Rebaring work in RCC Columns & Wall by Fischer Chemical method.

Поділитися
Вставка
  • Опубліковано 4 гру 2019
  • Rebaring work in RCC Columns & Wall by Fischer Chemical method. #rbsingh #civil #youtube #rebaringinrcccolumsandwall #rebaring #test #procedures #rcc #concrete

КОМЕНТАРІ • 179

  • @pradeepkumaryadav3859
    @pradeepkumaryadav3859 3 роки тому +3

    Thank you sooo much for explaining it in a very simple way with complete details about it without leaving a single point

  • @JyotiSingh-pg8xy
    @JyotiSingh-pg8xy 2 роки тому +4

    Nice video sir from Tanzania, I am civil engineer really good information..

  • @shaikshakarimulla1367
    @shaikshakarimulla1367 3 роки тому +2

    Excellent dear amazing explained

  • @pradipbhattacharjee448
    @pradipbhattacharjee448 Рік тому +1

    Very innovative idea..thanks 👌

  • @Rj14facts826
    @Rj14facts826 4 роки тому +1

    Thanks for tell about depth relation with dia. Of steel bar

  • @deshiupaysetaiyar6537
    @deshiupaysetaiyar6537 2 роки тому

    Very good information sir ji

  • @karmjeet3688
    @karmjeet3688 2 роки тому +1

    Very good job sir

  • @harshamallampalli7398
    @harshamallampalli7398 3 роки тому +7

    Good Content sir. But a small correction. Just like for construction of a building where structural analysis is necessary, it is equally necessary to design post installed rebar applications like these following Eurocode 2 refer Technical Report 023. Just FYI. 10times the diameter is not the right measure of depth.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 роки тому +4

      Thank you brother for good suggestion ,, In the next video, reference was made by checking the video above what you have given .

  • @satyanarayanroy8294
    @satyanarayanroy8294 2 роки тому

    Excellent for rebar video

  • @khushbuinfracon9864
    @khushbuinfracon9864 4 роки тому

    Very nice 👌👌

  • @dhammadeepdevke2334
    @dhammadeepdevke2334 3 роки тому

    Long life chalega kya... Coz load will only on rebar ans concrete is just joint another column/beam

  • @agaaz1776
    @agaaz1776 3 роки тому

    Nice Sirji.

  • @giriprasadbammidi2798
    @giriprasadbammidi2798 2 роки тому

    Can we do it for column rod, whenever there is no possibility of clink.

  • @satishdungariya8262
    @satishdungariya8262 3 роки тому

    Very good video sir

  • @manojkumargupta9805
    @manojkumargupta9805 3 роки тому

    Very nice 👌👍

  • @indersaini513
    @indersaini513 3 роки тому +1

    Mostly max. Dia bar used in bottom layer. As u told 25 dia bar taking top layer and 20 dia bar in bottom.

  • @manibhushansingh4489
    @manibhushansingh4489 2 місяці тому

    Very nice

  • @foodjkvlog1
    @foodjkvlog1 4 роки тому

    Sir Mera gharr 3 manjil bana hua h but ground floor waale kamre m pillar nhi h 9" ki wall h or ab deewar m crack aane lage h load ki vajah se...second floor prr Piller beam dono h

  • @arshadgholam2799
    @arshadgholam2799 4 роки тому

    Yeh staircase ke midlanding ka steel missing tha shayed? Yeh kis project ka hai aur kaun si company kaam kar rahi hai? Dekhne mein to barha project lag raha hai.

  • @amitkumarlife5360
    @amitkumarlife5360 4 роки тому

    Good video

  • @anilsingh8430
    @anilsingh8430 3 роки тому

    Very nice video

  • @nanamarkad7832
    @nanamarkad7832 11 місяців тому

    Can any one sugest best chemicals brand for rebaring for 18 inch cantilever beam..(this beam will also carry brick wall load)

  • @11sudipdutta
    @11sudipdutta 4 роки тому

    Very good

  • @hareswarhajong7533
    @hareswarhajong7533 3 роки тому

    Good method

  • @diksharathore2560
    @diksharathore2560 Рік тому

    Sir but humara pillar ki saria to h but wo galat 9 inch doori par h to uska load chat par aayiga to rebearing kr skte h

