Це відео не доступне.
Перепрошуємо.
Reinforcement details of Plinth Beam for 2 Storey House | 2 मंजिला घर के लिए प्लिंथ बीम का सरिया
Вставка
- Опубліковано 4 чер 2021
- Disclaimer - This video is for educational purposes only. Copyright Disclaimer under section 107 of the copyright act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship, and research. Fair use is a use permitted by copyright statutes that might otherwise be infringing. Non-profit educational or personal use tips the balance in favor of fair use.
Reinforcement details of Plinth Beam for 2 Storey House | 2 मंजिला घर के लिए प्लिंथ बीम का सरिया
अगर आप इस Slide की pdf copy चाहते है तो हमारी वेबसाइट www.myengineeringsupport.com पर visit करके आप ये pdf download कर सकते है या फिर आप हमे direct message करे हमारे instagram और telegram group पर आपको PPT और PDF दोनों भेज दी जाएगी !
TOPIC COVER:-
plinth beam bar Reinforcement,
reinforcement plinth beam height
2 मंजिला घर के लिए प्लिंथ बीम का सरिया
Reinforcement details of Plinth Beam for 2 storey House
plinth beam reinforcement details
plinth beam steel details
plinth beam size for house
plinth beam design
plinth beam thickness
plinth beam concrete ratio
Important Articles
20 Interview Questions and Answers For Civil Engineers
myengineerings....
15-technical-terms-about-reinforcement
myengineeringsu....
How to Calculate Required No. Of Tiles For Flooring
myengineerings....
STRUCTURAL SYSTEM OF BUILDING/LOAD-BEARING STRUCTURE, FRAMED STRUCTURE, AND COMPOSITE STRUCTURES
myengineerings....
WHAT IS GUNIA IN CONSTRUCTION // HOW TO MEASURE GUNIA
myengineerings....
Different types of steel bars used in construction /Full Form full Explanation
myengineerings....
Minimum and Maximum Distance Between Two Columns?
myengineerings....
Types of Safety Helmet in Construction
myengineerings....
Basic Functional Requirements of Building
myengineerings....
How to Find Width & depth of Beam
myengineerings....
Load bearing & Framed Structure
myengineerings....
Standard Room Sizes for Residential Building in India
myengineerings....
Bricks in 1 Cubic Foot - Calculation
myengineerings....
Types of Loads on Foundations & Building Structure
myengineerings....
How to Calculate Rectangular Tank sizes & Capacity
myengineerings....
Bar Bending Schedule Of Footing (BBS) & Steel Quantity in Footing
myengineerings....
Quantity of bricks & mortar - How to Calculate the Number of bricks in the wall
myengineerings....
Bar Bending Schedule of Beam ( BBS )
myengineerings....
Components Of A Building Structure
myengineerings....
Bar Bending Schedule Basics: Especially for Freshers Civil Engineers Kindle Edition
amzn.to/3uvEMNo
My Social Media Link:-
Telegram Link:-
t.me/yoursengi...
Facebook page:-
/ yoursengineer
Facebook group:- / yours. .
Twitter link:- / yoursengineer
Instagram link:- / yoursengineer
Pinterest:- / myengineerin. .
Linkedin:- / vishal-go. .
Website:- myengineeringsupport.com
Accessories I Use for making Videos
Mic I use - amzn.to/3r5f1S6
The laptop I use - amzn.to/3ayYNu3
Laptop Stand I Use- amzn.to/3cnILpj
_______________________________________________________
LIKE | SHARE | SUBSCRIBE FOR MORE VIDEOS LIKE THIS
~
THANKS FOR WATCHING! -ENJOY
===============================
Very nice video sir ji bahut hi achcha tarika se aap ne samjhaya hai aap ne Masa allah
Thanks
बहुत ही अच्छा, संक्षिप्त और जानकारी बातें करी हैं सरजी आपने।
Thanks brother
Aap bahut achey sey batatey hai..❤
बहुत ही अच्छी जानकारी.
Thanks🙏
Thank you Bro... frm Kerala
My pleasure✨
Nice voice great Sir thank you
My pleasure 🙏
Very good information for layman
Good morning sir
Very good morning🌞 manish ji
Very Informative
Thaks
Welcome 🙏
Love you sir
Thanks🙏
Good explanation along with appropriate specifications & codes 👌
Thanks🙏
Best video i have seen ever
Thanks 🙏
Nice information...👍❤
Thanks🙏
I get perticular information from this video which i wanted to know
My pleasure🙏
39 length 31deafth plan house plinth beam details
Very good description in a shorter video.
