I have never wrote any thing on comments today writing to and liking and subscribing because u save my 18 mins by describing all reason in part on descriptiom thanks
सत नाम वाह गुरु वीर जी बहुत ही महत्वपूर्ण जानकारी देने के लिए आपका बहुत बहुत धन्यवाद । हमारे डेढ़ टन वोल्ट्स के ऐसी में 35 MFD क केपीसीतर निकला जो खराब था तो उसमें 35 का ही केपीसीतर लगाना सही है या 45 MFD का भी लगा सकते हैं ।
Thanks sir nice video 🙏 Apne bahot hi badiya 10 tip's bataye jadatar Jo log ac use karte hain unke liye khas karke jo log Naya AC laga rahe hai unke liye yeh 10 tip's janana bahot jaruri hai sir thanks 🙏
kudos to you... for the effort you put in .. i have a 1.5 ton voltas initially it had a issue of compressor just starts and stop with ina asec .. then the capacitor has been changed and it was working well. later on the same issue occured with in 10 days. then we changed the capacitor again but still the issue was persisting then the service guy suggested me that issue could be on PCB. so he took for service and said relay has been replaced then after that...same issue persists.. then he suggested that problem is in compressor and he changed that too...then the A.C started well and it was working for 1/2 an hour then we can hear a noise like electric thud inside the indoor and it trips off everything even the MCB switch for the AC and even the MCB switch which has for the AC line itself.. auto trip... once i leave it for some time .. may an hour if i switch it on again it works... i cannot come to a conclusion. please help me in this regard..
@@kritikverma1407 it's split AC..and more over the condensor and the capacitor both are in shelter only.but still it gets trip some times half an hour some times one hour..it behaves odd
Bro literally the same is happening with me and I'm so fed up it's hell and loads of money have been wasted till now and I'm not hesitant to spend any money and have actually given up I just use it for 1-2 hours continuously and shut if off for some time
@@sheldoncooper9918 at last my issue is fixed.... issue is with pcb board.. just given for service and checked all components ,including stabilizers and compressor... they are saying usually when the compressor is aged or its outlived its utility then the problem slowly arises... so please check the pcb board.
Putar good Hoya se. Outer exhaust direction must match the natural wind direction. If the direction of outer opposite to natural wind direction then it need extra effort and all hot air will again be in contact with condenser.
Thanks brother for such good information, God Bless You for that, please reply as my Hitacho Ace 1.5 tomln split ac blower speed is fluctuating and compressor not aorking ang no cooling. Kindly reply asap. Waiting for your Guidance. Thanks 😊
Excellent presentation of the video with a very good narration in simple words!👍👍👌👌 Thanks a lot for this complete technical knowledge! वाहे गुरु जी आप पर हमेशा अपनी कृपा बनाए रखें!🙏🙏
@@zahidquadri1524 Couldn't understand what the hell are you talking about? But I'm quite sure that you cannot say anything good in the comment section.
Mandeep ji, I am your follower. I have an o gen window ac. Due to fluctuation in voltage it's not starting whereas stablizer lights are on.. what could be the reason. It was working fine few days ago. Recently serviced(a month ago). Pls suggest🙏
Thanks for the knowledge, but normally all AC technicians do not do their job correctly. some deliberately keep the flange nuts on outdoor AC inlet and outlet pipes loose, so that Gas gets leaked and then they are again to be called for gas refilling. Our technician refilled the gas but even after that cooling is not proper, but he does not agree and insists that outside temperature is too high but my other AC is working very well. Problem is more with the technicians as we rely only on them.
Sir window ac hai 1 ton ka jab start karo toh 1 ya 2 gante tk best cooling deta h uske bd apne app colling band ho jati h and compressor on ni hota please reply...
Sir ji apki video achi hoti mene kai chote chote fault khud se thik kr liye apki batyi video se, But mujko ab yeh puchna cahata hu mera daikin ka ac hai normal jiska compressor band ho jata hai lekin outdoor fan chalta rehta hai, thodi der ya one hour baad jab ac on krke chalata hu to chal jata hain Kya uska capaciotor ki prblm to nahi ho skti yeah
Sir, AC ki fan speed high rakhni chahiye ya low, energy consumption kam rakhne k liye. Kisi video m bataya ki temp. low and fan speed high rakhne se energy consumption low hota h. Your advice on this will mean a lot. Thanks and wish you a very good health
@@emmvlogs mere window AC का compressor overheat ho के trip ho raha hai,मगर सुबह के टाइम ठीक चलता है, केवल दुपहर में ये problem hai। To Kya gas ke problem h
@@apcgamer2265 Look cover it with a awning protect it from Both direct sunshine and direct rain water. Water is a conductor and could become a source of a short circuit and could ruin the PCB if it gets into it.
