Megger MIT515, MIT525 & MIT1025 Insulation Testers - Product Demo

Поділитися
Вставка
  • Опубліковано 18 гру 2024

КОМЕНТАРІ • 16

  • @kaboom2800
    @kaboom2800 3 роки тому

    The Manual says black leads (-) must be connected to Conductor to be tested, red (+) leads must be connected to armour of the cable. We’ve been doing it wrong here for ages. Red on the conductor and black on the armour.

    • @Alexlazenby777
      @Alexlazenby777 3 роки тому

      Our tester doesn’t stay at 5000v, just tests at like 45v any idea how to sort this?

  • @mohammedyacoub2049
    @mohammedyacoub2049 10 місяців тому

    Is there a way for the device to make pep sound when the 10min test finishes?

  • @TawandaMahofa
    @TawandaMahofa 8 років тому +4

    GUYS MY MEGGER MIT 525 IS PUSHING VOLTAGE UP TO 7V ONLY HOW DO I RESET IT

    • @sayedrabi3311
      @sayedrabi3311 6 місяців тому

      I have same problem, did you fixed it

  • @cemorhun6414
    @cemorhun6414 3 роки тому

    which current do these kind devices apply ? alternative or direct current?? thanks.

  • @hassanlabran751
    @hassanlabran751 2 роки тому

    What if the red probe is connected to the copper core and the black probe to the armour

  • @moseschansa5666
    @moseschansa5666 Рік тому

    What can I do when I switch on the Megger then Error 10 appears on the Screen??

    • @PowerpointIeIre
      @PowerpointIeIre Рік тому

      Hi Moses, it sounds like your meter will have to be sent back to Megger for internal investigation. You need to contact whoever supplied you with the unit or your local Megger agent to arrange this.

    • @sayedrabi3311
      @sayedrabi3311 6 місяців тому

      Did you fixed it

  • @bennysihombing8540
    @bennysihombing8540 2 роки тому

    Hello sir can you help me?
    My megger type is MT1025 and now the megger stil showing the err10 code
    How to repair the eror in my megger? Thank you

    • @PowerpointIeIre
      @PowerpointIeIre 2 роки тому

      Hi Benny, unfortunately this error code can only be diagnosed and repaired by Megger themselves. You will need to return the unit to your local Megger agent for them to send it back to Megger for analysis and repair.

    • @sayedrabi3311
      @sayedrabi3311 6 місяців тому

      What did you do

  • @Abo_Moussa
    @Abo_Moussa Рік тому

    5:47

  • @moseschansa5666
    @moseschansa5666 Рік тому

    Ensure that the test cables are longer.....

  • @eng.omareyadaljorani9954
    @eng.omareyadaljorani9954 3 роки тому

    Excuse me Sir, l have megger MIT515 ,and During the test electricalPowerTransformer , this phrase appeared to me: br.d