ETAP Voltage Drop Analysis - ETAP Short Circuit Analysis In ETAP Course

Поділитися
Вставка
  • Опубліковано 13 гру 2024

КОМЕНТАРІ • 137

  • @EngrAhmedMahdy
    @EngrAhmedMahdy  4 роки тому +4

    🌟 Access 100+ courses, 1,600+ videos, and 300+ hours of professional lessons!
    Master electrical engineering, renewable energy, and much more with Khadija Academy Student Membership. Learn real-world skills through expertly designed courses on topics like:
    ✅ Solar Energy, Electrical Design, MATLAB Simulink, Power Electronics, Wind Energy, Wave Energy, and more!
    🔗 Explore it all here: www.khadijaacademy.com/p/khadija-academy-student-membership
    💡 Your future starts here-click to join now!

  • @MrOptimusPrime.
    @MrOptimusPrime. Рік тому

    Very simple. That's what I understood from this great video. Rate your equipment properly and you are good to go.

  • @nareshdadi1441
    @nareshdadi1441 5 років тому +4

    excellent explanation brother..
    i felt very happy and knowledgeable after seeing this video..
    would request you to upload such ETAP content with such an in depth explanation.
    Thanking you brother..

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому +1

      Thank you Naresh, you can find earthing system using Etap on the channel too.

  • @andraituazon617
    @andraituazon617 3 роки тому

    This is so lit, I like this video so much, so informative, In more than 30 minutes, I've learn the basic in ETAP, hopefully you've create more videos about this software. Thank you from Philippines

  • @dctayong14
    @dctayong14 3 роки тому

    My 35 mins definitely not put into waste. Thanks for the tutorial.

  • @Muhammadshafique-wg8zv
    @Muhammadshafique-wg8zv 5 років тому +1

    Excellent explanation sir, very helpful , I salute your effort

  • @suritisharma4687
    @suritisharma4687 5 років тому +2

    God bless you for such a kind work. Very helpful. Thanks for sharing

  • @mohammedangel5200
    @mohammedangel5200 5 років тому

    Your explanation is very good you made it very simple

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Thank you Mohammed, i am glad that you benefited from my video.

  • @omarazzam3103
    @omarazzam3103 5 років тому

    excellent and professinonal explanation
    waiting for more and more videos

  • @AJILAPEC
    @AJILAPEC 4 роки тому +1

    Very well explained!!! Continue it bro.. All the best!

  • @waqasahmed3768
    @waqasahmed3768 5 років тому

    Great Explanation... Really very much handy.. Salute you Bro. God Bless you for this kind work.

  • @achmadrifai8539
    @achmadrifai8539 4 роки тому +1

    Thanks for the explanation Sir...

  • @divakaranvp6459
    @divakaranvp6459 5 років тому

    Excellent presentation, in a simple way, to understand for anyone.Protective eqpt like MV & LV Breaker selection also to be added.

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Thank you Divakaran, you will find the selection of breakers and cables in our course for electrical design drawing on our academy website.

  • @AnilKumar-bu4qg
    @AnilKumar-bu4qg 3 роки тому

    Thanks for the lecture. Very nicely explained.

  • @MrBelal79
    @MrBelal79 4 роки тому +1

    Great Video Ever, I hope if you posted more on ETAP Design

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  4 роки тому

      Check our channel, there are more of them :)

  • @md.fardousealam6023
    @md.fardousealam6023 5 років тому

    I need more video about ETAP. This video is good I ever seen.

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Hi Alam, thanks for your comment :) , i will try to create more videos in electrical power engineering in the future inshaallah.

  • @mitalipandya2019
    @mitalipandya2019 4 роки тому +2

    Awaiting for the video tutorial on relay cordination using etap...please make it...

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  4 роки тому +1

      Sure brother, but it will take some time, there are videos in solar energy which are scheduled on UA-cam as I currently working on my master so I am pretty busy, but I promise to make it in the future.

