  • @fidelenglish6914
    @fidelenglish6914 7 років тому +5

    I really like this video because it's clear concise and to the point. No nonsense, no fluff, and for that, you get a thumbs up from me. Well done!

  • @bolinggoy
    @bolinggoy 7 років тому +5

    good, slow, methodical teaching. easy to understand. thanks very much

  • @FrankMerendaBadShot
    @FrankMerendaBadShot 5 років тому +3

    THANK YOU! Finally, transformers explained in a straight forward manner!

  • @noradhamjamarusly8174
    @noradhamjamarusly8174 6 років тому +2

    I like your tutorial video and all your feedback comments.easy to understand.its really helpfull for me and many people.keep it up and thanks a lot sir.

  • @lsk2141a
    @lsk2141a 7 років тому +2

    Thanks for the video. The explanation and illustration is very clear and concise.

  • @kaweeahmadalvi2254
    @kaweeahmadalvi2254 7 років тому +10

    Good Information for non-professional people like me...

  • @johndro3014
    @johndro3014 5 років тому +2

    I LIKE YOUR STYLE, "We have the option of doing this two ways, the right way and the WRONG way.

    • @johndro3014
      @johndro3014 5 років тому

      I had to subscribe a little later into the video.

  • @cndjx
    @cndjx 4 роки тому +2

    Excellent presentation, and well done! Thank you!

  • @Adamjrfamily
    @Adamjrfamily 6 років тому +2

    u are great sir.like your tutorial.its easy to understand.

  • @ashokm4845
    @ashokm4845 Рік тому

    Thank you. Very nicely explained. You are a good man!

  • @playstorepj2788
    @playstorepj2788 6 років тому +2

    thanks a bunch for the video and explanation, you are awesome!!!!!

  • @leehotspur9679
    @leehotspur9679 5 років тому +1

    Thank you for sharing Well explained & professional

  • @jonthephilanthropist
    @jonthephilanthropist 6 років тому +2

    Very well explained. Thanks, well done

  • @MOTHERSKYWOOD
    @MOTHERSKYWOOD 4 роки тому

    Thanks for the good info! I'm building a project desoldering iron and Hopefully this is a good step in the right direction.

  • @amichief1437
    @amichief1437 7 років тому

    Thanks John, Never to old to learn. I now know a bit more in this regard.

  • @bentumbentum
    @bentumbentum 8 років тому +1

    I woud do measurement all wire of transformer againt case of transformer...isulation...
    Best video i see this about topic...thank you very much...

    • @1929fordhotrod
      @1929fordhotrod  8 років тому

      You can measure the resistance from each transformer wire to the case or core of the transformer. You should get an infinite resistance measurement if all is okay.

  • @bassamjafar7526
    @bassamjafar7526 5 років тому +1

    very good information .. I learned a lot

  • @555millie
    @555millie 6 років тому +1

    Thank you, the turns ratio formula at about minute 2.40 will help me determine the size fuse I need for a (120V to) 14 volt 1.1 amp transformer for a little lamp I am trying to fix.

  • @md.khaledhossain1472
    @md.khaledhossain1472 8 років тому +3

    Thanks for such a great video. you are doing really good. keep uploading:-)

  • @labis6466
    @labis6466 Рік тому

    Thank you for sharing Sir, very clear!

  • @johnalastairstewartalastai7817
    @johnalastairstewartalastai7817 8 років тому +1

    Very interesting and easy to follow, thank you. 2016

  • @pietypereira8239
    @pietypereira8239 4 роки тому

    Thank you very much. Greatly explained.

  • @gweliver
    @gweliver 7 років тому

    Very informative, I have some unmarked transformer I need to measure and label for future use. Thank you!

  • @sido2335
    @sido2335 7 років тому

    Excellent video and well explained. Thank you

  • @shuaibmohammad5039
    @shuaibmohammad5039 8 років тому +2

    great video

  • @Empty7775
    @Empty7775 Рік тому

    I have a transformer in my air handler with 240v input but has a 31,15v output under load. It’s supposed to be 24v. Would this or could this cause my 5a fuse to blow? It’s basically 7.15v too high.

  • @rmarsh9997
    @rmarsh9997 7 років тому

    goes to show i learn something new every day.thank you very much .)0 ohms = a short in the transformer.That i did not realize.

  • @ARCSTREAMS
    @ARCSTREAMS 3 роки тому

    if the trans is rated for 2amps the fuse also needs to be 2amps? i think i used a 4amp fuse instead, also it says 12 volt 2amp for the outer wires but there is a yellow/green wire in between them ,would that be for 6v and 4 amps instead? it basically says " grn-grn/yel-grn:12vct 2a" does this mean any connection will give 12 volts or is this still a center tap wire?