  • @raghuveersingkumre7539
    @raghuveersingkumre7539 7 місяців тому

    Slab ke liye beam bhi joint kar sakte hai. purane colum se please batayega sir

  • @rbsinghcivilengineeringaca6777
    @rbsinghcivilengineeringaca6777  4 роки тому +2

    🙏🙏🙏🙏🙏

  • @civildaddy6258
    @civildaddy6258 7 місяців тому

    Thank You Sir

  • @radhe3699
    @radhe3699 Рік тому

    Sir can we done rebaring in brick structure of 12 inches wall

  • @deshiupaysetaiyar6537
    @deshiupaysetaiyar6537 2 роки тому

    Good👍👍

  • @amitkumarlife5360
    @amitkumarlife5360 4 роки тому

    Nice

  • @pradeepverma6686
    @pradeepverma6686 Рік тому

    Kitne ghante baad concrete kr skte hai

  • @prajwalsrinivas1842
    @prajwalsrinivas1842 3 роки тому +3

    Hi sir,
    Can i extend 2.5 feet rcc slab of ground floor length 30 feet just for passage of 1st floor...no loads no wall just slab for passage..
    1st floor outer walls will be on old slab itsef...

    • @PranoyRoy1991
      @PranoyRoy1991 2 роки тому

      Yes why not.install 4columns for load distribution

  • @bikashchandrabauri6139
    @bikashchandrabauri6139 10 місяців тому

    Sir apka video main Bhahot kuch sikhne ko milta hai
    Very good sir
    Sir rebaring is code kaya hai?

  • @alibasu508
    @alibasu508 4 роки тому

    Sir where is this site?

  • @asjadkhan7258
    @asjadkhan7258 3 роки тому

    Column mera side may crck hai us ke liye koi achcha atreeqa batao

  • @doctorvimalkatarmal4704
    @doctorvimalkatarmal4704 4 роки тому

    good work👍

  • @planningteam2666
    @planningteam2666 4 роки тому

    Man gye dada

  • @spectrovision7466
    @spectrovision7466 Рік тому

    By doing this you are missing 2 valid points .
    1. The joint doesn't become RCC for beam . It's only steel there at beam-wall interface to take care of the load .
    2. The beam doesn't get any bearing on wall .

  • @busylife1235
    @busylife1235 2 роки тому

    Sir fr that which IS CODE is followed?

  • @keshavkumar390
    @keshavkumar390 Рік тому

    Good idia

  • @ADILKHAN-gh4xg
    @ADILKHAN-gh4xg 3 роки тому

    🙏

  • @srabansingh6655
    @srabansingh6655 4 роки тому

    Sir ishka load test kaise karege...

  • @traininginengineering6398
    @traininginengineering6398 2 роки тому +1

    Good

  • @nanamarkad7832
    @nanamarkad7832 11 місяців тому

    For taluka malshiras dist solapur state maharashtra ke liye koi rebar ke liye hai kya

  • @bhupenparmar1523
    @bhupenparmar1523 2 роки тому +1

    Nice sir

  • @hafeezrehman3920
    @hafeezrehman3920 4 роки тому

    Sir ap India mn e job krty hn?

  • @anuragsarkar8842
    @anuragsarkar8842 3 роки тому +1

    If people start doing rebaring this way, then believe no structure will be safe. It’s absolutely disaster how he is fixing those reinforcements, he is literally hammering them.

  • @Singh.RichyRich
    @Singh.RichyRich 3 роки тому +3

    Sir Ji, Chemical to theek hai, Lekin hole 🕳 for 2/3 full kiya Jata hai Pehle. Jaise aapne kiya hai woh itna nahi bhra. Main bhi yehi kaam karta hoon Australia mein. Hum Hilti Use karte hain. Cleaning process bhi aapki thodi aur safai se honi chahiye thi. Brush use karke, fir blower, fir brush fir blower. Chemical anchoring is a serious business and your bond is as good as your hole cleaning. Wear ear muffs and gloves for safety reasons. Be safe and keep up the good work.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 роки тому +1

      Very good dear , Next video me aap ki baato ka dhyan diya jaayega..
      Thank you for good suggestion..

    • @hemalpatels2016
      @hemalpatels2016 2 роки тому

      Aur bhi ek bat hai ki 20 dia rod k liye drill bit bhi 20 ka hi use kiya, kya ye sahi hai??
      20 dia ka rod rebaring k liye bit kitne mm ka use karna chahiye??

