Normal Fridge Converted To Inverter Refrigerator Step By Step
Вставка
- Опубліковано 16 жов 2024
- If you want to make your refrigerator more energy-efficient and save money on electricity bills, converting your normal fridge to an inverter refrigerator can be a great solution. In this step-by-step guide, we'll show you how to do it. First, you'll need to gather supplies, including an inverter kit, a multimeter, a soldering iron, and an electrical wire. Then, you'll need to open up your fridge and locate the compressor. Once you've found it, disconnect the wires and remove the old relay.
Next, you must install the inverter kit following the manufacturer's instructions. This will involve connecting the wires and soldering them in place. You'll also need to test the inverter with a multimeter to ensure it works properly. Once the inverter is installed, connect it to the compressor using the electrical wire. Finally, you'll need to close up your fridge and test it to ensure it's running smoothly.
In this video, we'll provide a detailed, step-by-step guide to help you convert your normal fridge to an inverter refrigerator. We'll also provide tips and tricks to help you make the process as easy and efficient as possible. So if you're ready to save money on your electricity bills, check out this video and learn how to convert your fridge today!
💡 Join Us On Patreon 👉 bit.ly/3vMga6S
💡 Subscribe To Get All FREE Videos 👉 bit.ly/3MMozxd
_____________________________________________________________
💡 Subscribe to Forever Tech Shorts Channel 👉 bit.ly/3gL5vQz
💡 Subscribe to the English Channel 👉 bit.ly/3pzBLvh
Social Media Links
💡 Facebook 👉 bit.ly/3hTPHvY
💡 Instagram 👉 bit.ly/3oJcwDm
💡 Twitter 👉 bit.ly/3atkbRl
****************************************************************************************************
For Business Inquiries and Promotions, Please Contact Us On Email: robin.nadeem@gmail.com
****************************************************************************************************
#Forevertech #fridge #refrigerator #inverter #compressor #diy #electric #convert
I spend a lot of my time on UA-cam. It is a precious video. Thank you for the time and efforts.
That is why I Pinned 📍 Your Precious 💞 Comment Sir😇
Awesome video abi maine dekhi puri video wohe maine socha apki video ho aur complete information na ho aesa to ho nae skta.
Over all ap ke effort bht ziada ha is kaam me salute u sir
Bhai, dubara dekhrahadha,wow detailed explanation Bhai,app very best,pura padayikarke,kam kar rahe hai 🎉❤😊
Buhat Achi explanation about magher sir,gi neya banda yah kam nahi kar sekta hai ap jesye ki bat aur hai.v.nice.
G bilkul is kam kaye liye experience chahiye
Very very very very nice video sir thanks God bless you ❤❤❤❤❤❤❤❤😊😊😊😊😊😊
Most welcome
Konsa inverter best hi r600 gas wala ya inverter r134a gas wala
thanks for very useful Video's. best bldc compressor konsa he sir plz name ya company name btane ki krpa kre.
Very good video very nice explanation keep up good work
sir cooling ice jamane ke leye best konsa inverter hi r600a gas wala ya r134a gas wala and light amp dono inverter same lete hein
Good information 👍🌹👍🌹
AoA. Boht aala.
Mujhe Karachi ma apne fridge ko DC inverter karana hay, plz koi tecnician recommend karein Karachi ma
Long video but good explained.
Thanks brother
Very very nice sir zabar dast salute to you real knowledge you have Allah bless you
Thanks sir very good information. God bless u sirji. If it possible u tell me lg refrigerator single door direct cool i have which model recommend to inverter compressor and dc drive for running. Please.
Send me the details of the compressor installed in it
MA45LCJG compressor model LG INTELOCOOL Single door direct cool.
jis thre se gas nikali global warming badne me full contribution hai aap ka🎉
پR600a refrigerant, also known as isobutane, has zero ozone depletion potential (ODP) and a low global warming potential (GWP) of 3-4. This makes it an eco-friendly alternative to more harmful hydrofluorocarbons (HFCs) like R12 and R134a.
اپ بھت اچھے ویڈیوز بناتے ھو
Bohat awlawww !!! Bhai . Salute to you .
Thanks
Or is mey kitna kharcha ata hey convert kerney ney or ye kitni bijli consume kerta hey
Great video Bhai. I watched full video and converted my fridge to inverter. Problem mujhy ya arhi Hy k Isky compressor ki speed fixed hi rehti Hy full speed mein. Iski speed Kam nahi hoti jesy company ki new fridge krti Hy. Iski speed full hi rehti Hy cooling full kr k bi. Kya koi method nahi iski speed Kam hojay cooling full hony k Baad? Kindly Bhai reply me if you can.
