Це відео не доступне.
Перепрошуємо.

Reinforcement details of Plinth Beam for 2 Storey House | 2 मंजिला घर के लिए प्लिंथ बीम का सरिया

Поділитися
Вставка
  • Опубліковано 4 чер 2021
  • Disclaimer - This video is for educational purposes only. Copyright Disclaimer under section 107 of the copyright act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship, and research. Fair use is a use permitted by copyright statutes that might otherwise be infringing. Non-profit educational or personal use tips the balance in favor of fair use.
    Reinforcement details of Plinth Beam for 2 Storey House | 2 मंजिला घर के लिए प्लिंथ बीम का सरिया
    अगर आप इस Slide की pdf copy चाहते है तो हमारी वेबसाइट www.myengineeringsupport.com पर visit करके आप ये pdf download कर सकते है या फिर आप हमे direct message करे हमारे instagram और telegram group पर आपको PPT और PDF दोनों भेज दी जाएगी !
    TOPIC COVER:-
    plinth beam bar Reinforcement,
    reinforcement plinth beam height
    2 मंजिला घर के लिए प्लिंथ बीम का सरिया
    Reinforcement details of Plinth Beam for 2 storey House
    plinth beam reinforcement details
    plinth beam steel details
    plinth beam size for house
    plinth beam design
    plinth beam thickness
    plinth beam concrete ratio
    Important Articles
    20 Interview Questions and Answers For Civil Engineers
    myengineerings....
    15-technical-terms-about-reinforcement
    myengineeringsu....
    How to Calculate Required No. Of Tiles For Flooring
    myengineerings....
    STRUCTURAL SYSTEM OF BUILDING/LOAD-BEARING STRUCTURE, FRAMED STRUCTURE, AND COMPOSITE STRUCTURES
    myengineerings....
    WHAT IS GUNIA IN CONSTRUCTION // HOW TO MEASURE GUNIA
    myengineerings....
    Different types of steel bars used in construction /Full Form full Explanation
    myengineerings....
    Minimum and Maximum Distance Between Two Columns?
    myengineerings....
    Types of Safety Helmet in Construction
    myengineerings....
    Basic Functional Requirements of Building
    myengineerings....
    How to Find Width & depth of Beam
    myengineerings....
    Load bearing & Framed Structure
    myengineerings....
    Standard Room Sizes for Residential Building in India
    myengineerings....
    Bricks in 1 Cubic Foot - Calculation
    myengineerings....
    Types of Loads on Foundations & Building Structure
    myengineerings....
    How to Calculate Rectangular Tank sizes & Capacity
    myengineerings....
    Bar Bending Schedule Of Footing (BBS) & Steel Quantity in Footing
    myengineerings....
    Quantity of bricks & mortar - How to Calculate the Number of bricks in the wall
    myengineerings....
    Bar Bending Schedule of Beam ( BBS )
    myengineerings....
    Components Of A Building Structure
    myengineerings....
    Bar Bending Schedule Basics: Especially for Freshers Civil Engineers Kindle Edition
    amzn.to/3uvEMNo
    My Social Media Link:-
    Telegram Link:-
    t.me/yoursengi...
    Facebook page:-
    / yoursengineer
    Facebook group:- / yours. .
    Twitter link:- / yoursengineer
    Instagram link:- / yoursengineer
    Pinterest:- / myengineerin. .
    Linkedin:- / vishal-go. .
    Website:- myengineeringsupport.com
    Accessories I Use for making Videos
    Mic I use - amzn.to/3r5f1S6
    The laptop I use - amzn.to/3ayYNu3
    Laptop Stand I Use- amzn.to/3cnILpj
    _______________________________________________________
    LIKE | SHARE | SUBSCRIBE FOR MORE VIDEOS LIKE THIS
    ~
    THANKS FOR WATCHING! -ENJOY
    ===============================

КОМЕНТАРІ • 231

  • @zainulaabdeen1786
    @zainulaabdeen1786 3 роки тому +2

    Very nice video sir ji bahut hi achcha tarika se aap ne samjhaya hai aap ne Masa allah

  • @acharya6
    @acharya6 3 роки тому +1

    बहुत ही अच्छा, संक्षिप्त और जानकारी बातें करी हैं सरजी आपने।

  • @NITINSINGH-ec3if
    @NITINSINGH-ec3if 3 місяці тому

    Aap bahut achey sey batatey hai..❤

  • @yashwantikumari8311
    @yashwantikumari8311 2 роки тому +1

    बहुत ही अच्छी जानकारी.