  • @westbay5858
    @westbay5858 3 роки тому

    On the Hammond 25 volt, I want the full 25v so what so I do with the Green/Yellow striped wire... just cut it off ? Thanks

  • @turbo3089
    @turbo3089 5 років тому +1

    Where can someone either salvage them selves or buy a stepdown transformer to go from 120 volts down to anything between 12.5- 14 volts

  • @7125Mhz
    @7125Mhz 5 років тому +1

    Well done.

  • @Munzer1977
    @Munzer1977 7 років тому +1

    i bought a Weller soldering station from Amazon that uses a 110v input but i live in UAE where the mains power supply is 230v, any idea how to work it without damaging it..!! jazakom Allah

  • @nerdysophie
    @nerdysophie 6 років тому

    *Did you know?*
    Tape can be hazardous to hold down cords!
    1: If a fault occurred and it heated up the copper/metal/iron wire or the plastic coating of the wire, it can melt the tape because of its paper material, however, it does not light on fire and turn in to ash.
    2: This might sound funny and it is a hose-like situation. Tape has a great performance holding down it’s target. Just like a hose, it can cause a voltage clog.
    To test, you will need 2 ---.---- digit voltage readers on the left of the center and the right of the center, wire (not bare, or without plastic coating it), and tape. Tape the center area of the wire like it is at 9:56. Then, hold 2 readers on each side of the center. I had 0.06 volts travelling through the wire. Again, like a hose, the tape acts like a foot on a hose, so it clogs a little of the voltage. Start: Left: 0.06kV; Right: 0.04kV (See?). A bit in: Left: 0.11kV, Right: 0.00kV. Do the experiment yourself, but I used a bit tinier wire to test it.

  • @annarusso1135
    @annarusso1135 6 років тому +1

    very well done.

  • @thespiritof76..
    @thespiritof76.. 3 роки тому

    But wouldn’t the fuse protect your ❤️ from taking too much amperage acrosst it?
    And btw, you have many plastic power apparatus with bolt in transformers where your at? Can’t say I ever saw one here..... 😆.
    I enjoyed your video! Just heckling.. 👍🏼&subbed

  • @ChrisKordish
    @ChrisKordish 4 роки тому

    very useful ! thanks john

  • @RaptorMachineToolCo
    @RaptorMachineToolCo 4 роки тому

    clear and consice thank you .. how should you determine fuse size ty joe

  • @pistolpete131
    @pistolpete131 4 роки тому

    Just wondering what size fuse you should use to protect the Transformer

  • @1990pommie
    @1990pommie 6 років тому

    if viewer has the electrical gadgets you mentoin . HIGHLY UNLIKELY they would need this video.

  • @kevinanderson9243
    @kevinanderson9243 6 років тому

    I have several transformers that I have picked up over the years.Most are from microwave ovens but a few are smaller or larger and the sources are long forgotten. The other night I decided to test them to see what the output voltages are and even though they may say 120v and 60hz when I plug them in using an old cord and an outlet on my work bench, they pop my work bench breaker! They may have anywhere from 2-6 wires coming off the secondary, none touching, and only 2 wires on the primary, but when I plug it in POP ! Any ideas? Thx

  • @kaetamine
    @kaetamine 6 років тому +1

    Was the secondary winding's resistance lower due to wire gauge, or due to shorter total length of conductor in that winding?

    • @1929fordhotrod
      @1929fordhotrod  6 років тому

      For the step down transformers use in this video the secondary winding had a heavier wire used in the winding.

  • @surenbono6063
    @surenbono6063 6 років тому

    ..but what would happen if i reverse the input to output..or power through the secondary..would it be a step up...is it ok to do that...fused on the input.. of course

  • @vinmansucc2698
    @vinmansucc2698 3 роки тому

    Very good

  • @ahemednor5201
    @ahemednor5201 4 роки тому

    good and perfect

  • @MitkoGorgiev
    @MitkoGorgiev 8 років тому

    I have read that by step-down transformers the voltage goes down and the current goes up. Why is by these transformers the current so small (0,2 A; 0,5 A)? What are they used for? What does depend on, whether the maximal current is 0,2 A or 2 A? On the size of the transformer? More wire on both sides for more amps? Thanks for the interesting video.

    • @1929fordhotrod
      @1929fordhotrod  8 років тому +1

      +Stephan1098
      It all depends on the power rating or volt amps (VA) of the transformers. The transformers I used in the video are all rectifying transformers used for DC power supplies.
      Here is a simplified explanation.
      The turns ratio (a) = primary voltage (Vp) / secondary voltage (Vs) = secondary current (Is) / primary current (Ip).
      The volt amp (VA) rating = Vp x Ip = Vs x Is (assuming no loss).

