How To: Program A Hayward TriStar VS

Поділитися
Вставка
  • Опубліковано 22 гру 2024

КОМЕНТАРІ • 49

  • @mudder4660
    @mudder4660 Рік тому +1

    Pump programming all done thanks to this video. Hayward instructions were not clear on simply pressing Menu multiple times to cycle to programming/timer/speeds/diagnostic modes. Thanks.

    • @Inyopools
      @Inyopools  Рік тому +1

      Glad it helped. The written instructions are not always clear.

  • @aced3127
    @aced3127 2 роки тому

    I can save all settings except for time and day, pressing menu goes back to main after I set day and time, no confirm changes pops up and goes back to main screen with 0:00 as the time. Any idea what the issue may be. Tried cycling power, did not help.

  • @azfluffy6332
    @azfluffy6332 5 місяців тому +2

    very clear explanation - thx!

  • @hansh1856
    @hansh1856 Рік тому

    I upgraded my system with the retro fit kit to Omni Logic. I get a commutation error and nothing on the pump display. I verified I have 240 V at the pump terminals. I’m not sure if the display had been out or if it has to do with the upgrade board I installed. Should that pump display light up with power only or could it be a low voltage signal problem?

  • @eugeneward900
    @eugeneward900 9 місяців тому

    Great Video ! A big help in programming our new Hayward Pump. Thank You !

  • @cpvsgvmnt2116
    @cpvsgvmnt2116 Рік тому +2

    Why cant i just manually turn it on? I have to wait for the scheduled time?

  • @mudder4660
    @mudder4660 Рік тому +1

    Confirmed with Hayward via email that the internal programming memory lasts 3 weeks if a loss of power occurs. This will allow me to keep my old mechanical timer to stay installed, with setting its time off & on as close together as possible. Have a Tristar W3SP3202 VSP model.

  • @emtzjr
    @emtzjr 2 роки тому

    Morning Timer1 is set to 3250rpm. Evening Timer2 is set to 2700rpm. What determines the watts that will be used during the hours the pump goes on? The very few times I've looked at the watts being used when the pump is on vary from 5watts to 2499watts. There are other wattage numbers in between but I cannot recall exactly what they are. Should the watts be consistent for each timer or do they fluctuate depending on something? Thx.

    • @Inyopools
      @Inyopools  2 роки тому

      The watts will run higher when the pump is running at 3250rpm and lower when the pump is running at 2700rpm. There may be fluctuations in the wattage during Timer1 and Timer 2, but the wattage will be consistently higher when the RPMS are higher.

    • @emtzjr
      @emtzjr 2 роки тому

      @@Inyopools This past Tuesday, timer 2 was running at 2700 rpm and 2499 watts. Today, it is running at 2700 rpm and 5 watts. Is this normal for the watts to be so off? I’ll definitely look and note down the readings these next coming days to see if there’s any other wattage readings.

    • @Inyopools
      @Inyopools  2 роки тому

      If the filter is dirty, the pump will cavitate. This could cause the fluctuation in wattage.

    • @emtzjr
      @emtzjr 2 роки тому

      @@Inyopools this morning, it’s running at 3100 rpm and 5 watts

  • @guitarstar717
    @guitarstar717 3 роки тому

    My new Tri Star turns on at 34 degrees and runs at the highest speed and will not turn off after temp is over 40 degrees even after 8 hours, My Eco Star allowed more settings. How can I lower the speed setting & get it to turn off in Low- Temp on?

  • @donaldwilcox6503
    @donaldwilcox6503 Рік тому

    How would you set the speed display to off on the tristar ?

    • @Inyopools
      @Inyopools  Рік тому

      Are you asking how to turn off the pump? Or do you want to keep the pump running but turn off only the display?

  • @handymanbrian8269
    @handymanbrian8269 Рік тому

    if 240v power is stopped to pump, will it hold the last settings?

    • @Inyopools
      @Inyopools  Рік тому +1

      Variable speed motors usually have a battery back up for their timer. This allows the timer to maintain schedules and some functionality when power is not applied.

  • @emtzjr
    @emtzjr 2 роки тому +1

    How would you “turn off” timer 2 after it is programmed?

    • @Inyopools
      @Inyopools  2 роки тому +4

      You can turn off an individual timer without resetting the entire system. Go to the timers menu. Press the > key until you get to timer 2. Press the + key to edit. Change the start and stop times to be the same time (i.e. 8am to 8am). Press the > key to advance to the next timer and it should go to off.

    • @emtzjr
      @emtzjr 2 роки тому +1

      @@Inyopools Awesome. It worked. Thank you!

    • @Inyopools
      @Inyopools  2 роки тому +2

      That's great to hear! Thank you for giving us an update.