Thanks
Good👍👍Good
Thanks
Gooood
Thanks🙏
Ok sir
Good
Thanks
Thank you
My pleasure🙏
Bhai ji mujhe chhat dalwani hai Ghar ki ground floor hai, future me 1 floor or banane ka plan hai,
Rajgir ne 10mm or 12 mm ka steel suggest Kia hai , and ring 7x7 ka bola hai kya ye thik hai,
Kya plinth beam under room side ka dpc leval pr coloum se connect kr sakte hain
Yes
👌🏼👌🏼👌🏼
Thanks 😊
My egeeneer sport
Yes
good evening sir
Very good evening nishad ji
Sir ji 3 stories house ki liye bhi plinth beam ki same condition rahegi ya change hogi
40 बाई 50 का बेस्ट मैन तीन फ्लोर ऊपर
Ok
Teen majila k liye bhi bataye pl
Already btaya hu check another video on channel
2 flor ke column me 10 mm ke sariya hai koi problem hoga kya slab takne ke baad
Nhi galat h bilkul
Bohut boriya thank u sir please m no plase
Welcome🎉
Outer wall की मोटाई कितनी रखना सही है...10" या 5" इंच
9"
आपकी दी गयी जानकारी बहुत महत्वपूर्ण है।इसके लिए आपका धन्यबाद।मै भविष्य में मकान बनाना है ।कृपया मुझे मकान बनाने के लिए आवश्यक जानकारी मेरे इसी नंबर पर देने की कृपा करें।
Thanks🙏
I have 6 continuous 12 mm rods in my beam. To attach to colum i bent 4 rods (side rods) in horizontal L shape (180degree) and middle rods in vertical L shape (45 degree). Each rod i bent is 7 inch. Is that ok ?
Sir.....hamare gitti(stone) ke sath mitti mix hai .....aur ushi se hi mistri ne Footing aur beam ki dhalai kar di hai..... future mai koi dikkat hoga kya?? RCC G+1 bana raha hoon... please reply sir
Mitti mix nhi honi chahiye
@@myengineeringsupport slit mix hai....... straight kitna kamega?
Sir
Bottom me 3 - 12mm and top me 2 - 10mm ka bar use kara jayega 2 stories building kalie.
SRMB/ELEGANT brand ka Bar use karajayega?
Ok
These details are for standard house. What if house is very small . Like 450 sq feet, two floors. Where distance between walls is very less. In that case , size will vary along with grade of concrete?
Yes
use 12mm dia 4 bars
Development length, top extra bottom extra kuch btaye ni
Sir hamne g+2 ka makaan banwaya hai jo 10/37 ka hai jisme taai beam 9/12 6 sariya 12 mm ka 3 top me aour 3 bottem me jisme 10/10 ka collam ka distenc hai ek 10/12 ka hai lekin sir collam me 4 hi sariya hai 12 mm ka kya karoo mistri ne bhi nahi bataya kya Ghar gir sakta hai collam size 9/9 ka 4 sariya 12 mm ka hai
Sir mera ghar ban raha hai jisme 2 pillar ko kat kar bagal me directly plenth beem par khada kar sakte hai plse btaiye
No
Plinch filing may miti ya ret ka use keu
Kindly say about plinth beam covering &
how the bar place at end portion of beam
and also T junction of plinth beam?
Plinth beam ko rod binding design kesa hoga
Ek baat aur puchna tha sir... Kya 7×9 ring plinth beam me use kr sakte hain G+1 house k liye.... Contractor bol raha hai use kr sakte hain
81*12 feet is interim dimension of room pls suggest column +beam +plinth besm+footing+roof slab... It's residential g+1 story
Design it with me 9996656740 What app
Main 12mm ka(top 2nos btm 2nos) maximum span 15feet main use kiya hn kya ye 1st floor banane keliye load bear kar lega ??
Yes
Can I used 6 mm ring bar in beam and column wheee 2 coloumn distance by 12 ft
3 manjile ke liye bhi bataye
Sir mera 800 sqft me 2 Chad ho raha he jisme 10 Pilar hoga 10/10 ka our steel usme 12mm ka 6 dal raha hu, future me 2 mangila ke upar me bahar dibar our upar me tin roof kardu to kya aisa kiya ja sakta he??