    • @narayandhakal6581
      @narayandhakal6581 7 років тому

      Stephan1098 I guess the bigger size is due to the use of thick wire to reduce resistance or increase current
      sir how would u know Ip ?
      Can I assume 5amps as 5 amp 230 volts is supplied to house? or it depends on load so as to maintain required current for the load?

    • @1929fordhotrod
      @1929fordhotrod  7 років тому +1

      Yes, the bigger the wire the less resistance resulting in a bigger transformer.
      If you have a 5 amp transformer this would be the maximum current the transformer can handle on the winding the 5 amps marking was taken from. The load that is attached to the secondary winding decides (over simplified) the current flow.

  • @joerandom756
    @joerandom756 2 роки тому

    What is the cy? You said it was 60 cys but what is cycles in a transformer? thanks.

    • @ashokm4845
      @ashokm4845 Рік тому

      Cycels here means the frequency of the input power., which in US is 60 cycles or Hz and in Europe is 50. Hope this helps.

  • @tobedeleted857
    @tobedeleted857 7 років тому

    Very well explained sir. Transformer in my speaker got burnt may be due to high voltage. Replaced it with the help of your video and attached a fuse as well to it. Thank you.
    I have a query. The transformer input voltage is 230V (India) and output is 12V-0V-12V / 1 Amp. What should be reading for fuse.? As of now, the fuse which I have inserted has 3A/250V written on it. Any suggestions.? I may keep the speakers till you recommend me the fuse.

    • @1929fordhotrod
      @1929fordhotrod  7 років тому +2

      3A is too big. Your turns ratio will be 230/24 which is approximately 10. If the secondary is rated at 1 amp then you should use a 0.1 amp fuse.

    • @playstorepj2788
      @playstorepj2788 6 років тому

      i too have the exact same step down transformer!!!. i have a question "i intend to use 2 fuses one on each side i.e, on primary side as well as on the secondary side" any advice on what fuse should i use on the secondary side and how to calculate it??

  • @jamesrockford5145
    @jamesrockford5145 6 років тому

    good info.

  • @balgill6443
    @balgill6443 8 років тому

    hi if a read open on primary wires do I have a bad transformer I'm not getting any reading on ohm setting I do get 1.5 ohms on secondary wires

    • @1929fordhotrod
      @1929fordhotrod  8 років тому

      Sounds like the primary winding is defective. The wires used to connect to the power source are soldered to the actual winding wire. Sometimes these wires become disconnected. Since the transformer is not working, carefully cut away the paper protecting the winding and see if you can find the connections.

    • @DayClanTribe
      @DayClanTribe 6 років тому

      Most I find have a thermal fuse under the wrap pressed against the windings that has burned out. You can replace or bypass it to make it work again. I recently did a bath fan motor but damn those wires were so small I could barely solder them.

  • @anthony4312
    @anthony4312 4 роки тому

    good.

  • @ozansaracoglu3004
    @ozansaracoglu3004 8 років тому

    thanks but still got questions unanswered. when you connect the primary to power arent you causing a short circuit? 110v/15 ohm= about 8A of current flow whichis veryhigh. what am I missing here?

    • @1929fordhotrod
      @1929fordhotrod  8 років тому

      This would be true in a resistive circuit but the transformer also has inductance that complicates things. Remember the load in the secondary circuit controls what happens in the primary side. No load, no current in the primary circuit under ideal and loss less transformer.

    • @insylem
      @insylem 7 років тому

      Ozan Saracoglu Inductive reactance. Z. Impedence

  • @MrBrymstond
    @MrBrymstond 6 років тому

    1929fordhotrod+ What size fuse should we use for this setup so we can gauge on up and down?

    • @1929fordhotrod
      @1929fordhotrod  6 років тому

      Fuse size depends on the VA rating of the transformer.

  • @mrmoon7484
    @mrmoon7484 8 років тому

    First transformer is 12 volt, and the fourth (big) transformer is 24 volt. so the first transformer's size is almost half than the fourth 2 amp 24 volt transformer.

    • @1929fordhotrod
      @1929fordhotrod  8 років тому

      +Moon Mamun - All transformers used in the video where 24v center tapped transformers.

    • @mrmoon7484
      @mrmoon7484 7 років тому +1

      12 volt ua-cam.com/video/bvrO7g7BnIA/v-deo.html

  • @kalyanr2457
    @kalyanr2457 7 років тому +1

    Gud

  • @Bluescobra
    @Bluescobra 8 років тому

    Hello, thank you very much for your video, it was very helpfull !
    Where can I get such multimeter probes ? They seem handy with their retractable "hook".

