I am a final year b.tech student . your videos helped me to pass my end semester exam just in one night. As the book explanations are too lengthy you made it simple to remember. thank you
Nice video sir, but one concern, you said that circuit bridge is in control room, but in actuality it directly connected to transmitter and transmitter connected to dcs or PLC so my question is that your theory is little bit confusing, please clear this, thanks
You can simply try if measure resistance is 138 then 138-100 =38. Then 38 divide by .385=98.7 is degree Celsius so at 38 resistance your temperature is 98.7 degree Celsius.
Main difference toh temprature measuring range ka ho hai thermistor ki range 200 degree tak hi hai high range (500 degree+ ) ke liye thermocouple ya RTD use karte hai aur 2000 ya usse vi jyada temprature ho toh pyrometer ka use karte hai measure karne mein 👍
Sir f.o ( Furness oil ) kaa temperature Measure ment k liye kounsa Rtd Lagaye ye yaha hamara 120 to 140 c temp he hamate yaha pt 100 laga he but ye barabar kaam nahi karta he so pliase replay kounsa rtd lagaye 140 c k liye????
Hi sir... mai iti student. Mera jankari itna nehi hai ... 100 mtr lenth 3 core armar cable keya laga sekta hu controler se rtd ?? Lagane ke bad resistance kitna value barhega thora jankari dete to a6a hota.
Uss wire ko dekh bro woh direct jaaker voltmeter mein jud rha hai jisse pichle waley mein jo resistance ke threw connection tha jisse extra resistance add on ho rha tha woh khatam ho jaayega jisse meter ki reading jyada exact ho jaayegi , I think now you got it 👍
I am a final year b.tech student . your videos helped me to pass my end semester exam just in one night. As the book explanations are too lengthy you made it simple to remember. thank you
I am also 😊
Guess, i'm actually you, just 5 years younger 💀
Just amazing experience
Sir! Your explanation is truly admirable
very nice sir ,very informative,u covers every doubt point , thanks a lot
Nice video keep going...
Lots of love from Nepal sir
Sir u are God for External Students. I'm requested to you Finally say How's the question is solved with systematic manner. Thanks for this video.
Range of PT100 RTD is -260°C to 850°C as per IEC 60751.
H yr
You explain practical , i request to you also explain with theories
Thank you sir for simple explanation ❤
Thanks you sir khup Chan video ahe😊😊
Nice video sir, but one concern, you said that circuit bridge is in control room, but in actuality it directly connected to transmitter and transmitter connected to dcs or PLC so my question is that your theory is little bit confusing, please clear this, thanks
bahut khoob saini sahab
Good explain.good sharing knowledge.thank you sir for making videos
Hi, I like your lecture. Thanks
14:55 summary 😊
You can simply try if measure resistance is 138 then 138-100 =38. Then 38 divide by .385=98.7 is degree Celsius so at 38 resistance your temperature is 98.7 degree Celsius.
ok
Good explainton of R.T.D
Very helpful video ... thank you
Control valve ke upper ek video banaiye sir
Sir app bohot acc pardate ho.thank yoy
Bhai achhi lgi vedio samaj bhi aaya
Nice and easy wording ...
Also easy to understand keep it up 🌹🌹
Namaskar saini sahab
1:00 save time
sar....exempal ke sathe samjaiye.....app bahut accha pathate ho.....magar exempal ke bina thoda samaj nahi ataa
Thank u sir kaffi achi vedio banai
Very informative sir ❤️
Very Good explanation
Very nice explain 🙏🙏
Very Helpful
Really informative
Nice explanation
Very helpful sir
Very nice 🙏
Good information sir
So good sir
Air luck relay pe ek video banaiye srji
Pls described optical fibre
High response k liye kon sa metal ka rtd use krna acha rhega sir
Sir, Led kaise jalti hai isko leke ek video banaiye
Superb sir....
Good
Nice sir
informative
Rtd and tharmocouple ki temperature keise nikale ek video banaye please.
Thermopile pe videos banye sir
Maza aagay guru.
