5 tips for Rough-in Phase on New Construction. Electrical wiring.

Поділитися
Вставка
  • Опубліковано 24 січ 2023
  • We offer the #1 Electrical Exam Prep Program
    FREE VERSION
    electricalcodecoach.com/free-...
    PRO VERSION
    www.electricalexamcoach.com/m...
    USB OR DVD PROGRAM FREE SHIPPING!!
    electricalcodecoach.com/shop/...
    400x Practice Exam PDF Download for only 14.99 electricalcodecoach.com/shop/...
    2017 Tabs with FREE SHIPPING
    electricalcodecoach.com/shop/...
    2020 NEC TABS with FREE Shipping
    electricalcodecoach.com/shop/...
    2023 NEC TABS with FREE SHIPPING
    electricalcodecoach.com/shop/...

КОМЕНТАРІ • 49

  • @sparks277
    @sparks277 11 днів тому

    Dude... I'm a 24 year journeyman commercial electrician with my fair share of residential work. I won't lie, we look down on residential, but you've really got your act together! That's some of the best tips I've ever heard.

  • @barnproductions
    @barnproductions Рік тому +21

    Yes, please make a second video discussing what one should charge for rough in / trim out

  • @jamieearl6611
    @jamieearl6611 Рік тому +1

    Awesome vid , Coach. Thank you.

  • @MrKen59
    @MrKen59 Рік тому +2

    Awesome tips - Thank You 🙏

  • @jrpritchard1622
    @jrpritchard1622 Рік тому +1

    thanks coach on the tips

  • @slimydee5173
    @slimydee5173 Рік тому +1

    Thank you, more like this 👍

  • @shawnkegel6526
    @shawnkegel6526 Рік тому +1

    Thanks !!

  • @chrispate2788
    @chrispate2788 Рік тому

    Coach GREAT idea on making this tips vid 👌, thats why your THA MAN, THANKS 💪

  • @rapierville
    @rapierville 6 місяців тому

    Great pointers! Thanks.

  • @dansklrvids7303
    @dansklrvids7303 6 місяців тому

    Outstanding advice!!

  • @estevaness
    @estevaness Рік тому +3

    Nice 👍 I make up switch boxes and receptacles on rough in… in my jurisdiction we have to land grounds and neutrals only for rough in.. I’ll mark the outer sheathing and leave it on the hot conductors until final termination , of course this is all de energized.

  • @davidlang576
    @davidlang576 Рік тому +1

    Thanks

  • @rupe53
    @rupe53 Рік тому +9

    Nice idea on taking pictures. My boss used to do that and always lost track of which job was which. I told him to take a shot of the mailbox # or the outside of the house before going inside. That helped quite a bit. You can also add sticky notes on the wall to identify which room or which direction the shots are. (front bedroom, north, south, etc) Just one per room or in any other confusing situation will do.

    • @kevinthompson4690
      @kevinthompson4690 Рік тому +1

      I insert cardboard in my interior panels and write the address or lot number on it in sharpie along with how many cans, etc. Then I start a video with that as a sort of thumbnail. when strolling through pictures I can see which house it is.

  • @Gabriel-jc2sc
    @Gabriel-jc2sc 4 місяці тому +1

    Great video!💪💪

  • @stevecampbell3986
    @stevecampbell3986 Рік тому +2

    I am an east Tenn electrician I do not pull a finish permit or service release permit under my license unless I do the work, and the inspector also knows . That way, you may not finish the house, but you are released from the ownership of liability of someone else's work. Always let the power provider know that you refuse to be liable, and demand that they record who pulls finish/ service release permit. It is a matter of public record, and be of great value to you in case of future problems. document all pertinent info! I also take photos, I have had outlets covered up!! Thats what drywallers do!

  • @tomcarrigan902
    @tomcarrigan902 Рік тому +1

    Great information, thank you.

  • @knobntube5515
    @knobntube5515 Рік тому

    If you have a choice for rough in, do you prefer to start after all plumbing and hvac? Do you write that into your contracts?