I think it needs a card to regulate the compressor speed otherwise it will run on one speed
Good video g ❤️ 👌 👏 👍 ❤❤❤❤❤🎉🎉🎉🎉🎉😊
Fan add krna chahty hn inverter fridge k sath. Aur jb compressor on ho phir fan chaly kindly aisi video bhi bana dan.
بھائی کیا آپ بتایں گے کے Non-Ferost فريج پے یہ R600 کمپریسر اسی طرح انسٹال ہوسکتا ہے ؟؟؟
Os par jald hi video, bnani haii
سلام و علیکم.. سر 5.7 کا عام والا کمپریسر کی جگہ پر انورٹر کمپریسر کون سے نمبر کا لگے گا. مہربانی کر کے آپ انورٹر کمپریسر کی hp پاور بتا دیں.. فیاض لاھور سے
Maine aek fridge main R600 compressor install kea woh b 0.5 ampere p chalta hai 0.7 sy start lekr aur woh non inverter tha
Thanks for the info
R600 ka compressor Kam ampere lyta hai. Inverter wagra sirf bakwas hai...
Only compressor changed ?
No PCB & wiring alteration required ?
Does it working properly ?
How much will it cost for 350 lit net volume double door refrigerator? R134 A se kaunsa gas bhi change karna padega?
Sir need your help in making inverter ac into hybrid solar AC
I appreciate if you invent some circuit using your precious knowledge
Please read and answer so that we can make our normal inverter ac into hybrid solar ac
Inverter air conditioner nowadays are running smoothly on solar power provided their outdoor and indoor fan is also dc, as some brands install ac induction fan in outdoor unit and make it useless,
In panasonic 5 star inverter ac compressor indoor fan outdoor fan swing motor all are dc and 6*550 solar panels run inverter ac whole day 9 pm to 3 pm
But in cloudy days there may be some fluctuations
To address this Amp fluctuation issue a bridge rectifier circuit can be used in air conditioner plug box on the one end of circuit we will give 220 v ac current and on another end of circuit 220v rectified dc will be produced by bridge rectifier with +v and -v polarity now connect +v of solar panel to + of bridge rectifier and -v of solar panel to -v of bridge rectifier, feedback current can be protected using diods so that solar current not go in ac line and ac rectified dc current dont go back into dc solar line diods should be connected before connecting + + and - - together will do this job, for this we need 6 panels of 550 watts and total voltage should be a little higher than grid supply
6 panels will give around 280 volt dc current while grid usually provides 250 volts
now after using this bridge rectifier air conditioner will draw current from solar panel if sufficient ampere not available in solar supply it will take remaining amps from grid we are not touching anything inside air conditioner, this circuit will make our air conditioner an ongrid or hybrid air conditioner which will primarily run on solar power if solar power is available if solar power is not sufficient it will take power from grid no separate connection needed in night time and in case of grid outage and sun availability air conditioner will keep running till sufficient power is generated through solar panels
Point to be noted 👉
in above post I used term 220v rectified dc for easier understanding but in reality 220v ac rectified gives peak voltage around 311 volt dc hence to counter this situation and maintain voltage compatibility easiest way to use a 220v to 110v converter on ac current line then do the bridge rectification and we will get around 155 voltage dc best voltage for our system
now 4x550watt solar panels will produce around 200 to 190 volt dc bridge rectifier will produce 155 v dc now solar panels output and bridge rectifier output to be connected in parallel with diods protection since device will draw current from high voltage source first it will run on solar panel if solar panel voltage drops or current drops it will take remaining power from bridge rectifier,
in the morning time solar panel will provide less amps and and our system will take remaining required amps from bridge rectifier this hybrid system will prevent fluctuations throughout the day and utilise solar+grid in day time and only grid in night time
السلام علیکم ماشاءاللّٰه
Very nice👍👌
Thanks a lot
My compressor is 300 watts. 1.5A. PEL company. Not invertor. I'm happy with it.
From Pakistan 🇵🇰 ♥.