  • @pradeeshpradeesh3924
    @pradeeshpradeesh3924 3 роки тому +2

    Thank you Bro... frm Kerala

  • @shyambhoidoctornameplease3513
    @shyambhoidoctornameplease3513 2 роки тому +1

    Nice voice great Sir thank you

  • @pradeepnarayansharma9001
    @pradeepnarayansharma9001 Рік тому

    Very good information for layman

  • @armyofficermanishsharma5039
    @armyofficermanishsharma5039 3 роки тому +3

    Good morning sir

  • @pradeepnarayansharma9001
    @pradeepnarayansharma9001 Рік тому

    Very Informative

  • @saviocorrea6159
    @saviocorrea6159 2 роки тому +1

    Thaks

  • @anonymoushacks637
    @anonymoushacks637 2 роки тому +2

    Love you sir

  • @RK-MAHAVADI
    @RK-MAHAVADI 2 роки тому +2

    Good explanation along with appropriate specifications & codes 👌

  • @ravikantverma1642
    @ravikantverma1642 2 роки тому

    Best video i have seen ever

  • @bharatyadav3619
    @bharatyadav3619 2 роки тому +1

    Nice information...👍❤

  • @ImranKhan-nz8ll
    @ImranKhan-nz8ll 2 роки тому +4

    I get perticular information from this video which i wanted to know

  • @skshal4u
    @skshal4u 2 роки тому +1

    Very good description in a shorter video.

  • @mytechnicalsupport1992
    @mytechnicalsupport1992 3 роки тому +2

    Good👍👍Good

  • @abraralam5275
    @abraralam5275 2 роки тому +1

    Gooood

  • @karmajamatia8260
    @karmajamatia8260 11 місяців тому

    Ok sir

  • @er.mohinderpmamualiya7213
    @er.mohinderpmamualiya7213 2 роки тому +1

    Good

  • @healthcareadvisor4880
    @healthcareadvisor4880 2 роки тому +1

    Thank you

  • @mramit6925
    @mramit6925 2 місяці тому

    Bhai ji mujhe chhat dalwani hai Ghar ki ground floor hai, future me 1 floor or banane ka plan hai,
    Rajgir ne 10mm or 12 mm ka steel suggest Kia hai , and ring 7x7 ka bola hai kya ye thik hai,

  • @hassannawaz1204
    @hassannawaz1204 Рік тому +1

    Kya plinth beam under room side ka dpc leval pr coloum se connect kr sakte hain

  • @axatrathod
    @axatrathod 2 роки тому +1

    👌🏼👌🏼👌🏼

  • @JoginderSingh-nz2rd
    @JoginderSingh-nz2rd Рік тому +1

    My egeeneer sport

  • @nishadzala4488
    @nishadzala4488 3 роки тому +3

    good evening sir

  • @fhzhf
    @fhzhf 3 місяці тому

    Sir ji 3 stories house ki liye bhi plinth beam ki same condition rahegi ya change hogi

  • @SaleemKhan-zk4vw
    @SaleemKhan-zk4vw 2 роки тому +1

    40 बाई 50 का बेस्ट मैन तीन फ्लोर ऊपर

  • @krishanhooda291
    @krishanhooda291 2 роки тому +1

    Teen majila k liye bhi bataye pl

  • @nileshgadade2945
    @nileshgadade2945 2 роки тому +1

    2 flor ke column me 10 mm ke sariya hai koi problem hoga kya slab takne ke baad

  • @HabesAli7429
    @HabesAli7429 2 роки тому +1

    Bohut boriya thank u sir please m no plase

  • @sonukumar-kv3bs
    @sonukumar-kv3bs 2 роки тому +1

    Outer wall की मोटाई कितनी रखना सही है...10" या 5" इंच

  • @rishikandwal1761
    @rishikandwal1761 2 роки тому +1

    आपकी दी गयी जानकारी बहुत महत्वपूर्ण है।इसके लिए आपका धन्यबाद।मै भविष्य में मकान बनाना है ।कृपया मुझे मकान बनाने के लिए आवश्यक जानकारी मेरे इसी नंबर पर देने की कृपा करें।

  • @lapakana
    @lapakana Рік тому +1

    I have 6 continuous 12 mm rods in my beam. To attach to colum i bent 4 rods (side rods) in horizontal L shape (180degree) and middle rods in vertical L shape (45 degree). Each rod i bent is 7 inch. Is that ok ?