Yes
Thank u sir🙏
Sir mere ghr mein 9x9” ka plinth beam hai or column ki duri 10ft se zyada nahi hai..12mm sariya use hua hai kya isme 3 manjila bana skte hai? G+2? Or column 12” bhi hai or 9” wale bhi hai
Aur 1st floor 2nd floor 3rd floor 4th floor 5th floor k beam ka bhi sariya detail bataye please
Already video available on channel
2 riang ki duri 150 mm se jayada rakh skate he
Sir 9"×12" piller me 18fit distances
Or plinth Bim 9"×12" ka hai 16mm 4 bar and 12mn extra bar hai
Slab Bim ka kya aize rakhe g+1 plis sir bataye
Ok hai
Road banhane ka tarikh bhi bata dijiye
Ok
Sir maine apna ghar bana raha hu to 2 pillar ke bich distance 16fit hai plinth beam ka size 10×15 hai isme rod 12mm ka 5 lagaye hai 3 niche or 2 top me pillar ke bich 16mm ka 2 cutt pic supporting Diya gaya hai
Sir humko 3 mangila banana hai koi dikkat hai kya isme
No
Hum jo sariya laga rahe hai usse 3 manjila Ghar banane me koi dikkat to nahi hai na sir
सर मेरा प्लॉट साइज 1000 स्क्वायर फीट है प्लिंथ बीम में 12 एमएम का सरिया ढल गया है गलती से बेस तैयार हो गया यह सही है या अगर गलत है तो इसका उपाय क्या है सही करने प्लीज थोड़ा बताइएगा आपका नंबर भी दे दीजिएगा सर
Check description
Agar Kursi ki hight zameen se 12 feet ke upar Ho Jaise Nala ke pass use Waqt plinth beam Ke Niche typing dena anivarya hai ya nahin aur uska kya size hona anivarya hai
Very compulsory after filling
सर, मुझे अपने घर में ग्राउंड लेवल से चार फुट ऊपर फ्लोर लेवल और उसके 10 फुट ऊपर रूफ देना है। इस तरह ग्राउंड बीम और रूफ बीम के बीच का हाइट 13 फिट हो जाता है क्या सिर्फ ग्राउंड लेवल पर एक बीम देने से काम चल जाएगा या बीच मैं प्लिंथ बीम देना जरूरी है।
Not required
Hi, if i wish to provide 18' distance in column to column with provide 16mm dia 4bar, any problem (column size 9*12) with 6bar 12mm & same as beam size ) plz suggested, thanku 🙏
Ok no issue
MAIN GRIB AADMI HUN MERA PM AAWAS AAYA HAI OR BEHTRI 2 MNJILA GHR BNANA CHAHTA PR MERE PAS BJT NAHI HAI KYA KRUN
Paisa jodo
I have 40 ft by 40 ft site. Total 16 columns.
All Plinth beam is 1.5 ft by 6 inch.
At Two specific location can we reduce height of plinth beam to 1ft by 6 inch.
Footing khudai ke liye marking kaise kare? Kripiya replay sir
Mp birla chetak cement kaisa hai
No idea
Sir what will be the size of pit or digging the ground for two story building. Can it will be 2×2×2 feet.
No minimum 4feet
धन्यवाद श्रीमान,लेकिन हमने घर बनाया है,उसमे पलिथ बीम की रिंग 7×7 हैं जिसमे 12 mm का 6 सरिया दिया है,इसमे हमारी गलती नहीं है,ठेकेदार ही जैसा बोला वैसा किया,अब किया कर सकते है सर?कोई समस्या तो नहीं होगा न?
Floor kitne h
@@myengineeringsupport अभी फिलहाल एक ही फ्लोर बना हुआ है,लेकिन दो फ्लोर तक ही रहेगा सर
Tu Mala Manjil ka chad main ppc cement aur local Sariya Dene Se Kuch problem Hoga Kya
No
Same 2story k liye column aur foundation par bhi video banao
Aaj 1 bje ayegi
Thank u sir
2 storey means G+1 haina
Mera column to colum distance 20 feet h .
