Schenider M241 PLC Firmware Update

Поділитися
Вставка
  • Опубліковано 23 січ 2025
  • Hi Friends,
    Feel free for any question.
    Like My Facebook Page
    / industrial-a. .
    Also follow us on UA-cam for more update
    / kunalshah_ias
    Thanks

КОМЕНТАРІ • 13

  • @davidmartinezgamero3803
    @davidmartinezgamero3803 Рік тому +1

    hola, existe alguna forma de formatear la tarjeta SD de un PLC241 de manera remota

    • @KunalShah_IAS
      @KunalShah_IAS  Рік тому

      Hello, No I don't think it is possible. Because no access SD card through PLC or Internet. You just remove it , insert it in Laptop and format it. Good Luck

    • @KunalShah_IAS
      @KunalShah_IAS  Рік тому

      product-help.schneider-electric.com/Machine%20Expert/V1.1/en/m241prg/m241prg/SD_Card/SD_Card-3.htm

  • @nvtai11d3
    @nvtai11d3 4 роки тому +1

    how about warning? " Post configuration warning" . i can't change ip with error. plz help me, thanks.

  • @Muskaninternet
    @Muskaninternet 2 роки тому +1

    Fiber fox software de sakte ho

  • @MrGuiSlash
    @MrGuiSlash 4 роки тому +1

    Hello mate! Let me ask you, are you connecting the ethernet cable to Ethernet_1 or Ethernet_2? When I try to connect to Ethernet_1 the software doesn't show anything to me, but when I connect to Ethernet_2 it shows the IP. Do you have some advice to me? What is happening to my Ethernet_1? Thank you!

    • @KunalShah_IAS
      @KunalShah_IAS  4 роки тому +1

      Hello, I can not understand your question.. If you have Model M241 then , there is Front side RJ45 used as Ethernet Network while the top side RJ45 used as Serial Link Port (RS232 or RS485). Still you have any doubt then let me know , I will try to solve it. Thank You.

    • @MrGuiSlash
      @MrGuiSlash 4 роки тому

      @@KunalShah_IAS Sorry, the model of my plc is the TM251MESE, do you know this controller?

    • @KunalShah_IAS
      @KunalShah_IAS  4 роки тому +1

      @@MrGuiSlash Hi, You can try this.
      Cause
      : The memory register on the PLC that EcoStruxure Machine Expert gets the value from in order to populate the IP_Address column from contains only the primary IP Address of the PLC which is tied to Ethernet_1. Ethernet_2 is originally designed to be on a different subnet than Ethernet_1 for a Device Network, but also has the ability to be used as a point of connection for configuration from EcoStruxure Machine Expert.
      Note: This applies to TM4ES4 Secondary Ethernet modules for Modicon M241.
      Resolution
      Keep a record of IP Addresses tied to Ethernet_1 and Ethernet_2 for your PLC(s). Be aware of this behaviour in the Communication Settings (Controller Selection in SoMachine) tab screen when you connect to the PLC.
      If you use the setting "Connection Mode -> IP Address" at the bottom of the Communication Settings tab screen, you can still enter the IP Address of Ethernet_2 to connect to the PLC.

    • @muriithikiragu2932
      @muriithikiragu2932 4 роки тому

      @@KunalShah_IAS could help with M241 firmware version 4.0.5.20 and below please

    • @KunalShah_IAS
      @KunalShah_IAS  4 роки тому

      @@muriithikiragu2932 I will try.. What's your requirement?