  • @alainputrus1309
    @alainputrus1309 4 роки тому +2

    thanks for your clarification but i have one request can you compare this calculation with formula with my appreciate to benefit more

  • @mafizurr
    @mafizurr 2 роки тому

    super...excellent....Salut to you...

  • @rakeshenclave
    @rakeshenclave 2 роки тому

    Thanks for the nice video. Can you share some video for Arc Furnace, SVC & Statcom.

  • @rockyfeller1758
    @rockyfeller1758 4 роки тому

    Easy to understand, on points. thanks for the video

  • @harisali6379
    @harisali6379 5 років тому

    Great sir.
    Expecting more such videos.

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Thank you Sir, make sure to subscribe as i will keep uploading videos related to power engineering.

  • @reda.elgadi
    @reda.elgadi 4 роки тому

    Thanks a lot. This is really helpful

  • @syedmujtaba6496
    @syedmujtaba6496 4 роки тому +2

    Very well explained. Could you also please upload a video about modeling a hybrid microgrid on ETAP as it is becoming very common now a days?

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  4 роки тому +2

      Hi Sayed, I will save your request for future videos :)

    • @kiriellelilas
      @kiriellelilas 4 роки тому

      @@EngrAhmedMahdy Yes please this will make a highly interesting video!

  • @andraituazon617
    @andraituazon617 3 роки тому

    What base KVA can we assume? if we compute it manually?

  • @jananithiyagarajan5670
    @jananithiyagarajan5670 4 роки тому +1

    Amazing Video! Very well explained!
    Would have been better without ads in between. Too many ads distracting while trying to focus.

  • @trimafs
    @trimafs 4 роки тому

    Thank you very much for uploading

  • @girgisadly528
    @girgisadly528 5 років тому

    God Bless you . very helpful

  • @cadmentor4074
    @cadmentor4074 5 років тому +1

    thank you so much...............

  • @mustafaakkoyun1180
    @mustafaakkoyun1180 2 роки тому

    Hi sir, first thank you for the useful video then how can we find the transformer's grounding resistor value?

  • @MrUmarefarooq
    @MrUmarefarooq 5 років тому

    Thank you brother . god bless you

  • @alriashi7
    @alriashi7 11 місяців тому

    Thanks 😊 😊😊😊

  • @shahjahan3882
    @shahjahan3882 4 роки тому

    excellent video, can u please explain about number of conductors option while selecting cable from library? As you used 1Core Cables for all loads and similarly 1 Core Cable from the transformer?

  • @relienebraun9496
    @relienebraun9496 4 роки тому

    great video sir, this is what i need for trying simulation from real case.

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  4 роки тому

      Glad it was helpful!

    • @relienebraun9496
      @relienebraun9496 4 роки тому

      @@EngrAhmedMahdy so basically to solve voltage drop is changing tap rate on transformer by decreasing the primary and adding capacitor. what i need to know is why did you set the capacitor bank into 200 kvar, why ?

  • @rubenarancibia7145
    @rubenarancibia7145 5 років тому

    Etap can calculate interruptors?

  • @yahyarasheed6392
    @yahyarasheed6392 2 роки тому

    Nice presentation. However one question here. Why the cable model is not having the capacitance ? Cables have a non negligible value of capacaitance that has to be taken into account

  • @dreituazon9287
    @dreituazon9287 4 роки тому

    This is epic! Thanks a lot!

  • @fatohyhassan8880
    @fatohyhassan8880 5 років тому +1

    The cable is 4(4CX500+240)mm2, not 1C. You have choosed 1C, 0.7Kv, 500mm2, you should go to other choice for 4C not 1C. The arrangement of the cables from the single line diagram says FOUR CABLES each cable is 4C (FOUR CORE), not each is 1C. Your choice is right if it is 4(1CX500+240)mm2. Thank you for your effort.

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Hi Hassan,
      You didn't notice that there is another option called number of conductors per phase, you will see that it is written as 4 conductors per phase which provides for each phase a 4 conductors and our system is a three phase, so you will have the required number of conductors.

