КОМЕНТАРІ • 94

  • @dustinholt7308
    @dustinholt7308 3 роки тому +7

    Moved it like a boss!!!

  • @Jaang29
    @Jaang29 8 місяців тому

    Thank you , and hello from Naples , Fl and Miami , FL , merry Christmas 12-06-23

  • @jasonkane6879
    @jasonkane6879 3 роки тому +7

    1:15 Always use two people to move the unit......"Hold my beer!"

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому +1

      Just remember, with enough anger and caffeine, anything is possible!

  • @kristinayamaguchi5504
    @kristinayamaguchi5504 4 роки тому +4

    Daamn you got some muscle! Nice video too

  • @dtm8073
    @dtm8073 3 роки тому +1

    I used to be young and stupid and thought I could lift everything and now my back is fucked! Ask for help with heavy things, you might not notice now but when you get older you'll notice. Not trying to piss in your corn flakes just looking out for you! Great video!!!

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому

      I appreciate it man, definitely one of those scenarios where I got tired of waiting and just went for it!

  • @ketotrucker3528
    @ketotrucker3528 2 роки тому

    You just manhandled that compressor outside! LOL. Wow

  • @CycleNorthCrew
    @CycleNorthCrew 4 роки тому +1

    #labcoatlarry out here getting gains! 💪💪💪

  • @DeeNo909
    @DeeNo909 3 роки тому +1

    WTF BRO SO YOU JUST GOING TO PICK THAT COMPRESSOR UP BY YOURSELF DAMNNNNNNN. I HAD TO CALL SOME HELP HAHAHA.

  • @gittyupalice96
    @gittyupalice96 3 роки тому +3

    that dudes a TANK! guess it takes a tank to move a tank now that I think about it, pretty sure its in the U.S. Army hand book.

  • @MrSteppingstone888
    @MrSteppingstone888 3 роки тому +2

    Two wheel hand truck is the ticket not your back, when we get older that work ethic's will catch up with you. Take it from a retired commercial plumber // 👍

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому +1

      I appreciate the advise, and moving it that way once was enough for me!

    • @MrSteppingstone888
      @MrSteppingstone888 3 роки тому +1

      @@ThrownSparksGarage Your welcome, always think it thru . I seen plenty men early on cut in half from a disability with bad backs because of not thinking it thru.
      heck just being a tradesmen till you retire could wear you down thin, I barely made it and I was careful but worked very very hard.
      I have the same compressor I pamper mine I just put in the Royal purple
      supposedly never breaks down
      www.amazon.com/gp/product/B000BRTCIS/ref=ppx_od_dt_b_asin_title_s00?ie=UTF8&psc=1

  • @alejandrotoribio3338
    @alejandrotoribio3338 7 місяців тому

    Gracias

  • @christopherowens2635
    @christopherowens2635 Рік тому +1

    is it true its a single stage but operates like dual stage? false advertisement?

    • @ThrownSparksGarage
      @ThrownSparksGarage  Рік тому

      I can’t save for sure since I’ve never used dual stage, but I don’t have any complaints so far.

  • @michaelbrown9337
    @michaelbrown9337 2 роки тому

    20a double pole breaker with 12/3 SO cord also a 20a male cord cap.

  • @ranchitosantos5165
    @ranchitosantos5165 Рік тому

    Did he just carry that thing???

  • @user-hf4nv6fb5r
    @user-hf4nv6fb5r 5 місяців тому

    Mine turns off after like a minute and won’t turn on anymore until I reset it does that over and over

  • @philvincent5589
    @philvincent5589 Місяць тому

    If mine trips the breaker every time I turn it on what do you think the issue is?

    • @ThrownSparksGarage
      @ThrownSparksGarage  Місяць тому

      I would double check the owners manual to make sure you have the right sized breaker for the air compressor. If that’s not the problem, double check you aren’t shorting anything in the on/off switch with your wiring.

  • @alexdelaney3806
    @alexdelaney3806 4 роки тому +2

    After watching you carry that I realize I'm in the wrong place lol. I do have a question, when you bought it did you keep it upright or can I lay it down in the back of my truck cuz I got a topper on it...

    • @ThrownSparksGarage
      @ThrownSparksGarage  4 роки тому +1

      Yeah that was definitely a time where I wish I had an extra set of hands to help lol. When I purchased it, it came on a pallet but I brought tools with me so I could remove it and then transported it the same way that you are planning on. I would recommend to bring something soft to rest it on and watch the orientation of the motor so it’s not putting to much stress on itself when you lay it down.

    • @bertgordon5114
      @bertgordon5114 2 роки тому +1

      @@ThrownSparksGarage My compressor came from the factory w/oil in it. I was told "do not lay it down"!

    • @ThrownSparksGarage
      @ThrownSparksGarage  2 роки тому

      Probably a good call, that was my only way to move it, I did leave it upright for 2 days before plugging it in

    • @miceskin
      @miceskin Рік тому

      @@bertgordon5114 I put it on its side and lost a shitton of oil, speaking of, which oil works for this and how do you check it?