    • @digantdubey8863
      @digantdubey8863 2 роки тому

      @@hemalpatels2016 20mm ke rebarring ke liye 24 mm ki bit use honi chahiye

    • @nanamarkad7832
      @nanamarkad7832 11 місяців тому

      Can any one sugest best chemicals brand for rebaring for 18 inch cantilever beam..(this beam will also carry brick wall load)

    • @Singh.RichyRich
      @Singh.RichyRich 11 місяців тому

      @@nanamarkad7832 Hilti has quite good reputation. Better off consulting them before use.

  • @surajitdas-qx5vb
    @surajitdas-qx5vb 2 роки тому

    Is chemical ko hum log bhi banate hai. Humara company ka nam VIBGYOR INC(Kolkata).

  • @kaushiksharmah1483
    @kaushiksharmah1483 Рік тому

    Good Explanation!
    But its a layman s way its done, but Rebaring is a very technical topic!
    Any connection done needs to be designed as for EC2! 10D is death trap, plz avoid!

  • @papiamondal9839
    @papiamondal9839 3 роки тому

    Aisa chidki opar Kalam kia jasakta ha, kyoki chad ki rod sob katahoaaha,

  • @6070avm
    @6070avm 2 роки тому

    How many inches of steel should be inserted inside the concrete

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 роки тому +1

      Minimum 10 dia of Steel.

    • @6070avm
      @6070avm 2 роки тому

      concrete insert steel length

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 роки тому +2

      @@6070avm minimum steel inserted in the concrete 10 X dia of Steel,
      Suppose that steel used in the columns 12mm dia , minimum requirements of steel insert of concrete 120 mm .
      maybe clear this doubt sir ji.. 👍👍

    • @6070avm
      @6070avm 2 роки тому +1

      @@rbsinghcivilengineeringaca6777 Thank you sir

    • @spectrovision7466
      @spectrovision7466 Рік тому

      @@rbsinghcivilengineeringaca6777 , he is asking how many inches ...gaddha mistri ban'na chahiye .

  • @chanderpaswan1305
    @chanderpaswan1305 Рік тому

    Sir conse hammer se plinth bim ,me hole ho jayega, mere pas tiger ka hammer h, but usse hole ni ho pa rha, pls help me.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  Рік тому +1

      Hilti drilling machine ya Boss drilling machine ka use Karo brother, sath mein steel ki marking jarur kare ta ki ham side me ashani se drilling kar sake.

    • @chanderpaswan1305
      @chanderpaswan1305 Рік тому +1

      @@rbsinghcivilengineeringaca6777 ji , thankyou 🙏 so much sir,sir rebarring karna h, plinth Bim me, new constitution h, bathroom k liye , kya chemical use karna compulsory h, pls help me

  • @vickarttoyou9876
    @vickarttoyou9876 4 роки тому

    iske baad iski testing bhi hotti h ya nhi???

  • @ayubshaikh96
    @ayubshaikh96 3 роки тому

    thank you for video but aap kanjuse karna sikha re ho chemical ko hole ke depth me minimum 70 % fill karna hota hai ta steel andar jane k baad 100% chemical ho

  • @arpitajain6327
    @arpitajain6327 2 роки тому

    What are Service charges per hole. Any contact for Indore.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  2 роки тому

      Mr. Kasi ram ji +919561425493 , Already indore madhya pradesh , mein hi hai aap is person se contact karke rate faur chemical ke bare mein pata kar sakte 👍👍

  • @arbazinmandar7743
    @arbazinmandar7743 3 роки тому +1

    ऐक बॉटल मे कितने राड होते 12mm के
    6 ईन्च अनदर

    • @s.bproject1406
      @s.bproject1406 2 роки тому

      Apko krane h kya sir

    • @s.bproject1406
      @s.bproject1406 2 роки тому

      Apko krane h kya sir

    • @chanderpaswan1305
      @chanderpaswan1305 Рік тому

      ​@@s.bproject1406 sir plinth Bim me hole ni ho pa rha tiger hammer se, kya solution hai, pls help me

  • @SaurabhKumar-uf9bj
    @SaurabhKumar-uf9bj 2 роки тому

    Lekin sir cmcl lagane k bad gun rakhne par sukh jata h

  • @kiranbhatia2554
    @kiranbhatia2554 2 роки тому

    Aise karne bricks ka weight sahan kar lega?