  • @AchiniBoruah
    @AchiniBoruah Рік тому +1

    Sir.....hamare gitti(stone) ke sath mitti mix hai .....aur ushi se hi mistri ne Footing aur beam ki dhalai kar di hai..... future mai koi dikkat hoga kya?? RCC G+1 bana raha hoon... please reply sir

  • @souravmondal2606
    @souravmondal2606 2 роки тому +1

    Sir
    Bottom me 3 - 12mm and top me 2 - 10mm ka bar use kara jayega 2 stories building kalie.
    SRMB/ELEGANT brand ka Bar use karajayega?

  • @networking22
    @networking22 2 роки тому +3

    These details are for standard house. What if house is very small . Like 450 sq feet, two floors. Where distance between walls is very less. In that case , size will vary along with grade of concrete?

  • @IshanShukla
    @IshanShukla Місяць тому

    Development length, top extra bottom extra kuch btaye ni

  • @Riyaj_Tech
    @Riyaj_Tech Рік тому

    Sir hamne g+2 ka makaan banwaya hai jo 10/37 ka hai jisme taai beam 9/12 6 sariya 12 mm ka 3 top me aour 3 bottem me jisme 10/10 ka collam ka distenc hai ek 10/12 ka hai lekin sir collam me 4 hi sariya hai 12 mm ka kya karoo mistri ne bhi nahi bataya kya Ghar gir sakta hai collam size 9/9 ka 4 sariya 12 mm ka hai

  • @ManojMaurya-zh4ci
    @ManojMaurya-zh4ci 2 роки тому +1

    Sir mera ghar ban raha hai jisme 2 pillar ko kat kar bagal me directly plenth beem par khada kar sakte hai plse btaiye

  • @kunalpoddar9353
    @kunalpoddar9353 Рік тому

    Plinch filing may miti ya ret ka use keu

  • @basudebdas6141
    @basudebdas6141 Рік тому

    Kindly say about plinth beam covering &
    how the bar place at end portion of beam
    and also T junction of plinth beam?

  • @ajitseal2486
    @ajitseal2486 5 місяців тому

    Plinth beam ko rod binding design kesa hoga

  • @hassannawaz1204
    @hassannawaz1204 Рік тому

    Ek baat aur puchna tha sir... Kya 7×9 ring plinth beam me use kr sakte hain G+1 house k liye.... Contractor bol raha hai use kr sakte hain

  • @haryanvi7236
    @haryanvi7236 2 роки тому +1

    81*12 feet is interim dimension of room pls suggest column +beam +plinth besm+footing+roof slab... It's residential g+1 story

  • @dibyasensahoo2519
    @dibyasensahoo2519 2 роки тому +1

    Main 12mm ka(top 2nos btm 2nos) maximum span 15feet main use kiya hn kya ye 1st floor banane keliye load bear kar lega ??

  • @sandipgarai4252
    @sandipgarai4252 5 місяців тому

    Can I used 6 mm ring bar in beam and column wheee 2 coloumn distance by 12 ft

  • @madhavbagfarmnursarynursar4532
    @madhavbagfarmnursarynursar4532 6 місяців тому

    3 manjile ke liye bhi bataye

  • @DStechinfo93
    @DStechinfo93 2 роки тому +1

    Sir mera 800 sqft me 2 Chad ho raha he jisme 10 Pilar hoga 10/10 ka our steel usme 12mm ka 6 dal raha hu, future me 2 mangila ke upar me bahar dibar our upar me tin roof kardu to kya aisa kiya ja sakta he??