اسلام علیکم ورحمتہ الله
Bhai main islamabad say hon
Mery pass national NOFROST fridge hai kya inverter ban sakta hai
Aur is ka expense kya aye ga
Ban Sakta hai
ماشاءاللہ آپ کا کام بہت اچھا ہے لیکن اس سے آسان ٹکنیک سوچیں کیا ہو سکتی ہے
sir g inverter bnane ke liye kitni cost ati h?
kindly advise compressor and module sell together, price pls
I don't know what is the price of now, you should visit market to get the price, yes circuit and the compressor you will get together
@@ForeverTechHindi 👍
Good bro video plese videi bny sasty ma compreser lkasy repair ho skta upr syy leek hai hunra compreser
Ok
Salam. Kia aik normal fridge ka just compressor upgrade krny se fridge normal kaam nai kry ga? Ya wiring lazmi change honi hoti ha.?
Fridge mai compressor hi tu hota jis sai cooling hoti fridge mai, ap samjh laye compressor dil hai fridge ka. Aur inverter compressor laganye sai consumption kam kare ga fridge. Because normal compressor jo hain, jab woh start hote, tu 8 amperes ka jhatka laite jo mai already check kiya hai. Ar aisa din mai kafi bar hota depending ap kitni bar fridge ka darwaza kholte aur band krte. Aur yahi par meter units ziuada lai laite. normaly hamye feel nahi hota, jab bil ata tab jaib sai paise jate tab chalta pata. inverter compressor yah jhtka nahi leta start hote waqt aur yahi par save hota, second overall consumption bhi kam hoti. Proper wiring kaye bagair tu nahi chale ga fridge.
@@ForeverTechHindi apki video dekhny k bad main yaha local mechanic ko pocha to wo kehta wiring ko hum nai cherty, just compressor purana utar k unhi wires k sath inverter compressor lga den gy to apki fridge normal kam kry gi or inverter ban jaye gi.
bahi mery pass inverter pel ki fregi hai is ka amper.1.6 hai
kame nahi hoty hai
lakin loling krny k bd trip theek hoti hai
Assalamoalaikum sir baki to sb thk hai lkn hm speed kasie control krengy inverter compressor ke thermostat sy temperature k mutabik??
Sub Kuch Same hie kam kare ga
Aur compressor automatically speed control karega, osme jo control board laga huwa hai,
@@ForeverTechHindi acha
@@ForeverTechHindiNo sir, thermostat sirf ON/OFF hay. Speed control nahin hogi. Speed control kay liye Thermister sensor lagana ho ga.
Sory sir slaynder py writing waly bhol gy hongy ap to technician hn slayndr koi bhe gas ka ho ulta karny sy liqued he jata h baki ap bather janty hn gy plz ans?
Good job 👍
Behtareen Bhai
Salam bhi ap ney inverter test nahe kya wiring k bad
Aap relays ko terminal box main mount karnay k liye din rail use karen aur relay ki base maket main available hay you should use them for better connection and prolonged problem free solution. And good job keep it up
Ok thanks
Aap kis city se hain if you are from Lahore tu main kabhi aap ki workshop visit karna chahon ga.🙂
Mai Lahore sai nahi Peshawar sai hun
@@ForeverTechHindi visit kar chuka hon Sir aap ka shehar per tab aap ka subscriber nahi tha kabhi moqa mila tu InshaAllah zaror mulaqat ho gi.
@@AliPasha200 thanks for your nice idea
U are the superstar ❤
Where can I buy the compressor
Fridge me r600 a or R134 a ka discharge temperature kitne hona best hai sir ji???
Asalam o Alykom sir ma bhi peshawar sy hon.agar inverter Ac ka PC kit thik karwana ho to ap sy kysy raabta kary plz reply
Contact on facebook or insta
@@ForeverTechHindi
Very nice sir wair is your work shope
Very good, professional 😊
Thank you! 😃
..if only the gases were recovered..😢
Sir कंप्रेसर बदलने के बाद फ्रिज की लाइफ कम होती है या फिर वही चलता है
Asalamoalikum sir compressor k size k bare me vedio banae fridge ki body me kis size ka compressor Lage ga please
Soon
Uuuuuuuuu
Great video. Please make video on converting R-22 AC or fridge to R-290 (propane).