  • @cabp9
    @cabp9 4 роки тому +4

    WRONG GROUTING IS CARRIED OUT. FISCHER MATERIAL IS NOT ADEQUATE.

    • @jvjv6332
      @jvjv6332 Рік тому

      Why sir?

    • @shahinahmad9695
      @shahinahmad9695 Рік тому

      @@jvjv6332This material is not epoxy based. It is vinyl based. Epoxy is better and appropriate for such job.

    • @pradeepshriyanvlogs
      @pradeepshriyanvlogs Рік тому

      better to use forsroc Lockfix,,Sastha and Majbooti hai... Baaki sub befaaltu ..

  • @suryaraj1831
    @suryaraj1831 3 роки тому

    How can we calculate rebar drill debth for formula

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 роки тому +1

      10D is taken and which is important in depth of hole , So that my steel , Dia is 20 or 25mm, Hole depth = 25×10 = 250 mm & 20×10 = 200 mm as per IS code required for rebaring work

    • @thiruvuvignesh4203
      @thiruvuvignesh4203 3 роки тому

      @@rbsinghcivilengineeringaca6777
      Sir kindly tell us IS CODE no

    • @spectrovision7466
      @spectrovision7466 Рік тому

      Class 5 me join karo . Multiplication sikho useless log .

  • @snkshorts4626
    @snkshorts4626 Рік тому

    25 Mm ke rod ko fix karne ke liye to 28 mm ke bit se drill karna chahiye na hammer marne se kamjor hojata hai aur above 16 mm ke rod ke liye fisher ka chemical bahut bekar hai hilti RE 500 hona chahiye

  • @Amitkumar-vb4mq
    @Amitkumar-vb4mq 4 роки тому

    Chemical Ka kya nam he batiye please

  • @aamirsaifi1470
    @aamirsaifi1470 3 роки тому

    Is chemical ka name aur price kya hai plz bataye🙂

  • @Tej_bharadwaj
    @Tej_bharadwaj 2 роки тому

    Coloum ka v same process hota h?

  • @Ankeshkumar-jl5tk
    @Ankeshkumar-jl5tk Рік тому

    Chemical ka naam kya hai

  • @vnxndhjf3648
    @vnxndhjf3648 3 роки тому

    bottle se pahle chemical nikale Nahin sar

  • @angadyadav1351
    @angadyadav1351 3 роки тому

    R e Wall ka full form rain force ha kya sir ji

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 роки тому +2

      दोस्त , री- वायरिंग का मतलब होता है किसी भी जगह में दोबारा स्टील बार को डालना..

    • @s.bproject1406
      @s.bproject1406 2 роки тому

      Returning wall

  • @akilanconstructions1196
    @akilanconstructions1196 2 роки тому

    Hello sir the chemical name

  • @pritamchakraborty3696
    @pritamchakraborty3696 4 роки тому +3

    This is an absolutely wrong method of post installed rebar grouting.
    First of all Rebar grouting methods and principles are defined by European Technical Association and not IS. Also there is no concept of 10XD. That is absolutely wrong.
    The drilled hole diameter for every rebar size is mentioned by ETA.
    The cleaning of holes need a brush cleaning along with blower.
    The way the chemical is injected is wrong. You should use a plug for that.
    You should always understand that any engineering application should not be causally taken into account.

    • @jskhani
      @jskhani 3 роки тому +1

      Yes you are right. This is all poor work.

  • @deepaksingh-rb5tj
    @deepaksingh-rb5tj Рік тому

    Sir iska IS Code Kya ha

  • @shivshaktienterprises7183
    @shivshaktienterprises7183 4 роки тому +1

    ये HILTI machin nahi

  • @silvinremedios7347
    @silvinremedios7347 6 місяців тому

    😅❤ 0:37

  • @shanuahmad9647
    @shanuahmad9647 3 роки тому +1

    Sir kisi slab pr M25 dalni thi or galti se M20 dal gyi ho to fir solution kya hoga plz reply. M ye question ka answer kafi time se khoj rha hun plz solution provide kren.🙏

  • @angadyadav1351
    @angadyadav1351 3 роки тому

    Rw wall ka full form kya hi sir ji

  • @Veku0007
    @Veku0007 3 роки тому

    Sir muje ya chamical chahiye Kha milega

  • @sandeerock2470
    @sandeerock2470 4 роки тому

    Kya ye belivebal h

  • @vinodkumarpatel699
    @vinodkumarpatel699 3 роки тому

    प्लीज इसका रीवा रिंग डॉक्टर फिशर का रेट बताइए कितना मिलता है

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 роки тому

      Dear ismein bahut Sare product aate Hain aapko kis kam ke liye chahie, yadi crack repair ke liye aap baat kar rahe hain to near about 500 rs to 700 Rs ke near about per kg padega.