    • @genek3961
      @genek3961 Рік тому

      @@ThrownSparksGarage p

  • @Carlos-pintorcarro
    @Carlos-pintorcarro 3 роки тому +2

    What size breaker did you use for the plug ? I have the husky red 60 gallon. It says 15 amp on the tank I’m just curious ! I’m about to do the same installation thanks for the video

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому +3

      So my breaker is a little oversized because I weld off of the same circuit. Which isn’t ideal for the compressor because it will allow it to draw more current before tripping but that’s the risk I’m taking with using a 30 amp breaker. If this is a dedicated circuit for the air compressor I would size it based on the recommendation for the air compressor.

    • @Carlos-pintorcarro
      @Carlos-pintorcarro 3 роки тому +1

      @@ThrownSparksGarage thank you for the reply today I ended up purchasing 10 thhn wire and 20 amp double pole breaker.

    • @josealequin2912
      @josealequin2912 Рік тому +1

      30amp the best

  • @avh6249
    @avh6249 4 роки тому +1

    Hi. Thanks for the video. I just bought that same compressor at Home Depot, but I can't find the 240 volt power connector, and I don't know where I can buy it ... I would appreciate a suggestion. Thank you.

    • @strungoutkid
      @strungoutkid 4 роки тому

      I too just bought one and watching this video to figure what I need to do.

    • @ThrownSparksGarage
      @ThrownSparksGarage  4 роки тому

      The power chord I used came off of an old welder that I scrapped. Your best bet would probably be to see if you have a local welding shop near ya and they could get you a properly sized power chord; or you may get lucky finding one at a local scrap yard. Hope this helps!

    • @avh6249
      @avh6249 4 роки тому +1

      Throw'n Sparks Garage OK, thank you so much.🤝

    • @israelrios40
      @israelrios40 3 роки тому

      @@strungoutkid where did you finally get the power cord from?

    • @israelrios40
      @israelrios40 3 роки тому

      Where did you get the power cord from?

  • @jorge220086
    @jorge220086 4 роки тому +1

    Hi friend could you share a photo of the internal connection of the motor to know how the cables go, I would appreciate it regards!

    • @ThrownSparksGarage
      @ThrownSparksGarage  4 роки тому +1

      It isn't letting me attach a image here. send me an email at thrownsparksgarage@gmail.com and I will send it to you!

  • @marco209lodi5
    @marco209lodi5 3 роки тому +1

    So how do you wire that? Is that 2 hots and ground on a 2 pole breaker or hot neutral and ground 1 pole breaker? I just bought this compressor

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому +1

      It’ll be a 2 pole breaker since it needs 240v input power and I used a power cable for an old welder to hook it up (green, white, and black).

    • @marco209lodi5
      @marco209lodi5 3 роки тому

      @@ThrownSparksGarage ok so you are using the white as a hot right. Thank you brother 🙏

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому

      @@marco209lodi5 Not 100% sure on that, I just followed the electrical diagram in the owners manual when wiring it up.

    • @gruponemesis
      @gruponemesis Рік тому

      ​@@ThrownSparksGarage he is correct...2 hots and a ground. Neutral is not always needed in 240v applications

  • @gruponemesis
    @gruponemesis Рік тому

    i saw that there was no neautral wire...just a ground and 2 hots (being that its 240v)
    You confused me when you said neutral lol
    thanks for the vid!

    • @ThrownSparksGarage
      @ThrownSparksGarage  Рік тому

      Yeah I get the 4 wire and 3 wire 240 plug terminology mixed up all the time lol

  • @pchevelle9653
    @pchevelle9653 Рік тому

    Did the pump need a break in?

    • @ThrownSparksGarage
      @ThrownSparksGarage  Рік тому

      Yes the pump did need a break in, I cant remember how long but I believe I mention it in the video.

  • @wenbinwu4141
    @wenbinwu4141 2 роки тому

    I brought husky 60 gallon 1-phase 175 PSI and used it just 2 times, it is not working now. The engaineer told us the switch has broken and always easy broken. So shall i exchange a new one or return it back?

    • @ThrownSparksGarage
      @ThrownSparksGarage  2 роки тому

      I would try to replace the switch itself as it shouldn't be to hard to remove. Would probably be easier than trying to take the whole machine back.

    • @wenbinwu4141
      @wenbinwu4141 2 роки тому

      @@ThrownSparksGarageYes, the machine is too heavy for me. How long have you use it? Have you exchanged a switch until now?

    • @ThrownSparksGarage
      @ThrownSparksGarage  2 роки тому

      I’ve had it for about 2 years, no issues yet. The switch itself has always seemed kinda junky to me but it hasn’t cause me any problems yet.

  • @TheSaulJohn
    @TheSaulJohn 3 роки тому

    Does this run on 120 or 240? I bought a display and have no instructions to it and am not educated in these things.

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому +1

      If you have the same model as me, it will need 240V input power.

