Wood stove with secondary burn. Chimney draft measurement, part 2

Поділитися
Вставка
  • Опубліковано 27 жов 2024

КОМЕНТАРІ • 22

  • @jeffreystroman2811
    @jeffreystroman2811 6 років тому +8

    Been using a federal airtight two years now (can't say enough good things about it, it totally rocks) with damper open. After two years i finally read the instructions after downloading them and they were so well written i decided to take the info to heart. Now i work damper settings into my routine of stove operation and have been able to achieve overnight burns w coals in the morning. Given that fully closed is still 30% open i do not believe it is enough of a "pinch point" to affect negative pressure, it's purpose is to reduce the cross-section of flue and therefore lower the rate of gasses, in my case allowing a more complete burn at the cat. Since every install is different and analog i do not claim to tell anyone how to best operate theirs, i only wanted to share my experience.

  • @davidferrell1876
    @davidferrell1876 5 років тому +2

    Presented like an engineer. You rock! Thanks for the excellent presentation.

  • @uprightfossil6673
    @uprightfossil6673 2 роки тому +2

    Completed 1@2. On to 3. I have a pipe for outside air to feed my stove so it isn’t pulling cold air through drafty walls and windows.

  • @Amotorcyclenut
    @Amotorcyclenut  6 років тому +1

    Look at Amazon for the best prices. They will bring it to your door.
    Amazon tools and parts link amzn.to/3OAo4pF
    #woodstoves #woodheat #woodheat
    Heat powered Stove Fan amzn.to/2gZdAS4
    Wood stove door gasket kit amzn.to/2kQJK6p
    Miracle Heat Reclaimer amzn.to/2looVNB
    Small Bellows amzn.to/2g6Urfk
    Super Splitting Axe amzn.to/2fXu4c5
    8-Foot Firewood Log Rack amzn.to/2gioWmR

  • @petergriffin1546
    @petergriffin1546 3 роки тому +1

    Goog video. I suggest a magnehelic to get accurate readings. Mine was off by .03

    • @Amotorcyclenut
      @Amotorcyclenut  3 роки тому

      Thanks for the tip! What does a Magnehelic measure?
      The Magnehelic gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems.

  • @divyabirsingh2905
    @divyabirsingh2905 Рік тому +1

    Wow

  • @gregfawcett5152
    @gregfawcett5152 Рік тому +1

    Seems like a good explanation but wouldn't outside air for both primary and secondary burns be more efficient as you are not taking the already warm air in the house and drawing it away for the combustion?

    • @Amotorcyclenut
      @Amotorcyclenut  Рік тому

      That is true, but that is not always a very convenient option.

  • @buzzsaw301
    @buzzsaw301 5 років тому

    I really appreciate this

  • @davidlisboa41
    @davidlisboa41 7 років тому

    Great video thanks

  • @petergriffin1546
    @petergriffin1546 3 роки тому

    Great video...You say not to use damper but what if your reading was all the way to the right on draft? In other words is there a time you would use a damper with a secondary burn stove?

    • @Amotorcyclenut
      @Amotorcyclenut  3 роки тому +1

      Not at all

    • @petergriffin1546
      @petergriffin1546 3 роки тому +2

      @@Amotorcyclenut thanks my draft is over .14 during a burn. and seems like its difficult to get slow flames without white smoke out chimney.

    • @Amotorcyclenut
      @Amotorcyclenut  3 роки тому

      how dry is your wood? Dry vs green firewood video
      ua-cam.com/video/D42LdYMFiK8/v-deo.html

    • @petergriffin1546
      @petergriffin1546 3 роки тому

      @@Amotorcyclenut I dont have any water but it measure from 12 to 18 percent but now im testing every piece sometimes the big logs are over 21 percent or 22 percent and a year old or kiln dry. In the middle. Kiln dry and craigslist mixing woods. but never any water out the end. chimney look good inside. Only way to control draft is damper. I guess ill know next year..

  • @petergriffin1546
    @petergriffin1546 2 роки тому

    So if your draft is .14 just leave it and not use damper?
    The damper does decrease pipe temp a lot.

    • @Amotorcyclenut
      @Amotorcyclenut  2 роки тому

      Yes but only until the chimney warms up, then it throttles down and the secondary burn kicks in and the pipe temp drops. The damper causes a pressure drop and I don't want that. I want as much vacuum in the stove as possible for the secondary burn to work. so I don't use the damper. I can get away with that because my pipes are welded and it is a air tight stove.

  • @SalmanSalman-iy3os
    @SalmanSalman-iy3os 5 років тому

    👍👍👍👍👍

  • @geraldmoore6257
    @geraldmoore6257 4 роки тому +1

    Virtually no explanation of anything. I know less now than before. Reading my comment, you might wonder what my issue was. Well now you know how I feel after having listened to the video.

  • @81eagle
    @81eagle 7 років тому

    I have never been a big fan pipe dampers.