  • @agungpintar
    @agungpintar 4 роки тому +2

    how to solve voltage sag? using MGset (rotary UPS) on ETAP

  • @ayazahmadkhan9015
    @ayazahmadkhan9015 4 роки тому

    thanks a lot bro..
    allah bless u

  • @fattymind244
    @fattymind244 4 роки тому

    Thanks Bro, very helpful

  • @roshanshrestha9182
    @roshanshrestha9182 3 роки тому +1

    I was looking for a free electric system design course. Is there available

  • @aravindavimukthi4941
    @aravindavimukthi4941 Рік тому

    Hello.. I'm really interested about your video series. Wonderfully explained. However can you kindly explain the applications of 2C, 3C & 4C cable in the library? (one example will enough) (I have seen in the comment section questions about using 1C cable and I understand that it because of this is a single line diagram and we are considering only one phase)
    Thank you very much for your effort!

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  Рік тому +2

      Hey,
      Thank you for your nice feedback. I appreciate it.
      Let me explain this as many people are confused regarding 1/C, 2/C and these things.
      First, what does 1/C mean?
      1/C means that the cable has only 1 core, which means, if you have a three phase system, you will need 3 of 1/C cables to provide three phase power.
      If you enable the display of how many cables utilized in the display options of the load flow, specifically, in the tab "AC" and tick on "size" beside the cable. ETAP will show you how many cables are required based on your selection.
      3/C means that the cable has three cores, which means, in a three phase system, you will need only one of it to supply three phase power.
      In ETAP, if you selected the first option, you will find a number of cables written as 3-1/C which means that ETAP selected 3 of this single core cable to supply electrical power. However, if you selected 3/C, you will find it selected only one, as it is enough for the system.
      2/C means 2 cores in one cable, 4/C means 4 cores, and so on.
      The neutral is not shown in the main library from what I remember.
      If I remember correctly, the neutral is added separately from the tab "Configuration" in the cable settings, then selecting the neutral from the auxiliary library with the size needed.

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  Рік тому +2

      I just checked out on ETAP, if you choose 4/C, then you can have three cores for the three phase system and the fourth one can be neutral or protective earth. This can be set from the "Configuration" menu in the cable itself by selecting the neutral as main cable.

    • @aravindavimukthi4941
      @aravindavimukthi4941 Рік тому

      @@EngrAhmedMahdy Thank you for the explanation.

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  Рік тому

      You are welcome anytime

  • @powertechedu5017
    @powertechedu5017 4 роки тому

    nice

  • @andraituazon617
    @andraituazon617 4 роки тому

    Let me ask you, Why their was No Cable between Power Grid and Transformer ? in your SLD it is directly connected as the bus?

  • @darrenroydelaminez1008
    @darrenroydelaminez1008 4 роки тому

    Why those protective device(ACB,MCCB) not inserted in etap unlike in autocad?

  • @mbasikander
    @mbasikander 5 років тому

    Good explanation, really helpful. Furthermore Is there any method to open etap 16 file in older version?

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Thank you Malik, i haven't tried opening new version files in older Etap but if i didn't work, i think you have to do all the calculations and information addition again to the program.

  • @thinkseeeatthroughvickus4555
    @thinkseeeatthroughvickus4555 4 роки тому

    can you advice X/R ratio for each voltage level. (as u advised x/r = 10 for 11KV)

  • @marcozanotti15
    @marcozanotti15 4 роки тому

    Hi, how can i add ground resistance for line ground fault calculation? thanks

  • @MudasirHussain-o9s
    @MudasirHussain-o9s 5 років тому +1

    Sir can I use this software in my pc

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Yes sure, it is for pc only

    • @MudasirHussain-o9s
      @MudasirHussain-o9s 5 років тому

      @@EngrAhmedMahdy please send me link on mudasirgurezi123@gmail.com

    • @MudasirHussain-o9s
      @MudasirHussain-o9s 5 років тому

      Please send me link for download this I need it... please
      My Gmail account mudasirgurezi123@gmail.com

  • @rehanshahid9313
    @rehanshahid9313 5 років тому

    Hi Ahmed - Can we draw busways instead of cables in etap?