    • @1929fordhotrod
      @1929fordhotrod  8 років тому

      +Bluescobra - The ones I was using in the video came with the Fluke digital multimeter. You should be able to purchase them at any electronic supplier selling electronic test equipment.

    • @Bluescobra
      @Bluescobra 8 років тому

      +1929fordhotrod
      Thank you!

  • @peterfrancis3865
    @peterfrancis3865 4 роки тому

    Thanx

  • @BigAL-x7f
    @BigAL-x7f 7 років тому

    is bad that if the resistances between the CT to a secondary coil and between one secondary coil to another is the same?
    your readings from a secondary coil to CT is aprox half that of one secondary coil to another.

    • @1929fordhotrod
      @1929fordhotrod  7 років тому

      Depending on the quality of your multimeter and the wire gauge of the transformer you should measure approximately the same from the CT to each end of the secondary winding or 1/2 of the total winding resistance.

  • @shishpalnegi2413
    @shishpalnegi2413 7 років тому

    i have purchased 12-0-12 3 amp transformer when i check this give output me 6 amp.
    i have 100 watt audio board which required 12-0-12 3 amp pl hekp

  • @thavamunisha1880
    @thavamunisha1880 8 років тому

    if my input voltage change will my output voltage change at 12v transformer

    • @1929fordhotrod
      @1929fordhotrod  8 років тому

      Yes, if the input voltage changes the secondary voltage will also change. It is proportional to the transformer turns ratio.

    • @thavamunisha1880
      @thavamunisha1880 8 років тому

      ok thank you sir

  • @niyonrezwan2190
    @niyonrezwan2190 7 років тому

    How can I step up 0.3 V to 1 v AC voltage? using transformer

    • @practicallab
      @practicallab 4 роки тому

      we use step up transformer to convert the voltage and after dc we use zenor diode or voltage regulator variable

  • @narayandhakal6581
    @narayandhakal6581 7 років тому +3

    sir how can we determine the rating of transformer or output current of it

    • @1929fordhotrod
      @1929fordhotrod  7 років тому +1

      Normally the current rating or VA rating will be on the transformer. If it is not marked hopefully there is a part number you can Google to find the information. If none of this information is available it is extremely difficult to determine the power rating of the transformer.

  • @ChiTownTino
    @ChiTownTino 5 років тому

    Lol correct way or incorrect way! I hope that eas a shot @ anyone who dislikes your vids!

  • @stevencooley7193
    @stevencooley7193 7 років тому

    what would each of the secondary winding leads read if put to ground?

    • @1929fordhotrod
      @1929fordhotrod  7 років тому

      You should have an infinite reading. None of the transformer wires should have a path to ground.

    • @stevencooley7193
      @stevencooley7193 7 років тому

      sorry I meant what voltage (480v prim/ 120v sec side) would I have off the secondary leads to ground

    • @1929fordhotrod
      @1929fordhotrod  7 років тому +1

      It would be the same as before. No connections of the transformer should have a path to ground therefore an infinite resistance

  • @ARCSTREAMS
    @ARCSTREAMS 6 років тому +1

    sir are you there to reply to some questions?

    • @1929fordhotrod
      @1929fordhotrod  5 років тому

      Yes, I am on the computer more at this time of the year.

    • @ARCSTREAMS
      @ARCSTREAMS 5 років тому

      it's been a long while and i dont remember all the q's i had but here are a couple for now,,
      1)if i have a 12vdc 2amp trans for the outer wires on the output does that mean if i use the center tap instead i would get 6v at 4amp?
      2)also what kind of fuse should i be using for this trans,the 2 amp or the 4 amp? does it depend on what wires i want to be using?

    • @1929fordhotrod
      @1929fordhotrod  5 років тому

      The secondary winding is designed in your case only to draw a maximum of 2A, The fuse should be place in the primary winding to properly protect the transformer

    • @ARCSTREAMS
      @ARCSTREAMS 5 років тому

      as i said it has a center tap,not sure you answered me clearly here,,if you can go over the numbered questions again and answer them,,thank you

  • @ARCSTREAMS
    @ARCSTREAMS 3 роки тому

    i think for safety ppl will plan on removing the power before they remove the fuse anyways

  • @atheera349
    @atheera349 7 років тому

    How to test a step down transformers maximum output current?

    • @1929fordhotrod
      @1929fordhotrod  7 років тому

      Maximum current specifications are given by the manufacture of the transformer and cannot be tested.