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 роки тому

      Aur yadi aap bada packet Lete Hain to is se kam rate padega.

  • @jayeshlakum7956
    @jayeshlakum7956 4 роки тому

    Bhai chemical itna daalo ki road daal ne ke baad chemical bahar aaye

    • @jskhani
      @jskhani 3 роки тому

      Correct,it’s a poor work

  • @deshiupaysetaiyar6537
    @deshiupaysetaiyar6537 2 роки тому

    Very good work, Sir aap ka mobile number mil saktaa hai kya..

  • @prahladkumar2269
    @prahladkumar2269 Рік тому

    Name bataeye na

  • @Topnotchindustrial
    @Topnotchindustrial Рік тому

    Machine hilti nhi hai bro... Koi aur company hai

  • @chandkazi8664
    @chandkazi8664 3 місяці тому

    सही से एक्सप्लेन नहीं किया

  • @Youbegaming2010
    @Youbegaming2010 11 місяців тому

    Ma

  • @lachhirajak9198
    @lachhirajak9198 2 роки тому

    Rebaring aise nahin hoti bhai

  • @mohammedshaikh6533
    @mohammedshaikh6533 4 роки тому

    Yeh chemical kha milenga?

  • @jskhani
    @jskhani 3 роки тому

    Contact me for Pull Out test

  • @sattaking8530
    @sattaking8530 3 роки тому

    Kaam करना आता नहीं है और लोगो को बता रहे है की ऐसे होती है री ribarig कितना ml केमिकल डालता है होल मे ऐसे होती है ribarig

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 роки тому

      Very good dear.. please send the correct methodology for this work...

    • @divitpatel3757
      @divitpatel3757 3 роки тому

      @@rbsinghcivilengineeringaca6777
      Ye video dekh lo🤭🤭
      ua-cam.com/video/GjP2dGyb4as/v-deo.html

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 роки тому +1

      dost hamare video aur is video mein jyada antar Nahin hai main bhi ho Sakta hai aapane Sahi tarike se video ko Dekha Nahi hai..

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  3 роки тому

      दोस्त हो सकता है आपको हमारा वीडियो अच्छा ना लगा हो और जो आपने भेजा है और जो हमारा वीडियो है वह लगभग 90% एक जैसा है कृपया और अधिक जानकारी के लिए आप हमारा वीडियो पूरा देखिए 🙏🙏

  • @IsrarKhan-ok4nt
    @IsrarKhan-ok4nt Рік тому

    Firstly, it is not rewiring it is rebarbing, secondly your method of grouting is wrong, chemical is poured inside the hall at once and it should fill and come out and thirdly your grouting chemical itself is wrong.

  • @thedemocratic_indian
    @thedemocratic_indian Рік тому

    Aap re wiring kyu bol rahe ho

  • @sachinnppl293
    @sachinnppl293 4 роки тому

    Ye bilkul fail method hai
    Bar ko thoka nahi jata

    • @rbsinghcivilengineeringaca6777
      @rbsinghcivilengineeringaca6777  4 роки тому

      Sir ji sahi method ko batao Bhai Kya hai... Civil engineering ka koi 1 methods nahi hota hai ..bahut sari method hote hai..

    • @pritamchakraborty3696
      @pritamchakraborty3696 4 роки тому

      You are absolutely right. Rebar ko kabhi Thoka nahi jata.

    • @pritamchakraborty3696
      @pritamchakraborty3696 4 роки тому +2

      @@rbsinghcivilengineeringaca6777 Sir aap European Organization for Technical Approvals ka report TR023 Assessment of Post-installed reinforcing bar connections padh lijiye. Waha pe likha hua hain. Ya phir www.hilti.in pe padh lijiye.

  • @chappaseetamnaidu5744
    @chappaseetamnaidu5744 4 роки тому

    Very good

  • @srabansingh6655
    @srabansingh6655 4 роки тому

    Nice