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Yes, by using busducts in Etap which is the busways.

    • @rehanshahid9313
      @rehanshahid9313 5 років тому

      @@EngrAhmedMahdy but there is no option for current rating in busducts

  • @hanyharby1355
    @hanyharby1355 4 роки тому

    in bus editor, load diversity factor is not activate for any changing. why

  • @umaimaayesha3432
    @umaimaayesha3432 5 років тому

    Dear sir.. Trail version showing only limited function
    I want to completepackage of ETap software . How much does it costs?

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      700$ per license or you can search for full version download on the internet :'D

  • @KyawMyo
    @KyawMyo 5 років тому

    where can i find etap software?

  • @muqtardm
    @muqtardm 6 років тому +1

    PLEASE CAN YOU SHOW HOW TO ADD A 630MM 1C ALUMINUM 400V,60HZ CABLE WITH ALL PARAMETERS

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      I think in order to add it to the program, you need to know all the details as X and R equivalent of the cable from the catalog of the cable company.

    • @kiethdarylcampaner9359
      @kiethdarylcampaner9359 4 роки тому

      customize the library

  • @supernova77ful
    @supernova77ful 5 років тому

    Hello and good day sir. Can you please make a video for IEEE 9 bus system?

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому +2

      Hi Poseidon,
      I will take SC for your request for future videos.

  • @fardanfardann2322
    @fardanfardann2322 4 роки тому

    Thx, I have one problem, when I select a cable of 3cx300sqmm and run the short circuit analysis and error comes up (the zero sequence is =0), even for cables like 185sqmm or 500sqmm, how we can solve this?

    • @usmansaleem456
      @usmansaleem456 4 роки тому

      comlete course on ETAP
      lyskills.com/courses/etap-updated-courses-1

  • @noorelahi5454
    @noorelahi5454 4 роки тому

    Sir, its Incredible , but i want to that can i import the data from Autocad to E Tap ,,, Suppose I am interested to Import the SLD from CAD to ETap ,How can i do that.......??????
    Thanks,
    Noor(EDE)

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  4 роки тому

      Hi Noor,
      On File menu use Data Exchange, however you can not direct import the ACAD file. You need to change the ACAD file to XML file and then you can import that SLD in the XML format. There is a help tool on this, press F1 for more details.

  • @rockyfeller1758
    @rockyfeller1758 4 роки тому

    Can you do also Protection coordination using ETAP

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  4 роки тому +2

      Hi Rocky, I will save your request for future videos, it seems many people are asking for protection coordination.

    • @rockyfeller1758
      @rockyfeller1758 4 роки тому

      Thank you for taking notice sir, keep it up. You vlog is a big help

  • @ahmedazhri9126
    @ahmedazhri9126 4 роки тому

    ياباش مهندس هل الايتاب بيعمل Coordination. Study

  • @kiethdarylcampaner9359
    @kiethdarylcampaner9359 4 роки тому

    Can you have a tutorial about the protection coordination

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  4 роки тому +2

      Hi Kieth, I will save your request for future videos :)

    • @kiethdarylcampaner9359
      @kiethdarylcampaner9359 4 роки тому

      Khadija Academy Thank you so so so much!! It's a big help for my thesis this year. I wanna learn also about the concept of MVAR CONTROL - VOLTAGE CONTROL in etap thank you.

  • @sheharyarkhan4429
    @sheharyarkhan4429 3 роки тому

    Brother can you provide a link to download etap 12.6 plz?

  • @ayoubissgane9069
    @ayoubissgane9069 5 років тому

    hi can you give us the serial number of etap 12.6.0

  • @ganeshamoorthi3322
    @ganeshamoorthi3322 3 роки тому

    Hi boss, it seems, it has mistake in selection of cable, instead of selecting 4 core cable you are always selecting single core cable from the beginning.