Beam ka steel kitna rakhna chahiye
Consultant with structure engineer
Sir plinth beam de raha hoon DPC dena jaruri hain
Vaise to dono dena sahi rehta hai par kaam chal jayega plinth beam se bhi
दीवार 10इंच हो तो पीलाड़ 9 इंची होगा
Ok
Tie Beam Niche Guard Wall ka height kitna dena hoga ?
Minimum 3 feet
Sir kya hum G+3 ke liye beam size 9/12 aur ush m sariya 12 mm ke 6 dia use kr skte h aur column to column ka distance 14 ft h
Yes you can
Plinth beam ko 3feet me rakhenge to DPC ko kitne me denge
Ek Mala Manjil Mein 16 culam hai but 2 manjit main culam nahi denge Tu chalega..plz help
No
3 manjila ka plinth beam ka reinforcement batayen please
Sir mani ek ghar main 16 feet column distance main plinth beam ka reinforcement mai 12 mm top main or bottom main 16 mm ka bar dia hai or 12 mm ka extra support in column corneer main dia hai,,, kya ye G+1 building k liye sahi hai
Perfect
Sir total 4 bars dia hai 2@12 and 2@16 kya or vi dena hai?
Sir plinth beam mein crank bar provide karte hai ya nhi?
junction pe bar kaise provide karne h wo to bta dete
5 manjil k makan me ground beam ka sariya detail batayiye pls
Noted
Sir hame naksha banwana hai 32*32east facing
Contact me on 9996656740
Lilith bim ke upar 5 fit ke bad bim dena jaruri hai
No
Chhat ki dhalai ke liye
Please more than 16' feet Ka steel details Ka videos banaye...yeah video toh bohat hai youtube par... mujhe more than 16' feet ke hona
Noted
Four manjila Ghar ki plinth beam Ka reinforcement details kiya hoga please batana.
Video already on channel pls check
Aapne extra bar ke bare nhi btaya is video me. Extra bar nhi dena h kya ??? Pls reply. Agr extra bar dena h to size kya dena h .Pls reply. Mera ghr Ka plinth beam bnane vala h 1 ya 2 din me.
ua-cam.com/video/wLwEe1wqNnI/v-deo.html
Watch it
Is video me length of extra nhi btaya gya h..kis jgh dena dena h ?? Residential 2 story building ke lie extra bar dena compulsory h ya optional h??pls reply
For any query
😀😀Follow this link to join my Telegram group:
Join this Group, Special for civil Engineers & Architects.
t.me/joinchat/Vig1gIW41fUtqIfW
How much cover as per IS code for column, beam and slab?
For column - 40mm
For beam - 25mm
For slab - 15 to 20mm
Itna km se km hona chahiye
What is cover
Mujhe 25*77 me ground flore sirf hall rakhna hai to plinth aur top BIM me kitne mm ka sariya de
Minimum 12mm
Simple ground floor Banane Mein Kitna kharch aaega sar
Depending on area
Sir what should be the beam size for 20 feet column to column distance
Consult with structural engineer for design
sir plinth beam distance 15 fit used 4 rod (16mm top & 12mm bottom ) 2 floor k liye sehi he
Enough
Bottom me 16mm or top me 12mm rakhna sahi hai,, agar beam cantilever nhi hai to
30x40 plot size I am giving 6 bars .
4 nos 12 mm
2 nos 10 mm
Beam size 9 inches by 12 inches
Good
G+2 Ghar me colom me 12 mm steel 4 pic dia hun sir galat Kia hun kya sir plz reply me?
No thik h
Aap Gujarati legvej malacan moklo
15 फिट दुरी मे कालम व रुफ बिम मे सलिया व कालम की साईज क्या दे
Column size kitna....
9x12
SIR GROUND FLOOR.+2 KA VIDEO BEJNA
Already uploaded
Plinth beam mein 10dayi6pis theek hai jindal
No
hi
Kuchh log 10mm ka sariya plinth beam me dal deta hai to use koi dikkat hai।
Sir hamara toh 6mm ring 5cm center too center de diya
Only g+1 building ke liye problem hogi kiya sir please rply
Bilkul galat kiya yaar
@@myengineeringsupport dikkat hogi kiya ??
Nhi spacing 2inch hai to koi problem nhi hai
@@myengineeringsupport thanks sir... Spacing 4cm hain
Mera Foundation ho gaya
Ab main Foundation ke upar 8mm laga du kiya sir ?
Han sabhi stirrups dia 8 ka kro beam ho ya column