  • @michaelwickham2003
    @michaelwickham2003 Рік тому +1

    How do I deal with changes at the trim out

  • @coreyfranco7060
    @coreyfranco7060 Рік тому +1

    I been landing boxes behind the kitchen sink, mounted so front of the is 1.5" or so proud of the framing. Cabinet installer is forced to cut it in...

  • @JuanLopez-wp2oz
    @JuanLopez-wp2oz Рік тому +2

    For the vanity wires you should manor an S shape loop, much more better

  • @Avotts
    @Avotts 6 місяців тому +1

    I need help in repairing doublewide. PLEASE.

  • @bluecollarbones
    @bluecollarbones 5 місяців тому +1

    Why are You running 12awg for lights?

  • @dant2421
    @dant2421 Рік тому +2

    DIY question. For rough ins does the sheathing on the romex wires in the outlet boxes have to be trimmed to code or is it more common just to roll up romex and tuck in box. Yes, I'm getting inspected.

    • @hvacmisadventures
      @hvacmisadventures Рік тому +2

      Skin it back and fold the wires back into the box. Make sure you leave your 6 inches

    • @detroitcowboy1313
      @detroitcowboy1313 Рік тому +1

      Yes , but leave enough skin to protect the wires entering the box , I’ve seen em short at at that point , especially going into a metal box using a Romeo connector

  • @simplewick350
    @simplewick350 Рік тому +1

    On the point of leaving wire in the wall for vanity lights, whats your solution when center of your cut in box ends up right on the plumbers pipe?

  • @davep8366
    @davep8366 Рік тому +1

    I will staple my wire (that is to be pulled out) to the FRONT of the stud so whoever is hanging drywall they have to remove it to hang board...I works about 90% of the time...LOL

  • @thetruth4519
    @thetruth4519 Рік тому +1

    How far is the cable supposed to be stapled away from the face of the stud so a drywall screw will not hit it?

    • @KLAWNINETY
      @KLAWNINETY Рік тому +1

      1 1/4" or you have to use a nail plate

  • @anthonyelectric6045
    @anthonyelectric6045 Рік тому

    Was the 12 gage wire a bulk cost thing or do you use it as your practice? I wish when we did condos and houses years back-don’t laugh coach- that we had pictures like you were saying. Avoiding lots of finger pointing etc. great video 👍

  • @bend4236
    @bend4236 Рік тому +2

    Unfortunately there are some inspectors in my area that will not pass a rough end if you do not have the vanity light in a box

    • @Kyohan137
      @Kyohan137 Рік тому +1

      We dealt with one of those and could not get him to understand the rationale for floating the wire so we had to box up to pass than remove the boxes before the drywall was installed

    • @kevinthompson4690
      @kevinthompson4690 Рік тому +2

      yes I have same issue. We install pancake boxes where the mirror is to be installed, once we get on site remove pancake box, install cut in box where vanity lights are to be then cover hole with mirror.

  • @lestersteele7509
    @lestersteele7509 Рік тому +4

    No 15 amp circuits ?

    • @rupe53
      @rupe53 Рік тому +2

      If you look at the big picture on cost, it only saves a few bucks on a new construction job. Why bother? Yeah, certain appliances like a furnace only need 15 amps, but you can always downsize the breaker.

    • @Dezeberbro
      @Dezeberbro Рік тому +1

      Might be the specs

    • @dgibson6147
      @dgibson6147 Рік тому +1

      Same question. Do you always run 20 amp circuits in all your home's?

    • @kevinthompson4690
      @kevinthompson4690 Рік тому +1

      Some municipalities where I am from do not let you use 14 gauge wire. He may be in one of these, NEC allows it and I use it whenever I can.

    • @coreyfranco7060
      @coreyfranco7060 Рік тому +1

      @@kevinthompson4690 Las Vegas residential use receptacles are all 20a and it does cost alot more...

  • @leyking31
    @leyking31 Рік тому +1

    🐾⚱️

  • @teraxiel
    @teraxiel 10 місяців тому +3

    Haha, you're in one of those silly jurisdictions that doesn't allow 14-2 I assume?

  • @jett762
    @jett762 Рік тому +1

    must be hourly electricianz

  • @rodneyrtennis1279
    @rodneyrtennis1279 11 місяців тому

    Plumbing Top Out: Failed! Not one mid-story guide anywhere.