  • @waqasahmed3768
    @waqasahmed3768 5 років тому

    how can i do this etap complete course for power analysis?

    • @waqasahmed3768
      @waqasahmed3768 5 років тому

      i mean online

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Hi Waqas, if you are talking about Etap as program online, i don't think it is possible, you have to install it on your PC.

  • @arafatbaunto4068
    @arafatbaunto4068 4 роки тому

    Why you didn't include the Circuit Breakers in your etap presentation?

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  4 роки тому

      Well, it wouldn't affect the short circuit or the voltage drop analysis, we already selected the components in the single-line diagram of Autocad, this was a part of the electrical design course.
      www.khadijaacademy.com/p/khadija-academy-student-membership

  • @prasenjit_hazra
    @prasenjit_hazra 2 роки тому

    Good Presentation. But I miserably failed despite several attempts of the same. Why are you missing the point of ACB.

  • @derfdsfsdqfsdsdsd
    @derfdsfsdqfsdsdsd 5 років тому

    why you didn't calculate peak short circuit ?

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Because our components ratings in case of short circuit are designed based on the rms or the effective value of s.c current not the peak value.

  • @SANGAMEWORLD
    @SANGAMEWORLD 5 років тому

    You should select 4c cable not 1c cable for transformer

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      In the catalogue there is no 4 core cable of 500 mm2, only single core , so we took 4 of that single core.

    • @SANGAMEWORLD
      @SANGAMEWORLD 5 років тому

      @@EngrAhmedMahdy when you will take 3c cable?, What is the difference between 3c and 1c cable in etap calculation?

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      @@SANGAMEWORLD if it is available i will take 3 core, the problem is 500 mm2 is a large cross section area , so if you want it as a 3 core then it will be very costly and it will be very bulky and difficult to install , in case of lower cross section areas we can use single core, it is of course preferred to use three core but in some cases we are forced to have single core.

    • @fatohyhassan8880
      @fatohyhassan8880 5 років тому

      Yes, I agree with you totally.

  • @kipngenovincent5970
    @kipngenovincent5970 8 місяців тому

    Can i download a cracked version of etap?

  • @arafatbaunto4068
    @arafatbaunto4068 5 років тому

    Great Explanation. and Free. Some ETAP training will cost you 5000$ for just 1 topic. what a waste

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Yup ETAP is expensive but we have to spread knowledge as not everyone can afford that much money.

    • @arafatbaunto4068
      @arafatbaunto4068 4 роки тому

      @@EngrAhmedMahdy GOD bless you brother.

  • @احمدالجبوري-ط4و
    @احمدالجبوري-ط4و 5 років тому

    the picture not ok

  • @tarekelbiyaly7073
    @tarekelbiyaly7073 4 роки тому

    Where is the circuit breakers ?

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  4 роки тому

      They are in the diagram, you can see each line contain a switch and beside it a number which representing number of amperes, this is our circuit breaker.

  • @yasmindesyria2771
    @yasmindesyria2771 5 років тому

    4 set"s mean 4 nos of 4x500mm^2 cable u confuse me with your S E T

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Hi Yasmin,
      I looked back to the video just to catch where i said "set" but i did not find it :'D, 4(4*500) means 4 conductors of R and 4 conductors of S and 4 conductors of T, each of 500 mm^2 and 4 conductors of neutral, hope it is clear now :'D

    • @yasmindesyria2771
      @yasmindesyria2771 5 років тому

      @@EngrAhmedMahdy for the 1000kva transformer the secondary current will be 1520Amp in this case we use 4x(4x500+1x240)the first four we call it sets number its like 4 cable of 4*500 on parallel to share the load because one cable of 4*500 mm not suitable to carry the load i wish its clear

    • @EngrAhmedMahdy
      @EngrAhmedMahdy  5 років тому

      Yes, you can say 4 sets or 4 parallel cables, they are the same 😤😏