@@praveenmalhotra159 I think it should be safe I never had such problem with my printed circuit board I've been using my ac since 5 years and it regularly gets wet on rainy days yes if you don't wanna risk it it's your choice brother
Sir split AC reinstall kiya, outdoor k valve khole to indoor se oil nikla, baad me pata chala ki suction pipe indoor unit k andar bend pe toota hua hai. lagbhag kitna oil nikla hoga. kya compressor oil ki refilling karani padegi ya koi problem nhi hogi?
Veer g whirlpool 1.5 ton split ac lgaya brand new …jst 2 month hoye use karte but abi outdoor unit chlte chlte bnd ho ja rha again and again! Bta sakte ho Kya problem hogi ??
Sir apka videos koi normal admi bhi dekhega toh woh AC tecnician aisehi banjayega...great video👍👌
I have never wrote any thing on comments today writing to and liking and subscribing because u save my 18 mins by describing all reason in part on descriptiom thanks
1 air in system
2 low gas
3 low voltage input
4 Dirty condencer coil
5 weak capacitor
6 weak compressor capacitor
7 filter drier or capillary tube
8 compressor terminal losses
9 compressor oil
10 high heat load
Wow! You have noted everything in Ten points. Very Good 👍
Rgt you are
Great
सत नाम वाह गुरु
वीर जी बहुत ही महत्वपूर्ण जानकारी देने के लिए आपका बहुत बहुत धन्यवाद । हमारे डेढ़ टन वोल्ट्स के ऐसी में 35 MFD क केपीसीतर निकला जो खराब था तो उसमें 35 का ही केपीसीतर लगाना सही है या 45 MFD का भी लगा सकते हैं ।
Bhai saab thanks ap ki madad se ham ne apna AC ki khud hi service kar li hai. Thank you very much.
Aap bahut soft spoken ho, badhiya tareeke se smjhate ho. Thank you brother
Thank you so much sir for such a detailed explanation. God bless you
Bai.ji.bahut.achhi.jankari.t.diti.hai.dhanbad..Lelewala..
Thankyou very much and take care of you and your family sir.🙏🙏
People should see this video before buying an AC. Very Good
Thanks sir nice video 🙏
Apne bahot hi badiya 10 tip's bataye jadatar Jo log ac use karte hain unke liye khas karke jo log Naya AC laga rahe hai unke liye yeh 10 tip's janana bahot jaruri hai sir thanks 🙏
Very nice Mera window AC trip ho gya tha mujhe lga k jal gya hai but aapki video dekh k Dil ko tasali mil gyi thanx
kudos to you... for the effort you put in .. i have a 1.5 ton voltas initially it had a issue of compressor just starts and stop with ina asec .. then the capacitor has been changed and it was working well. later on the same issue occured with in 10 days. then we changed the capacitor again but still the issue was persisting then the service guy suggested me that issue could be on PCB. so he took for service and said relay has been replaced then after that...same issue persists.. then he suggested that problem is in compressor and he changed that too...then the A.C started well and it was working for 1/2 an hour then we can hear a noise like electric thud inside the indoor and it trips off everything even the MCB switch for the AC and even the MCB switch which has for the AC line itself.. auto trip... once i leave it for some time .. may an hour if i switch it on again it works... i cannot come to a conclusion. please help me in this regard..
You have split or window??
If you have a split then give it a shelter to condensor which protect it from the sun rays
@@kritikverma1407 it's split AC..and more over the condensor and the capacitor both are in shelter only.but still it gets trip some times half an hour some times one hour..it behaves odd
Bro literally the same is happening with me and I'm so fed up it's hell and loads of money have been wasted till now and I'm not hesitant to spend any money and have actually given up I just use it for 1-2 hours continuously and shut if off for some time
@@sheldoncooper9918 at last my issue is fixed.... issue is with pcb board.. just given for service and checked all components ,including stabilizers and compressor... they are saying usually when the compressor is aged or its outlived its utility then the problem slowly arises... so please check the pcb board.