  • @TheDoctorDiary
    @TheDoctorDiary Рік тому

    Sir mere ghr mein 9x9” ka plinth beam hai or column ki duri 10ft se zyada nahi hai..12mm sariya use hua hai kya isme 3 manjila bana skte hai? G+2? Or column 12” bhi hai or 9” wale bhi hai

  • @muktitiwari1718
    @muktitiwari1718 2 роки тому +1

    Aur 1st floor 2nd floor 3rd floor 4th floor 5th floor k beam ka bhi sariya detail bataye please

  • @aryanamipara153
    @aryanamipara153 3 місяці тому

    2 riang ki duri 150 mm se jayada rakh skate he

  • @samrock4279
    @samrock4279 2 роки тому +1

    Sir 9"×12" piller me 18fit distances
    Or plinth Bim 9"×12" ka hai 16mm 4 bar and 12mn extra bar hai
    Slab Bim ka kya aize rakhe g+1 plis sir bataye

  • @sanjibshaw5277
    @sanjibshaw5277 2 роки тому +1

    Road banhane ka tarikh bhi bata dijiye

  • @SatishKumar-nt4gq
    @SatishKumar-nt4gq 2 роки тому +1

    Sir maine apna ghar bana raha hu to 2 pillar ke bich distance 16fit hai plinth beam ka size 10×15 hai isme rod 12mm ka 5 lagaye hai 3 niche or 2 top me pillar ke bich 16mm ka 2 cutt pic supporting Diya gaya hai
    Sir humko 3 mangila banana hai koi dikkat hai kya isme

  • @r.k.sharma9095
    @r.k.sharma9095 2 роки тому +1

    सर मेरा प्लॉट साइज 1000 स्क्वायर फीट है प्लिंथ बीम में 12 एमएम का सरिया ढल गया है गलती से बेस तैयार हो गया यह सही है या अगर गलत है तो इसका उपाय क्या है सही करने प्लीज थोड़ा बताइएगा आपका नंबर भी दे दीजिएगा सर

  • @ansarisahab1786
    @ansarisahab1786 2 роки тому +1

    Agar Kursi ki hight zameen se 12 feet ke upar Ho Jaise Nala ke pass use Waqt plinth beam Ke Niche typing dena anivarya hai ya nahin aur uska kya size hona anivarya hai

  • @T.R.i.u.M.p.H
    @T.R.i.u.M.p.H 2 роки тому

    सर, मुझे अपने घर में ग्राउंड लेवल से चार फुट ऊपर फ्लोर लेवल और उसके 10 फुट ऊपर रूफ देना है। इस तरह ग्राउंड बीम और रूफ बीम के बीच का हाइट 13 फिट हो जाता है क्या सिर्फ ग्राउंड लेवल पर एक बीम देने से काम चल जाएगा या बीच मैं प्लिंथ बीम देना जरूरी है।

  • @ramakantapradhan7932
    @ramakantapradhan7932 2 роки тому +1

    Hi, if i wish to provide 18' distance in column to column with provide 16mm dia 4bar, any problem (column size 9*12) with 6bar 12mm & same as beam size ) plz suggested, thanku 🙏

  • @abraralam5275
    @abraralam5275 2 роки тому +1

    MAIN GRIB AADMI HUN MERA PM AAWAS AAYA HAI OR BEHTRI 2 MNJILA GHR BNANA CHAHTA PR MERE PAS BJT NAHI HAI KYA KRUN

  • @sanjeevsingh-iq8ex
    @sanjeevsingh-iq8ex Рік тому

    I have 40 ft by 40 ft site. Total 16 columns.
    All Plinth beam is 1.5 ft by 6 inch.
    At Two specific location can we reduce height of plinth beam to 1ft by 6 inch.

  • @pintubehera1276
    @pintubehera1276 Рік тому

    Footing khudai ke liye marking kaise kare? Kripiya replay sir

  • @tubetech6697
    @tubetech6697 2 роки тому +1

    Mp birla chetak cement kaisa hai

  • @ravikantverma1642
    @ravikantverma1642 2 роки тому +1

    Sir what will be the size of pit or digging the ground for two story building. Can it will be 2×2×2 feet.