  • @justinpierce4181
    @justinpierce4181 3 роки тому

    I have the same compressor and everything to go along with it except when I turned it on it did 2 things 1.was quiter 2. It won’t turn back on now any help is appreciated

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому

      I would double check the oil level and the switch on top, my switch was a little finicky at first and I needed to adjust how I wired it together. Also maybe check your breaker to ensure it’s sized properly and your input power as well.

  • @israelrios40
    @israelrios40 3 роки тому +1

    Where did you get the power cord?

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому

      The power chord I used came off of an old welder that I scrapped. Your best bet would be to look for a local scrap yard and maybe get lucky finding one, or by going to a local welding supplier. Hope this helps!

  • @bigmikez3128
    @bigmikez3128 3 роки тому

    So how has it held up! Great info on video to bro! I wanting to buy one for some painting projects I got coming up

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому +3

      It’s held up great so far, I’ve had a few days where I’ve really put the coals to it and it worked without any issues. The only thing I would recommend is replacing the drain valve that comes on it with something a little more reliable

  • @Nutflame55
    @Nutflame55 Рік тому

    so did you just plugged it in after that

    • @ThrownSparksGarage
      @ThrownSparksGarage  Рік тому

      No, I let it stand up for a full day since I had to lay it down to transport it.

    • @Nutflame55
      @Nutflame55 Рік тому

      @@ThrownSparksGarage I ment did u put a plug on it and plug it to the wall

    • @ThrownSparksGarage
      @ThrownSparksGarage  Рік тому +1

      Yes, standard 240V plug.

    • @Nutflame55
      @Nutflame55 Рік тому +1

      thank appreciate the response keep up the good work

  • @Marcoshernandez-jt6sq
    @Marcoshernandez-jt6sq 3 роки тому

    Que cable usaste boy a conectar uno igualito solo no se si es:12/2 ...o 14/2

    • @ThrownSparksGarage
      @ThrownSparksGarage  3 роки тому

      Being 240V, the manual says to use at least a 10 AWG wire size

  • @waysaunut
    @waysaunut 2 роки тому

    Haha, that looked heavy, just wondered if the oil was in it already or did you have to put it in, I ordered one but I wanted to lay it down when I go get it but if it has oil in it I won't be able to do that, Thanks for the info in advance.

    • @ThrownSparksGarage
      @ThrownSparksGarage  2 роки тому +1

      Mine came with the oil in it, I just rolled the dice a bit and stood it up for 24 hours before starting it since I had to lay mine down.

  • @bigeviltex7657
    @bigeviltex7657 2 роки тому

    i just got one of these compressors. My tank gets really hot. is that normal?

    • @ThrownSparksGarage
      @ThrownSparksGarage  2 роки тому

      Mine gets pretty hot as well. I haven’t had any issues with it because of this, but do have it separated so it doesn’t heat my garage up in the summer.

    • @bigeviltex7657
      @bigeviltex7657 2 роки тому

      @@ThrownSparksGarage thnx for the reply, video was informational. had to watcha few to get everything understood but no one ever mentions that the bigger compressor tanks produce so much heat. It kinda had me worried. I know the actual pumps do but was not aware the actual tanks get hot.

  • @jadriel81
    @jadriel81 Рік тому

    What side fittings did you use/order?

    • @ThrownSparksGarage
      @ThrownSparksGarage  Рік тому

      I can’t remember off the top of my head, but I believe it was standard size. They had everything I needed at my local hardware store.

  • @ElBee378
    @ElBee378 4 роки тому +2

    WHAT ARE THOOOOOSE?!? 👟🐊

  • @kappaPR
    @kappaPR 11 місяців тому

    i need to reduce pressure

  • @dmoya936
    @dmoya936 3 роки тому

    Hi this compresor it’s 120 volt ??

  • @waynemanor8357
    @waynemanor8357 3 роки тому

    seeing that makes my hernia repair hurt.

  • @mikeammargon6847
    @mikeammargon6847 2 роки тому

    hey buddy what size breaker did you go with?

    • @ThrownSparksGarage
      @ThrownSparksGarage  2 роки тому +1

      I believe the owners manual call out a draw of 15A for this motor. I used a 20A breaker since I had a spare one laying around.

    • @mikeammargon6847
      @mikeammargon6847 2 роки тому

      @@ThrownSparksGarage never tripped out???

    • @ThrownSparksGarage
      @ThrownSparksGarage  2 роки тому +1

      @@mikeammargon6847 I haven't had issues with it. Depending on the size wire you use and the length from your breaker to the compressor you may need to adjust. But 20 amp has worked for me.

    • @josealequin2912
      @josealequin2912 Рік тому

      30 amp work good.

  • @mariabutandarojas7930
    @mariabutandarojas7930 3 роки тому

    Cuánto tarda en llenar

  • @Yotaciv
    @Yotaciv Рік тому

    Thats how you void the warranty

  • @eddy3061
    @eddy3061 3 роки тому

    tried to lift mine. ya, right