RTD , thermostat , tharmo cupal, PT 100 me kya difference hai ek vedio bnaye please sir 🙏🏼🙏🏼🙏🏼
Main difference toh temprature measuring range ka ho hai thermistor ki range 200 degree tak hi hai high range (500 degree+ ) ke liye thermocouple ya RTD use karte hai aur 2000 ya usse vi jyada temprature ho toh pyrometer ka use karte hai measure karne mein 👍
Sir instrumentation ke liye aur video banaeye
Very nice sir
Thank you sir 😊👍
Nice video sir😍
gd work 😊
Very good
Please make a video on heat tracing cable
Love you sir
Aap se guzarish hai ke aap slowly slowly baat kre
Thoda relax ho kr
Itti speed me nai
Sir f.o ( Furness oil ) kaa temperature
Measure ment k liye kounsa Rtd Lagaye ye yaha hamara 120 to 140 c temp he hamate yaha pt 100 laga he but ye barabar kaam nahi karta he so pliase replay kounsa rtd lagaye 140 c k liye????
Sir physically how we understand different RTDs like Tungsten....and others
4:32 for good luck
nice video sir
sir in 3 wire rtd there will resistance of middle wire and 3rd wire also
Sir, egg incubators k li y ae kon sa controller suitable hy?
Sir ji RTD me resistance badhane pe temperature pe kya effect padta h
Ashok g aapne industry me instruments pe Kitna time work Kiya hai ?
All ok Bay best
4.32- Pehale petpuja karlunga... Phir video banata hu😁😁
How to calibrate flow transmitter in hindi
Good sir
Sir RTD mai kuch source dete hai kya
Hello sir,
Can i explain
How to convert
Volte to Degree celsius..
Sir jaisa ki kisi room ka tempreture 30 hai rtd hame output kya degi
good one sir
THANK you sir g
Hi sir Water level k leye konsa sensor use hota hai
Super sir
Very successful
Sir
liquid in metal thermometer.
Er
Murcurry kothay thake
Steel bulb , capillary tube , boredom tube
Please answer ta deben
Difference between Rtd & thermocouple. Please describe it.
Accuracy, cost aur measure speed mein fark aata hai bro , RTD sabhi parameters mein thermocouple se jyada accha hota hai 👍
Sunder
Sir ek example bataiye na
Jese 215 ohm bta rha h rtd me to usako temperature me uska man kitna aayega
Plz visit , All practical concept will clear , how to calculate RTD temperature
ua-cam.com/channels/CxZ8Oi2zXsAS1JgugGOmbQ.html
Nice video
PT 100 range is around -200° to 850°C
This is true
Thank you 😊
Sir resistance eliminate kaise hoga 3 wire me jab ki dono ki wiring ek jaisi h
Sir how to reduce hunting control valve and positioner,also I to p
Grt sir
Hi sir... mai iti student. Mera jankari itna nehi hai ... 100 mtr lenth 3 core armar cable keya laga sekta hu controler se rtd ?? Lagane ke bad resistance kitna value barhega thora jankari dete to a6a hota.
plz tell the advantages of thermistor over rtd.
Sir how to convert Rtd to thermocouple or vice versa on line...power plant question
Cantrol Valve kis Principal par kare Karta hai
RTD measure kisme karte hai sir ohm ya mv
Please mere liye mass flow meter pr ek video banaye
Sir kya hm ek hi thermocouple se do jgy pr temp dekkh sekte h
थोड़ा आराम से बोलिये सर
Hallo sir mera ye rtd wire kharab ho gaya hai aur mai jahan hoon wahan milta na hi koi desi jugaar ho to bata dijiye
Steinhart-Hart equation full details with example video
Why use 0.385 for pt100
Thank you sir
sir r1 r3 ki kya value le
How you will balance extra resistence using third wire? named as temperature compensation
Exactly
Rupendra Lanjewar
It is very helpful. Thankyou
Uss wire ko dekh bro woh direct jaaker voltmeter mein jud rha hai jisse pichle waley mein jo resistance ke threw connection tha jisse extra resistance add on ho rha tha woh khatam ho jaayega jisse meter ki reading jyada exact ho jaayegi , I think now you got it 👍
Sir RTD kitane voltage tak aati hai?