  • @akhlaquekhan449
    @akhlaquekhan449 2 роки тому +1

    धन्यवाद श्रीमान,लेकिन हमने घर बनाया है,उसमे पलिथ बीम की रिंग 7×7 हैं जिसमे 12 mm का 6 सरिया दिया है,इसमे हमारी गलती नहीं है,ठेकेदार ही जैसा बोला वैसा किया,अब किया कर सकते है सर?कोई समस्या तो नहीं होगा न?

    • @myengineeringsupport
      @myengineeringsupport  2 роки тому +1

      Floor kitne h

    • @akhlaquekhan449
      @akhlaquekhan449 2 роки тому

      @@myengineeringsupport अभी फिलहाल एक ही फ्लोर बना हुआ है,लेकिन दो फ्लोर तक ही रहेगा सर

  • @laxman098
    @laxman098 2 роки тому +1

    Tu Mala Manjil ka chad main ppc cement aur local Sariya Dene Se Kuch problem Hoga Kya

  • @INDIAN16175
    @INDIAN16175 3 роки тому +1

    Same 2story k liye column aur foundation par bhi video banao

  • @pradeepkushwaha9872
    @pradeepkushwaha9872 2 роки тому +1

    Mera column to colum distance 20 feet h .
    Beam ka steel kitna rakhna chahiye

  • @kaushikmistry7974
    @kaushikmistry7974 2 роки тому +1

    Sir plinth beam de raha hoon DPC dena jaruri hain

    • @myengineeringsupport
      @myengineeringsupport  2 роки тому

      Vaise to dono dena sahi rehta hai par kaam chal jayega plinth beam se bhi

  • @shantikumar4185
    @shantikumar4185 2 роки тому +1

    दीवार 10इंच हो तो पीलाड़ 9 इंची होगा

  • @EDUCATIONNOTES
    @EDUCATIONNOTES 2 роки тому +1

    Tie Beam Niche Guard Wall ka height kitna dena hoga ?

  • @satpalbhiduri8948
    @satpalbhiduri8948 2 роки тому +1

    Sir kya hum G+3 ke liye beam size 9/12 aur ush m sariya 12 mm ke 6 dia use kr skte h aur column to column ka distance 14 ft h

  • @jkfuntalk9594
    @jkfuntalk9594 7 місяців тому

    Plinth beam ko 3feet me rakhenge to DPC ko kitne me denge

  • @laxman098
    @laxman098 2 роки тому +1

    Ek Mala Manjil Mein 16 culam hai but 2 manjit main culam nahi denge Tu chalega..plz help

  • @kaushikraha2893
    @kaushikraha2893 11 місяців тому

    3 manjila ka plinth beam ka reinforcement batayen please

  • @surajsarkar519
    @surajsarkar519 2 роки тому +1

    Sir mani ek ghar main 16 feet column distance main plinth beam ka reinforcement mai 12 mm top main or bottom main 16 mm ka bar dia hai or 12 mm ka extra support in column corneer main dia hai,,, kya ye G+1 building k liye sahi hai

  • @shyamkumarmehra7323
    @shyamkumarmehra7323 Рік тому

    Sir plinth beam mein crank bar provide karte hai ya nhi?

  • @shahlalhashmi
    @shahlalhashmi Рік тому

    junction pe bar kaise provide karne h wo to bta dete

  • @muktitiwari1718
    @muktitiwari1718 2 роки тому +1

    5 manjil k makan me ground beam ka sariya detail batayiye pls

  • @kumarsinnghpankaj8449
    @kumarsinnghpankaj8449 2 роки тому +1

    Sir hame naksha banwana hai 32*32east facing

  • @SanjayKumar-lm2mk
    @SanjayKumar-lm2mk 2 роки тому +1

    Lilith bim ke upar 5 fit ke bad bim dena jaruri hai

  • @maharajsahani6195
    @maharajsahani6195 Рік тому

    Chhat ki dhalai ke liye

  • @modanidarshana4247
    @modanidarshana4247 2 роки тому +1

    Please more than 16' feet Ka steel details Ka videos banaye...yeah video toh bohat hai youtube par... mujhe more than 16' feet ke hona

  • @bibidhabharatibangla
    @bibidhabharatibangla 2 роки тому +1

    Four manjila Ghar ki plinth beam Ka reinforcement details kiya hoga please batana.

