Potential Transformer MK box wiring || Hindi || Part - 2

Поділитися
Вставка
  • Опубліковано 28 лис 2024

КОМЕНТАРІ • 44

  • @RavikumarEVB
    @RavikumarEVB 3 місяці тому +1

    बहुत ही अच्छे तरीके से समझाया सर धन्यवाद

  • @ashishvitekar3474
    @ashishvitekar3474 2 роки тому

    Very nice explain and very informative video's keep it up

  • @nareshkumar4530
    @nareshkumar4530 2 роки тому

    आपके समझाने का तरीका बहुत ही अच्छा है धन्यवाद 🙏🙏

  • @justwelltariang2456
    @justwelltariang2456 2 роки тому

    Thanks bro for your valuable ideas that you have shared. Immensely benefitted.

  • @tapankakadia2009
    @tapankakadia2009 3 роки тому

    Gajjab Gajjab saheb 💖

  • @swapnajitkonwar3540
    @swapnajitkonwar3540 7 днів тому

    Sir,Please clarify if we can use the Broken delta configured secondary winding of a 33KV PT for Non-directional Earth fault protection or Overvoltage protection in a 33/11KV Substation?..if yes,then kindly share a video for wiring a Broken delta PT secondary from MK box to C&R panel.

  • @mukeshkadiya4132
    @mukeshkadiya4132 2 роки тому

    Nice vedeo sir
    good keep it up

  • @mohammedlatif8999
    @mohammedlatif8999 Рік тому

    Great teacher

  • @deepankajviet
    @deepankajviet 6 місяців тому

    Please make 400 kV substation videos also at. different equipments

  • @sunilkumar-md7rj
    @sunilkumar-md7rj 2 місяці тому

    Thank you so much sir ji

  • @dev7714
    @dev7714 Рік тому

    Valuable video

  • @ZYXYZLF
    @ZYXYZLF 3 роки тому +2

    Well explained 👏, thanks for sharing valuable, knowledgeable information about Potential Transformer PT.
    I have a Question ( play video 07:30 ) about secondary FUSE ampere ratings and class. I hope you will reply. Once again thanks

    • @Insighttecs
      @Insighttecs  3 роки тому

      The PT fuse ratings are gradually increase from end use i.e.relay, energy meter, etc... Towards PT MK box... And PT secondary box.. That are starting from 2 amp to the 16 amp...
      We hope your doubt is clear now.
      Thanks for watching 👍

    • @mehavaghela8896
      @mehavaghela8896 Рік тому

      ​@@Insighttecs સર ખૂબ જ સર, sir, સરળ શબ્દોમાં તમે સમજાવ્યું👍👍. પણ relay પેનલ થી સેકન્ડરી બોક્સ તરફ જતા શા માટે fuse ના રેટિંગ વધે છે???

  • @babluprasad2757
    @babluprasad2757 2 роки тому

    Very nice

  • @AS-kb7gy
    @AS-kb7gy 3 роки тому

    Thanks for sharing valuable information

  • @Md-bu3fl
    @Md-bu3fl 3 роки тому

    Hey,you are geniuses

  • @surendrakverma555
    @surendrakverma555 2 роки тому

    Very good. Thanks 🙏🙏🙏🙏🙏🙏

  • @rakeshprmnk832
    @rakeshprmnk832 9 місяців тому

    Nice

  • @sanjaymishra1028
    @sanjaymishra1028 8 місяців тому

    SHUKRIYA

  • @studtech138
    @studtech138 Рік тому

    Good

  • @abhishekpathania2262
    @abhishekpathania2262 2 роки тому

    Sir isme open delta vi to use krte h vo ku use krte h

    • @Insighttecs
      @Insighttecs  2 роки тому

      directional features of earth fault ko use karne k lie.....
      directional earth fault relay....

  • @pratiktank4786
    @pratiktank4786 3 роки тому

    Nice information.

  • @vijaypratap7060
    @vijaypratap7060 Рік тому

    ❤❤❤

  • @amolgongane307
    @amolgongane307 Рік тому

    Why pt fuse is used in secondary?

  • @samexgaming9823
    @samexgaming9823 3 роки тому

    You Rocks from Joining

  • @appliedelearning8651
    @appliedelearning8651 3 роки тому

    Thank you very much.

  • @carryMinaat
    @carryMinaat 3 місяці тому

    bhai primary ko ground Karega ,,,
    to earth fault nahin ho jaega --- circuit trip nahin Karega kya 🤔🤔

    • @Insighttecs
      @Insighttecs  3 місяці тому

      no, as the winding is a load to the circuit...
      as the star type transformer, there is a neutral is earthed, when it is in service, and the neutral is the secon terminal of phase wire in transformer.

    • @Insighttecs
      @Insighttecs  3 місяці тому

      no, as the winding of pt is a load to the circuit,
      like star winding of transformer, the netural is earthed, and the netural is the second terminal of phase winding.

  • @krishnaRajput-mf4dq
    @krishnaRajput-mf4dq 3 роки тому

    Thank you sir

  • @shobharajjayswal7346
    @shobharajjayswal7346 3 роки тому

    👏👏

  • @justwelltariang2456
    @justwelltariang2456 Рік тому

    The neutral point of the HV side is shown that it is connected to N, I. e earth. Could you elaborate how this is possible, otherwise it will be shorted as phase to ground fault. 😮

    • @Insighttecs
      @Insighttecs  Рік тому

      its not... as the winding of pt is comes between HV point and neutral.. so, it will not create line to ground fault.
      winding act as load... just like EHV reactors

  • @durgeshbisht971
    @durgeshbisht971 2 роки тому

    One one ten volt ?

  • @jitendramittal2539
    @jitendramittal2539 2 роки тому

    Please provide the video for 132 kv PT WIRING

    • @Insighttecs
      @Insighttecs  2 роки тому

      you can execute the 132kv pt wiring same as per video...
      all PT wiring are same,
      if any doubt, ask for the perticuler doubt...
      best of luck....

    • @jitendramittal2539
      @jitendramittal2539 2 роки тому

      @@Insighttecs Thank you 🙏🙏.... Please let me know should We use open delta in PT for protection circuit or not if yes then for all ratings PT or for any specific Ratings PT???

  • @Technoman98
    @Technoman98 Рік тому

    MK Box full form?

  • @gauravsinghal2598
    @gauravsinghal2598 Рік тому

    Why we use fuse in PT and not use in CT

  • @jensuva9868
    @jensuva9868 2 роки тому

    Thanks you sirji

  • @kdaksh1996
    @kdaksh1996 Рік тому +1

    Thank you sir