What terminals are used in the controller and the actual settings for combining several controllers into one (if the system operates autonomously, that is, without connecting to a local network)? Perhaps UP-link RS-485... The dip switch is used to set the device number, by default it is 0
Hi there, I followed all the steps in video which is very easy and well made (thanks) the problem I encountered is when I scan the fob to add a user I can hear the beep but nothing happens. Please help
Hello. Any idea why card reader (DS-K1107A), connected to a DS-K2602-G controller will not read HID Proximity 1346 ProxKey III H10301 key fobs? The reader does not even detect the key fob, does not beep. The reader is set to Wiegand 26 and is able to register other card types. Hikvision tech support were unable to figure it out. Thank you.
Hi Oliver, Thanks for Great video. Would this system work with a pulse door lock motor? Including a break glass to allow the door to be open when the power drops out? Many Thanks Liam
Here a clue, at 1118 you show resistors then at 1128 you show VarResistors, two different things. Also thos should ne at the lock end so the fly wheel effect gets absorbed into the coil of the device not the contact of the controller end.
Hello, Thank you for the interaction, the resistors shown at out of the box and also in the wiring example are actually both types Piezoresistors. Piezoresistors are designed to protect the relay in the controller as well as to prevent maglock burn-in when a change in resistance when it is strained. This is demonstrated as bridging across the Lock+ and Lock- which wires to V+ and V- on the maglock and not across the relay. This is as per the manufacture CE approved guides. Whether these are wired on the maglock, halfway down the V+ and V- cable or at the controller end does not make a difference, so long as this is before the relay, in which case this is.
Hi, You will either need 2X DS-K2604 and 1x DS-K2602. Alternativley, you could opt for the Ultra Series controller, DS-K2704 with 3X 2 door modules DS-K2M002X ua-cam.com/video/hh0-1RGRW4Y/v-deo.htmlsi=L2iuQSOfrZjX8oyi
Hello, The 2700 series controller allows you to manage upto 128 doors from a single controller when using with the 2 door modules. ua-cam.com/video/hh0-1RGRW4Y/v-deo.htmlsi=7tEou0SA-Uw_8z6h
@@yasirmydeen7845 Hi, the fingerprint reader takes a fingerprint read, and then uploads a card number to the controller to open the door. Due to the fact it requires a half-duplex protocol, this needs to be RS485 wiring which is reserved for Hikvision readers only.
Really found this video to be incredibly helpful! Looking forward to more content like this in the future.
Glad it was helpful!
Very good. How do you add a user PIN instead of a card?
Same question here!
What terminals are used in the controller and the actual settings for combining several controllers into one (if the system operates autonomously, that is, without connecting to a local network)? Perhaps UP-link RS-485...
The dip switch is used to set the device number, by default it is 0
Hi there,
I followed all the steps in video which is very easy and well made (thanks) the problem I encountered is when I scan the fob to add a user I can hear the beep but nothing happens.
Please help
Hi there,
Any instructions about powering the panel?
Thx
Hello. When I try to add a device, I get this error, hcnetsdk.dll 7.Can you help me?Thanks.
May I ask if you know - can a Paradox Reader work with Hikvision Controller?
Yes, you can! You would need to use Weigand wiring protocol for any third-party reader into the Hikvision Controller.
cool Video. i have a question: is it possible to add a DS-KV9503-WBE1 with DS-K2604T? How can i do it?
I also want to know if the DS K2604T is a reader in reader out ( I don't want to use exit button)
Hi, the DS-K2604 is a 4 door controller that supports 8 readers via RS485 for read in and read out.
Hello.
Any idea why card reader (DS-K1107A), connected to a DS-K2602-G controller will not read HID Proximity 1346 ProxKey III H10301 key fobs?
The reader does not even detect the key fob, does not beep.
The reader is set to Wiegand 26 and is able to register other card types.
Hikvision tech support were unable to figure it out.
Thank you.
i am getting crazy everthinh ok , but on realtime monitoring it says " Card No. Does Not Exist and invalid "
Can you tell me how to change the lock types? magnetic and non-magnetic ones are installed - NO and NC
Hi, In the controller, underneith each white relay, there is a jumper.
Move the jumper over to change between NC and NO.
Great video
Very useful ❤
Thanks 😊
Hi Oliver, Thanks for Great video. Would this system work with a pulse door lock motor? Including a break glass to allow the door to be open when the power drops out? Many Thanks Liam
Yes, absolutely
Here a clue, at 1118 you show resistors then at 1128 you show VarResistors, two different things. Also thos should ne at the lock end so the fly wheel effect gets absorbed into the coil of the device not the contact of the controller end.
Hello,
Thank you for the interaction, the resistors shown at out of the box and also in the wiring example are actually both types Piezoresistors.
Piezoresistors are designed to protect the relay in the controller as well as to prevent maglock burn-in when a change in resistance when it is strained.
This is demonstrated as bridging across the Lock+ and Lock- which wires to V+ and V- on the maglock and not across the relay. This is as per the manufacture CE approved guides. Whether these are wired on the maglock, halfway down the V+ and V- cable or at the controller end does not make a difference, so long as this is before the relay, in which case this is.
Can you put one video for intercom using hikcentral professional
Thank you for your comment.
A video of this will be available soon
I have 10 doors which panel do I go for?
Hi, You will either need 2X DS-K2604 and 1x DS-K2602.
Alternativley, you could opt for the Ultra Series controller, DS-K2704 with 3X 2 door modules DS-K2M002X
ua-cam.com/video/hh0-1RGRW4Y/v-deo.htmlsi=L2iuQSOfrZjX8oyi
Is there a controller for more than 4 doors, say 40 doors like an office building
Hello,
The 2700 series controller allows you to manage upto 128 doors from a single controller when using with the 2 door modules.
ua-cam.com/video/hh0-1RGRW4Y/v-deo.htmlsi=7tEou0SA-Uw_8z6h
Hi there,
Is the software free when you buy the equipment?
Link where I can buy the system?
The software is free to download from the Hikvision website: www.hikvision.com/uk/support/download/software/hikcentral-access-control-v2-0-1/
Very nice
Thank you for your comment!
How to add third party finger terminal with hikvision 4 door controller
Can you share your mail id for technical support
@@yasirmydeen7845 Hi, the fingerprint reader takes a fingerprint read, and then uploads a card number to the controller to open the door. Due to the fact it requires a half-duplex protocol, this needs to be RS485 wiring which is reserved for Hikvision readers only.
tanks bro
Good
W
more bro