruek 2 роки тому +1

    tqvm,this video help me so much

  • @_Iokanaan_Marusidze_
    @_Iokanaan_Marusidze_ 2 місяці тому

    Thanks

  • @said-ge6bl
    @said-ge6bl 3 місяці тому

    Hey, thanks for the video! Do you know if it is possible to get mxautomation working on OfficeLite, connecting to a real S7-1500?

  • @renatsagirov7094
    @renatsagirov7094 6 місяців тому

    Good afternoon! Please tell me how to establish a connection between Officelite and the plcsim tia portal?

  • @renatsagirov7094
    @renatsagirov7094 6 місяців тому

    I'm launching your unified runtime project, but I don't see the field as in the picture and the kuka robot how to set it up

  • @sudnifnatipac
    @sudnifnatipac 7 місяців тому

    very well done video!

  • @IP_work
    @IP_work 2 роки тому

    Thank you for sharing!)

  • @dershorty2000
    @dershorty2000 Рік тому

    Hello, nice Video, but where i can get kuka mxautiomation`? And when i Try to Start the mykrc-robot-web-viewer-app , then i get an Error Message... with an Index error. How can I fix it?

  • @jonathansegura9537
    @jonathansegura9537 Рік тому

    Great video, thank you

  • @magnusjohansson6884
    @magnusjohansson6884 2 роки тому +1

    Did you have any problem connecting PLCsim Advanced with Officelite? Anything you needed to do in Officelite to enable MXAutomation and the communication?

    • @chrahi89
      @chrahi89  2 роки тому +1

      Connecting PLCSIM Advanced with OfficeLite is probably worth its own tutorial. Took me quite a while to get it working, but the guys from KUKA helped me along the way. Once I knew how things work, starting a robot simulation became quite easy. Takes me only 1 min tops to have my simulation up and running.

    • @magnusjohansson6884
      @magnusjohansson6884 2 роки тому

      @@chrahi89 Did you write something up that you can share? I have a PLC project that runs a real Kuka but would love to have a set up in the office where I could simulate MXAutomation.

    • @chrahi89
      @chrahi89  2 роки тому

      @@magnusjohansson6884 Unfortunately I can not share the office lite image, you will have to ask KUKA for help. Furthermore, if you are using PLCSIMAdvanced instead of a physical PLC, you need the mxAutomation function blocks with enabled simulation access. And the KUKA Read and Write FCs all need to be edited, so they communicate via UDP instead of a hardware interface. Can only be done by KUKA since you need to remove the password protection from those FCs to edit them.

  • @davycroq6528
    @davycroq6528 Рік тому

    Very well done bro.

  • @metalhead2476
    @metalhead2476 6 місяців тому

    Are they using bezier to do the interp?

  • @HZ-yw4cb
    @HZ-yw4cb Рік тому

    Hello, I'm a student doing my thesis on the same topic as your video. At 51 minutes you say if the six numbers (311 311)don't match, it means something wrong with the configuration. there is always 322 320 with my PC, could you please tell me what is wrong with that, what should I do with the configuration? I tried many times the Problem is still there, thank you very much for the answer.

  • @nkululekoqaukeni4321
    @nkululekoqaukeni4321 2 роки тому +1

    can someone kindly explain to me the following terms,and their significance in the robot,,i am new in robots and i want to control my robot via siemens plc...i just want to get my robot sequence right.
    STOPMESS
    CONF_MESS
    DRIVES_ON
    DRIVES_OFF
    EXT_START
    RC_RDY1
    PRO_MOVE
    INT_E_STOP
    PERI_READY
    ON_PATH
    I0_ACTCONF
    USER_SAFE
    OPERATOR_SAFETY
    NEAR_POSRET
    PRO_ACT

  • @imadeddine6672
    @imadeddine6672 2 роки тому +1

    @chrahi89
    Helo Mr
    I m a automatique student , when i was reading a program for strapping machine i foun variable at this text %db3.dbw5
    Please sir can you explain this variable

  • @jbmxyz
    @jbmxyz Рік тому

    👍

  • @EPLSS
    @EPLSS Рік тому

    hello thanks a lot for this amazing video please can i contact you i have a few question about communication ethercat between plc and krC5