    • @hamood1234fool
      @hamood1234fool 5 років тому

      @@1929fordhotrod what happens if I attach a 1ohm resistor to the secondry coil at 24V? Will 24Amp flow through it or it will get limited?

  • @winston_vanderbilt_ll
    @winston_vanderbilt_ll 6 років тому +1

    Forget AC. Please explain DC to DC trnsformers.

    • @tf3confirmedbuthv54
      @tf3confirmedbuthv54 5 років тому

      Winston Vanderbuilt II transformers only exist in AC to AC, if you want to make it DC to DC, you’ll need to make 2 circuits. An DC to AC generator. And a AC to DC rectifier.

    • @FrankMerendaBadShot
      @FrankMerendaBadShot 5 років тому

      if I understand them correctly the basic stuff is the same, except for polarity. and measuring settings on your multimeter.

  • @ujjwalkmenon
    @ujjwalkmenon 7 років тому

    what is the fuse rating used sir?

    • @1929fordhotrod
      @1929fordhotrod  7 років тому +1

      Vp/Vs=Is/Ip is the relationship used. Therefore 115v/25v=0.3a/Ip Ip=0.065a (assuming no losses). The secondary maximum current was identified as 0.3 amps, then the maximum primary current or fuse size will be 0.065 amps, again assuming no losses in the transformer.

    • @ujjwalkmenon
      @ujjwalkmenon 7 років тому

      OK thank you sir

    • @pedrorodriguez2914
      @pedrorodriguez2914 7 років тому

      I have a new transformer and 24v is 0 output this is iN HVAC

    • @1929fordhotrod
      @1929fordhotrod  7 років тому

      Make sure your meter is set to measure DC volts first. If the meter reads 0v on the AC voltage function then the transformer is faulty. Another thing you can check is to make sure the transformer has an input voltage.

  • @SunderwolfIM
    @SunderwolfIM 7 років тому

    excuse me sir i have a transformer (step-down) from 220v to 12 volt its output rating is 12v 2 amps i have 3 output wires 12v-GND-12v can i get a 24v from this transformer by any means?

    • @1929fordhotrod
      @1929fordhotrod  7 років тому +1

      Sounds like the secondary winding has a center tap. One of the wires on the secondary side should have a different colour and the other two will be the same. With power applied to the transformer and using your AC voltmeter, connect one lead of the meter to the odd coloured secondary wire and measure the voltage from this point to each of the other wires, it will be the same. Then measure the voltage across the two wires that have the same colour, it will be twice as much. Now the voltage measurement will be higher than the rated voltage on the transformer as you will be measuring a no-load voltage. Depending on the size of the transformer and where it is made you should measure a no-load voltage across the entire secondary winding somewhere around 26-28vac. The labeling you described, 12v-gnd-12v is a common method used for center tapped transformers with 24v across the entire secondary winding. Good luck.

    • @SunderwolfIM
      @SunderwolfIM 7 років тому

      someone told me if i connected the two 12v lines together to get 12v with 4 amps the transformer will burn and it is wrong to do this is this right or wrong and how to get a 24 volt terminal and a ground terminal from this transformer to be able to rectify them to a dc and build my circuit
      i know that if i measured the two 12v wires with a multimeter it will give me a 24 v but none of them is a GND both of them is 12v but to rectify this i need a GND terminal as i know. i don't know if i can rectify a two 12v terminals. i am new to transformers this will explain many things to me.
      and thank you anyway sir

    • @1929fordhotrod
      @1929fordhotrod  7 років тому +1

      Do not parallel the secondary wires. This will not work.
      The center tap on the secondary becomes a reference point or circuit ground. Circuit ground is not the same as earth ground.

    • @SunderwolfIM
      @SunderwolfIM 7 років тому

      you mean i can rectify both 12v wires and the circuit will choose one to be a GND and then have my 24v rectified as 24v dc is this mean i will not need to use the GND wire on the transformer

    • @1929fordhotrod
      @1929fordhotrod  7 років тому +1

      Check out the links below for rectifier circuits
      www.tpub.com/neets/book7/0254.GIF
      www.interfacebus.com/diode-bridge-split-supply.png

  • @zafaradil3548
    @zafaradil3548 6 років тому

    Well,OFFSHORE mean Chines ? am i right, sir?????????

  • @fredbloggs2417
    @fredbloggs2417 6 років тому

    can you explain what your talking about were not all experts

    • @FrankMerendaBadShot
      @FrankMerendaBadShot 5 років тому

      he *was* explaining it. If you don't understand this there are some other great tutorials on electronics basics that you might want to check out. I just started learning about this stuff a few months ago and that's where I started.