@@kanakasabapathy6523how old was ac
All Reperengi... Successfull...Thanks Bro....
Sir aisa lag rha ke hm school me hai very good 👍👍👍👍
Very nice video 👍 bhai on Air conditioner
Nice thanks for the nice and very detailed explanation
नमस्कार ! आपने बहुतही अच्छा समजाया हैं, आपको हमारा आशीर्वाद, अगर आप मुंबई मे रहेते हैं तो हम आपसे एसी सर्व्हिस कॉन्ट्रॅक्ट कर सकते है, धन्यवाद !
You have shared detailed information about the AC's outdoor unit problems and how to solve them. Good video.
First 6 seconds were so beautiful....
Nice explanation. It is helpfull.
Nice way of talk. Sat shriakaal.
Excellent knowledge and good presentation 👍
GOOD INFORMATION SIR JI TUSI GARAT JI
Good 👍 excellent Inphotmation
Putar good Hoya se.
Outer exhaust direction must match the natural wind direction. If the direction of outer opposite to natural wind direction then it need extra effort and all hot air will again be in contact with condenser.
Thanks brother for such good information, God Bless You for that, please reply as my Hitacho Ace 1.5 tomln split ac blower speed is fluctuating and compressor not aorking ang no cooling. Kindly reply asap. Waiting for your Guidance. Thanks 😊
Excellent presentation of the video with a very good narration in simple words!👍👍👌👌
Thanks a lot for this complete technical knowledge!
वाहे गुरु जी आप पर हमेशा अपनी कृपा बनाए रखें!🙏🙏
B Hnn jiju i ohk ink mkn n bhn j😊knj Kn
I’m I’m just pj. V I
N. Nbbm ma. K. M z. K k. Mom. M kr. I jk 😅❤x❤🎉
@@zahidquadri1524
Couldn't understand what the hell are you talking about? But I'm quite sure that you cannot say anything good in the comment section.
Good information.Nice naration.
ਭਾਜੀ you have done a great job
Excellent job
Wonderful information, bahut hi shandar kam kar rahe ho Bhai Saab app.
Thank you sir ji very easy explained.
Thanks for sharing so good thoughts and guidance regarding compressor tripping. God bless u. Rathe Rathe
Very informative vidio.thanks.
Veera thanks for the information
Sir you must be a physics teacher 👍👍👍 god bless u sir ji
Hello
Hy
Rare video which is so detailed
Thanks for cool way of advising
Assalamu Alaikum Bhai super video
Mandeep ji, I am your follower. I have an o gen window ac. Due to fluctuation in voltage it's not starting whereas stablizer lights are on.. what could be the reason. It was working fine few days ago. Recently serviced(a month ago). Pls suggest🙏
Got the reason
Good information. Thanks.
Very good and full information video.
बहुत अच्छा जी 👌🙏
very good n clear explanation
Thankyou sir ❤️
VERY GOOD GUIDELINES ❤️❤️👍
Best explanation 👌👌👏👌👌
Thanks for the knowledge, but normally all AC technicians do not do their job correctly. some deliberately keep the flange nuts on outdoor AC inlet and outlet pipes loose, so that Gas gets leaked and then they are again to be called for gas refilling. Our technician refilled the gas but even after that cooling is not proper, but he does not agree and insists that outside temperature is too high but my other AC is working very well. Problem is more with the technicians as we rely only on them.
Sir i have purchased lg enze model ac yesterday day,but outdoor fam moving anticlockwise,is it ok ?
Very good video sir
Very good information bro.
Sardar ji mistubishi 1 ton jp 13 VF model kesa h non inverter me colling ms gk km h
Great information
Very nice vishlation
Thank you brother
Great Video 😊
Vir g output 180 to 200 chldi h koi prblm ho skdi h ya ni stablizer 115 to 270 range da h cooper
Phaji koi best stabilizer bta do ..🙏🏼
WISH YOU A HAPPY AND HEALTHY WEEKEND .
Thanks
Same to you
Sir window ac hai 1 ton ka jab start karo toh 1 ya 2 gante tk best cooling deta h uske bd apne app colling band ho jati h and compressor on ni hota please reply...
Thanks a lot sir. .very informative
🙏
Good information sir jee
Good video !!!! Sir Apka shop kanha hai?
