SF6 Circuit Breaker Part 1 Operation, Arc quenching inside interrupter with diagram explained

Поділитися
Вставка
  • Опубліковано 3 сер 2024
  • In this video, SF6 Circuit Breaker is discussed with respect to following points.
    1. Identification of Components
    2. Main and Arc contacts identification along with internal parts of interrupter
    3. Close and Open operation with diagram
    4. Arc quenching process
    5. SF6 gas Properties
    6. Arc Contact function and composition
    For Business inquiries please mail to: tektalksengineered@gmail.com
    Video URL: • SF6 Circuit Breaker Pa...
    #sf6circuitbreaker #sf6circuitbreakeroperation #sf6properties #sf6interrupter

КОМЕНТАРІ • 43

  • @Noah00008
    @Noah00008 4 роки тому

    Thanks for your video! It's very helpful to me!

  • @bengalilonda3556
    @bengalilonda3556 4 роки тому

    Thanks for this video

  • @klam77
    @klam77 Рік тому +1

    Fascinating. Great explanation even though it's robot voiceover.

  • @pradeepraghavan2109
    @pradeepraghavan2109 4 роки тому +1

    VERY HELPFUL, THANKS FOR YOUR VIDEO

  • @surendrakverma555
    @surendrakverma555 3 роки тому +1

    Very good. Thanks

  • @DJCNU
    @DJCNU 4 роки тому

    Thanks for video

  • @legendarygamerprince5317
    @legendarygamerprince5317 3 роки тому +1

    Thx for this video

  • @bramhadeosawale9187
    @bramhadeosawale9187 2 роки тому +1

    Excellent

  • @hamidmoulla4716
    @hamidmoulla4716 4 роки тому

    Vers good

  • @chhayashinde82
    @chhayashinde82 3 роки тому +1

    What happens when we try to extinguish arc, without weakening the arc or when arc is strong In ckt breaker #ratnadipshinde

  • @lucioguevara-mendoza5096
    @lucioguevara-mendoza5096 4 роки тому

    What happens when rupture disc breaks, breaker trips, and one or both poles remain energized? Would there be an internal fault with 0 SF6 pressure?

    • @ElectroGlobe1
      @ElectroGlobe1  3 роки тому +1

      If SF6 is at zero level. Any breaker operation whether close or open, should not be done in loaded condition. first load should be taken out of breaker circuit.

  • @radosawhabdas7666
    @radosawhabdas7666 Рік тому +1

    Does the SF6 reading which you show on gauge shows the pressure in the gas tank itself or gas in whole CircuitBreaker chamber? Is there a difference to that?
    What does high reading/low reading on it means? I read out that the leakage might lead to the gauge pressure reading dropping, but that would mean that the pressure outside of tank would rise?
    What would the high reading indicate?

    • @ElectroGlobe1
      @ElectroGlobe1  Рік тому

      SF6 pressure gauge shows the pressure inside circuit breaker. Low pressure means the pressure inside the breaker is dropped.

    • @radosawhabdas7666
      @radosawhabdas7666 Рік тому +1

      @@ElectroGlobe1 Thanks for the fast response, so its not the pressure of the SF6 gas tank per se but the whole closed circuit in which the gas can cycle?
      What happens when pressure of this gas increase? In what scenarios it could happen?

    • @ElectroGlobe1
      @ElectroGlobe1  Рік тому

      @@radosawhabdas7666 Yes it indicates the pressure of complete gas pipes. High pressure than the recommended level can cause leakage.

  • @raosadaqat2531
    @raosadaqat2531 3 роки тому +1

    sir we have gis system but there is some lekeage observed of sf6 gass from bus bar isolator compartment between breaker and isolator sir gas lekage observed from nutbolt what can ido now plz guide

    • @ElectroGlobe1
      @ElectroGlobe1  3 роки тому

      If SF6 gas pressure is dropping fast. Then is it better to turn off that particular compartment before SF6 level drops below permissible limit and leads to further complications. If SF6 pressure is not dropping fast and leakage is minor, then outage of the compartment at suitable time can be planned to attend the leakage. Though it is not possible to understand the problem completely stated, as it needs to understand other conditions at your system. Hope this helps.

  • @muhammadhanif6399
    @muhammadhanif6399 Рік тому +1

    What is the reason for small glow light comes out of gis chamber?

  • @badassmoralfukka1
    @badassmoralfukka1 4 роки тому +12

    Thank you, Stephen Hawking.

  • @mohamedlakssoumi3439
    @mohamedlakssoumi3439 4 роки тому +1

    Or in CB

  • @mohamedlakssoumi3439
    @mohamedlakssoumi3439 4 роки тому

    Why we use dc 110vDc in control box isolator plz

    • @ElectroGlobe1
      @ElectroGlobe1  4 роки тому +1

      110v DC in CB is used for closing and tripping coil pick up. Whenever closing or tripping command is given to CB, DC supply goes to coil and it magnetize coil. Also it is used for contacts pick up also. Hope this answered your query.

    • @mohamedlakssoumi3439
      @mohamedlakssoumi3439 4 роки тому

      @@ElectroGlobe1 bro 110 Dc its used only in CB in substation ?and i thank you for this channel and for information i have more question but if you have a facebook or anything plz bro

    • @ElectroGlobe1
      @ElectroGlobe1  4 роки тому +1

      @@mohamedlakssoumi3439 Thank you for appreciation. As of now we are only on UA-cam. Soon we will be on other digital platforms. Same will be notified.

    • @mohamedlakssoumi3439
      @mohamedlakssoumi3439 4 роки тому

      @@ElectroGlobe1 ok bro thx a lot for you time

    • @mohamedlakssoumi3439
      @mohamedlakssoumi3439 4 роки тому

      @@ElectroGlobe1 bro can you tell me type of relay protection used in substation plz

  • @michaelschuler7397
    @michaelschuler7397 3 роки тому

    Once arch is quenched arch is aimed at crotch moving crotch quenches contacts

  • @jms019
    @jms019 3 роки тому +4

    Sorry can’t stand the sound

  • @rbwernig
    @rbwernig 2 роки тому +1

    Microfon is defect!

  • @johnsmith-tr3dh
    @johnsmith-tr3dh 2 роки тому

    5 min vid , how hard would it have been to get a person to narrate . Computer gen voice SUCKS