  • @praveenkumarshayar5573
    @praveenkumarshayar5573 3 роки тому +1

    Aapne extra bar ke bare nhi btaya is video me. Extra bar nhi dena h kya ??? Pls reply. Agr extra bar dena h to size kya dena h .Pls reply. Mera ghr Ka plinth beam bnane vala h 1 ya 2 din me.

    • @myengineeringsupport
      @myengineeringsupport  3 роки тому

      ua-cam.com/video/wLwEe1wqNnI/v-deo.html
      Watch it

    • @praveenkumarshayar5573
      @praveenkumarshayar5573 3 роки тому

      Is video me length of extra nhi btaya gya h..kis jgh dena dena h ?? Residential 2 story building ke lie extra bar dena compulsory h ya optional h??pls reply

    • @myengineeringsupport
      @myengineeringsupport  3 роки тому

      For any query
      😀😀Follow this link to join my Telegram group:
      Join this Group, Special for civil Engineers & Architects.
      t.me/joinchat/Vig1gIW41fUtqIfW

  • @maheshthakar
    @maheshthakar 3 роки тому +3

    How much cover as per IS code for column, beam and slab?

  • @satishgupt929
    @satishgupt929 2 роки тому +1

    Mujhe 25*77 me ground flore sirf hall rakhna hai to plinth aur top BIM me kitne mm ka sariya de

  • @BABLUKUMAR-ts1jo
    @BABLUKUMAR-ts1jo 2 роки тому +1

    Simple ground floor Banane Mein Kitna kharch aaega sar

  • @AshishSharma-zi1xs
    @AshishSharma-zi1xs 2 роки тому +1

    Sir what should be the beam size for 20 feet column to column distance

  • @krushnaguruburda.2852
    @krushnaguruburda.2852 2 роки тому +1

    sir plinth beam distance 15 fit used 4 rod (16mm top & 12mm bottom ) 2 floor k liye sehi he

  • @SachinTomar_Civil_Engineer
    @SachinTomar_Civil_Engineer 2 роки тому +1

    30x40 plot size I am giving 6 bars .
    4 nos 12 mm
    2 nos 10 mm
    Beam size 9 inches by 12 inches

  • @Anindian896
    @Anindian896 2 роки тому +1

    G+2 Ghar me colom me 12 mm steel 4 pic dia hun sir galat Kia hun kya sir plz reply me?

  • @mukeshsoni488
    @mukeshsoni488 Рік тому

    Aap Gujarati legvej malacan moklo

  • @gopalmalviya322
    @gopalmalviya322 Рік тому

    15 फिट दुरी मे कालम व रुफ बिम मे सलिया व कालम की साईज क्या दे

  • @mygarden2694
    @mygarden2694 2 роки тому +1

    Column size kitna....

  • @naimsiddiquee8806
    @naimsiddiquee8806 Рік тому

    SIR GROUND FLOOR.+2 KA VIDEO BEJNA

  • @subhamsingam
    @subhamsingam 2 роки тому +1

    Plinth beam mein 10dayi6pis theek hai jindal

  • @ajitdoley4876
    @ajitdoley4876 Рік тому

    hi

  • @deepakguptavlogs8539
    @deepakguptavlogs8539 Рік тому

    Kuchh log 10mm ka sariya plinth beam me dal deta hai to use koi dikkat hai।

  • @bikymalakar3569
    @bikymalakar3569 3 роки тому +1

    Sir hamara toh 6mm ring 5cm center too center de diya
    Only g+1 building ke liye problem hogi kiya sir please rply

    • @myengineeringsupport
      @myengineeringsupport  3 роки тому

      Bilkul galat kiya yaar

    • @bikymalakar3569
      @bikymalakar3569 3 роки тому

      @@myengineeringsupport dikkat hogi kiya ??

    • @myengineeringsupport
      @myengineeringsupport  3 роки тому +1

      Nhi spacing 2inch hai to koi problem nhi hai

    • @bikymalakar3569
      @bikymalakar3569 3 роки тому +1

      @@myengineeringsupport thanks sir... Spacing 4cm hain
      Mera Foundation ho gaya
      Ab main Foundation ke upar 8mm laga du kiya sir ?

    • @myengineeringsupport
      @myengineeringsupport  3 роки тому

      Han sabhi stirrups dia 8 ka kro beam ho ya column