Zabardast sir g
Sir ji apki video achi hoti mene kai chote chote fault khud se thik kr liye apki batyi video se,
But mujko ab yeh puchna cahata hu mera daikin ka ac hai normal jiska compressor band ho jata hai lekin outdoor fan chalta rehta hai, thodi der ya one hour baad jab ac on krke chalata hu to chal jata hain
Kya uska capaciotor ki prblm to nahi ho skti yeah
Thanks for information
Good information
Good job sir
Best In Presentation..
Great Job..👍
Always help full
Very beautiful sir, we liked it very much.
Thank you very good thing
Vry well knowledge sir...👍
Sir Hitachi ac da outdoor unit open karke ek video comparison banao, is this powerful than Daikin?
Is it makes more noise than daikin??
Excellent!!
Very important information
Nice video sir
Sir, AC ki fan speed high rakhni chahiye ya low, energy consumption kam rakhne k liye. Kisi video m bataya ki temp. low and fan speed high rakhne se energy consumption low hota h. Your advice on this will mean a lot. Thanks and wish you a very good health
Sir ji Voltas 1.5 ton Inverter window ac 32900 ka mil raha h, kya ye ac le lena chahiye ya +-2000 mein koi or acha ac aap suggest karna chahege
Kya inverter ac bina Stablizer k b chala sakte h?
Voltas ac model no h 185V ADA
Please make a video best copper stabilizers with digital display and amp meter that showz amp
This is very helpful in inverter ac
Will try
@@emmvlogs mere window AC का compressor overheat ho के trip ho raha hai,मगर सुबह के टाइम ठीक चलता है, केवल दुपहर में ये problem hai। To Kya gas ke problem h
@@rahuliocl1234 mera night main yeh problem h
@@poojawalia8251 पूजा जी, अभी मेरा ac सही चल रहा है,अपने आप सही हो गया,2 month पहले प्रॉबलम थी,1 -2 दिन बाद अपने आप सही हो गया,
Throwing water on the condenser is a bit risky especially if the water 💧 gets into the PCB.
AC gets literally showered on rain how is it risky?
@@apcgamer2265 Look cover it with a awning protect it from Both direct sunshine and direct rain water. Water is a conductor and could become a source of a short circuit and could ruin the PCB if it gets into it.
@@praveenmalhotra159 I think it should be safe I never had such problem with my printed circuit board I've been using my ac since 5 years and it regularly gets wet on rainy days yes if you don't wanna risk it it's your choice brother
There usually is no PCB in outdoor unit
@@UnHappy646 I am talking about the window AC where the PCB board is near the compressor
ac capacitor for 1.5 ton ( outdoor split ) > can pls give specification to buy it
AWESOME VIDEO SIR
mere whirpool ac 20 din m khrab hogya compressor khrab bta rahe h pcb bi outer ki puri unit change kar vau ya yeh do part ko?
Well explained ! Thanks
Sir split AC reinstall kiya, outdoor k valve khole to indoor se oil nikla, baad me pata chala ki suction pipe indoor unit k andar bend pe toota hua hai. lagbhag kitna oil nikla hoga. kya compressor oil ki refilling karani padegi ya koi problem nhi hogi?
Sir koi problem nhi oil jada na nikla ho
Super best 🙏👍 & thanks
Veer g whirlpool 1.5 ton split ac lgaya brand new …jst 2 month hoye use karte but abi outdoor unit chlte chlte bnd ho ja rha again and again! Bta sakte ho Kya problem hogi ??
Brother same ac and same problem mein bhi face kr raa hu
Agar koi solution miley to batana
@@manavking599 bhai service centre walo ko call kiye 2 din ho gye abi tk koi aaya nahi …..bdi bekar company ka ac le liya
very nicc sir ❤
Thank uh brother 🙏🙏
1st like press by me...😀
Thanks
Sir, kya aluminum ke condenser ki jagah copper ka condenser lagwaya ja sakta hai.
Sir agar hmm inverter ac 24 pe chalate hai ...kya. Room temperature 24 ho jane ke bad compressor trip ho skta hai
Best window ac 2021 pe video bnaye please.
10 years warranty m kyaa kya cover hota hai compressor ki
Apne jo points btaye es video m compressor se related vo free of cost thik hoga ?
Suggest me a better copper stabilizer??
Candas cheap best
Hello sir mera window ac hai kya us ke upar bhar ki devar pr chaddr se cover kr sekte hai
Boht aala good
Paa ji ogernal thik ya carrier window 1.5 ton
OG
Very nice