  • @pjkellogg45
    @pjkellogg45 6 місяців тому

    My Hayward Tri star 1.85 hp display panel has gone off and I can’t get it back on..brand new installed yesterday..trying to unlock and program today and it just stopped…throwing power breaker off and on did nothing..THANKS

    • @Inyopools
      @Inyopools  6 місяців тому

      Is the motor still running and following the set schedule? Or is the pump just dead?

    • @pjkellogg45
      @pjkellogg45 6 місяців тому

      @@Inyopools just dead!

    • @Inyopools
      @Inyopools  6 місяців тому

      First, I'd check the motor circuit for voltage output and continuity. I'd also check that the motor voltage switch and any dip switches are in their correct position on the motor control. If everything checks out, I'd contact the retailer from whom you purchased the motor and have them start a defective claim.
      Helpful Guides:
      Using the Proper Test Equipment to Troubleshoot Pool Motors - www.inyopools.com/blog/using-the-proper-test-equipment-to-troubleshoot-pool-motors-2/
      How to Test a Pool Pump Capacitor - www.inyopools.com/blog/test-pool-pump-capacitor/

    • @pjkellogg45
      @pjkellogg45 5 місяців тому

      @@Inyopoolsthank you! I got all the electrical stuff checked by my electrician..the store is replacing it with another new one! Great service!

  • @MSPoolsLawns
    @MSPoolsLawns Рік тому

    Is there a way to program the “quick clean” button to run longer than 1 hr?

    • @Inyopools
      @Inyopools  Рік тому

      It does not appear you can change the duration of the Quick Clean run time. Quick Clean runtime maxes out at 1 hour.

  • @kristinbowman1635
    @kristinbowman1635 4 місяці тому

    I programmed the times thanks to this video but I have 2 follow up questions:
    1. How do I reset the entire timing system? I have 5 programmed speeds but I’d like 1 or 2
    2. How do I run the pump for 24 hours for a day? I need to shock the pool and run the pump, but can’t figure out how to get it to run that long

  • @VickyMartinez-z6t
    @VickyMartinez-z6t Рік тому

    How can u change the watts

    • @Inyopools
      @Inyopools  Рік тому

      Changing the motor's RPMs will also change the power usage.

  • @debrairizarry383
    @debrairizarry383 Рік тому

    How do we set timer to run for 24 hrs?

    • @Inyopools
      @Inyopools  Рік тому

      Just as you would with any other timer setting, set which days of the week you want it to run, then set the on/off schedule to 24 hours.

  • @Empt109
    @Empt109 3 роки тому

    Video helped me program my pump so thanks.

  • @enevarez1471
    @enevarez1471 Рік тому

    My pump isn’t displaying but everything is working. Anyone know how to turn it on??

    • @Inyopools
      @Inyopools  Рік тому

      Is the pump new or has it been installed for a while?

    • @enevarez1471
      @enevarez1471 Рік тому

      @@Inyopools
      I've had it for about one year now. I just noticed that there’s no display turned on. I’m not sure if there’s a power button

  • @PabloCubarle
    @PabloCubarle 7 місяців тому

    how to turn off a program or timer. only can turn on but not off. frustrating :/

  • @martyfreeman8470
    @martyfreeman8470 2 місяці тому

    my vsp display screen is blank

    • @Inyopools
      @Inyopools  2 місяці тому

      OK, is this a new installation or an older motor? Have you verified that the motor is receiving power? Does the motor still run at its normal pump schedule?

  • @organicvids
    @organicvids 3 місяці тому

    Is there wifi?

    • @Inyopools
      @Inyopools  3 місяці тому +1

      The pump itself does not have wifi. However, it can be connected to a Hayward control system that has wifi. So if you have a Hayward control system, you can control the pump remotely.

  • @kristoferblackburn8601
    @kristoferblackburn8601 2 роки тому

    How to change the language from Spanish to English

  • @TheSpole
    @TheSpole 2 роки тому

    I’m looking to just program my pool at one set speed for 24/7 😭 I’m so confused 😐

    • @Inyopools
      @Inyopools  2 роки тому

      Once it is wired and has power, I suppose you could press one of the pre-programmed speeds and just let it run. The default speeds are listed below. Preset Speed settings can be quickly updated using the + and - arrow buttons to change the speed and then pressing the > button to save the new speed setting if desired.
      Default Speeds:
      Speed 1: 1150 rpm
      Speed 2: 1725 rpm
      Speed 3: 2300 rpm
      Speed 4: 2875 rpm

  • @bertc5970
    @bertc5970 Рік тому +1

    I would never install Hayward. Pentair are so way easier to program

  • @DODGER3213
    @DODGER3213 3 роки тому +1

    This pump is complete garbage