No need this much wiring.u can fix defrost timer for hetar and bimetallic.pcb board also no need.your refigerator working normaly.but sir u doing good job .i am from india
Bhai normal fridge ok inverter main convert karny ka kitna karcha ata hai
Inverter compressor mein pcb change krne ki zarurat to nhi hoti....? Old compressor ki
My no frost fridge consumes 0.9 Amperes. Can I replace my no frost fridge compressor to inverter compressor? at the moment it has Panasonic R134a fitted, original compressor.
love you sir
Very nice
Good job thanks ❤
Ap ne relay k kon kon se point use kiay hen koi mention nai kia rrelays ka function b nai btaya k kis purpose k liay use kr rahe hen r kb r kon c relay on hogi
Zaberdust 👍
Sir 134a ka running prusser kitne dain gy
Thanks 👌 😊 ❤
very good job
Kitna kharcha ata he totally convert krne py ?
وعلیکم السلام
جزاكَ اللّٰه
inverter AC has one inner and one outer card, If there is any fault in any of the two cards, inverter AC doesn"t work,it won't even start. What about inverter fridge, doesn't it have any card? It means it is very easy to convert normal to inverter fridge. Then why people replace Their AC, why don't they change to inerter compressor?
Can we apply the same tachnique to Freezer?
It do have Pcb Board, I do have shown it in the video.
Which company best inverter fridge dawlannce hair or other
Your gas charging is good. Proper procedure.
❤❤Excellent ❤❤
Is relay ko hum nhi lagay to kiya masla ayega ???
heater jal jayega yah kam nahi karega, jo defrost heater evaporator kaye piche laga hota hai.
I want to do this in my fridge
Good 👍 job sir
Thanks
Hum ye kar chukein hain 0.4 2 saal pehle non inverter ac bhi
Good
this will work on embraco inverter compressors
yes this is embraco inverter compressor
Nice g video
Nice
Sir agr r600 compresser lgata wo zada best hota
Total cost ??
Ismein kharcha Kitna aay ga
Price kia ha inverter compreser ka
Yah Change hota rehta hai dollar Pai depend krta, Abhi ka rate pata karna pare ga
Relay zarori he sirf thermostate ke sath connection nahi hu sakte itna pacheeda kam ki kaya zaroorat he?
Good presentation, but you can split into 2 or 3 parts. It's too long.
Compressor ky price bataein ya contact nomber
Iska hi aik chota sa AC bna dien jo itna hi load ly mazay
Vapor nahi compress hone per gas High pressur liquid hoti hai (liquid fom main hoti hai) condenser ke bat low pressur liquid ho jati hai. capillary ke bad main low pressur vapor banti hai.
.1 ampere jab inverter ki cooling poori ho jati hai , iss halat mein non inverter band ho jata hai matlab 0 ampere , cooling ke time dono brabar ampere letay hain
But jab compressor non- inverter ka start wapis hota hai tu, 8 amperes ka jhatka laye kar start hota hai, jabke inverter mai aisa nahi hota.
bhai apki location Kia hay
Sir aap ki vedio mein Filter ka position upto down hona chaiye per aapne niche lagaya hau.....koi farak padta hai ki filter koi bhi position lagane se
Ise Koi Fark nahi Parta Usne sirf gas ko filter karna hota hai
So lenghty process
❤
کہا آپ نے نارمل فریج کو انورٹر فریج میں کنورٹ کیا ہے
G bilkul kiya hai video puri dekhaien janab
Beat thing is that you charged by weight many peoples do bakc pressure. Back pressure is bad because is varies on environment temperature.
Sir inverter py to r 600 gas dalta hi aap ne r134a gas charge kiya hi q
inverter compressor r134a mai bhi ate hain , sirf r600a ka nahi hota, balke r600a mai bhi non inverter compressor ate hain. Aur 134a gas charge hie isiliye ki kiyon kaye yah compressor r134a ka inverter compressor tha.
@@ForeverTechHindi sir cooling ice jamane ke leye best konsa inverter hi r600a gas wala ya r134a gas wala
Sir I think you have a little Miss understanding, you said gas is liquid from in filter, but if gas is liquid from in filter then capillary must could be choke and your system is not working properly
Bhai
Aapne direct line deker kyu nahi check kiya,
normal compressor 1.2 amperes Leta hai just and inverter 0.8 amp.
The procedure of realising gas is not recommended pls use recovery cylinder or put pipe of realise gas water tank or bottle instead realising in Air
Galat bataya aapne sir .. Normal Compressor ka RPM 2850 hota hai 😊
Thanks information kaye liye, Har compressor ka ek dusre sai mukhtalif ho sakta hai
Ap Ne Thimble me dikhaya hy k normal fridge 6.1 Amp 😅😅😅