How to Check Evaporator Superheat

Поділитися
Вставка
  • Опубліковано 27 лис 2024

КОМЕНТАРІ • 93

  • @HVACKnowItAll
    @HVACKnowItAll  4 роки тому +9

    It's not always the TXV!

    • @HVACToolReview
      @HVACToolReview 4 роки тому +1

      HVAC Know It All haha truth. you must be part of a few of the HVAC Facebook groups out there.

    • @lerch400block
      @lerch400block 3 роки тому +1

      When it is it is when it ain't you wasted a whole fucking day.

    • @jaxmoses4259
      @jaxmoses4259 3 роки тому

      instablaster.

  • @enemyofthesheeple
    @enemyofthesheeple Рік тому +1

    Great channel brother. I've been doing hvac/R for about 7 years. Still learning. Thanks for making videos Mr.Know it all. Lol

  • @hrdworkin7633
    @hrdworkin7633 3 роки тому +4

    Great tip! The way I remember is if you want to Lower superheat, you Loosen the screw.

  • @rubensabeast
    @rubensabeast 3 роки тому +3

    This just flipped the light bulb on lol thanks for the content brother

  • @sparkytech8787
    @sparkytech8787 3 роки тому +4

    love the detailed explanation brother, keep them coming, I just subscriber.

  • @ares3914
    @ares3914 Рік тому

    Very important in refrigeration. I run in many times I'm proper super heat and compressors failing in a few years.

  • @hvacmaster96
    @hvacmaster96 11 місяців тому

    the best explanation so far that I've seen, do you have a video and so on subcooling?

  • @RobRocker09
    @RobRocker09 6 місяців тому +1

    What about checking the condenser for the right freon pressures and checking the sight glass first. So the Condensers are running correctly, then check each evp.

  • @xraybravo7180
    @xraybravo7180 4 роки тому +1

    Nice video graphics,good view on tablet about pressures and saturation temps over all good sound and intro music

  • @chrisgormley5751
    @chrisgormley5751 4 роки тому +2

    Nice explanation about the txv and how to adjust it.

    • @HVACKnowItAll
      @HVACKnowItAll  4 роки тому +1

      Thanks Chris!

    • @farhanulrahman9302
      @farhanulrahman9302 7 місяців тому

      ​@HVACKnowItAll
      How to find what is optimal SH OR SC Requires for a 404a system

  • @randyandrews2743
    @randyandrews2743 4 роки тому +6

    Simple and to the point. Thank you.

  • @robbiebritt8997
    @robbiebritt8997 3 роки тому +3

    In regards to mini split heat pump units, if you are meant to use the sub cooling method as a way to check refrigerant charge because of EEV in outdoor unit, how are you able to do it if there is only 1 service port on the Suction line and nothing on the liquid line? a lot of mini split systems seem to have this set up. thanks!

  • @lorenzoontiveros7875
    @lorenzoontiveros7875 4 роки тому +1

    Thanks a lot for sharing that always scare me to try ,but u make look so easy thanks again

  • @RobRocker09
    @RobRocker09 9 місяців тому

    would you check the site glass at the condenser is see if its flashing first, then check each evap, great video

  • @halilcankaya3202
    @halilcankaya3202 Рік тому

    thank you sir , ı love testo equipments a lot bluetooth connection is very usefull

  • @zekenzy6486
    @zekenzy6486 4 роки тому +2

    Great video. Happy weekend ^_^

  • @xraybravo7180
    @xraybravo7180 4 роки тому +1

    Great video Mr.

  • @mehdimirzaei451
    @mehdimirzaei451 7 місяців тому

    Easy explanation thanks buddy

  • @edram1909
    @edram1909 3 роки тому

    Great video and thank you for sharing your knowledge! any tips for new techs in the commercial refrigeration field?

    • @dnoorian
      @dnoorian 3 роки тому

      ya, follow @dnoorian

  • @JaykeSapalaran-iq3qs
    @JaykeSapalaran-iq3qs Рік тому

    Great video tutorial ❤ thank you for sharing your knowledge and experience 🫡🇵🇭♥️

  • @mikegamer2732
    @mikegamer2732 Рік тому

    Nice sir. I like your tools

  • @ashkarpk094
    @ashkarpk094 9 місяців тому

    nice explanation brother..

  • @supertech_hvac851
    @supertech_hvac851 10 місяців тому

    Great content tech

  • @hectortorres542
    @hectortorres542 Рік тому

    Thank you. If you have a chance to show the old school way with gages would be cool.

  • @michaelminihan6430
    @michaelminihan6430 Рік тому

    Nice.
    Great info

  • @nbctcp3450
    @nbctcp3450 11 місяців тому

    Home split aircond R32
    1. how to find target superheat in Celcius
    2. do u hv chart for it
    3. what remote temp do u set i.e 24 celcius, low fan, no swing

  • @benfranqui5283
    @benfranqui5283 2 роки тому +1

    Great job thanks

  • @videos10
    @videos10 Рік тому

    When adjusting the txv valve, and it does not respond to any turns whatsoever. Not allowing the SH to change. Would this mean txv is bad?

  • @mochamadyani
    @mochamadyani 3 роки тому

    Great video

  • @eugenenel2486
    @eugenenel2486 2 роки тому +1

    What make instrument are you using to measure super heat?

  • @6metal6forever6
    @6metal6forever6 4 роки тому +1

    Looking to get a set of the Testo Smart probes. Do the probes and the app have the capability to log data and display graphs of the pressures and temps?

    • @HVACKnowItAll
      @HVACKnowItAll  4 роки тому +1

      In graph form yes, data logging yes as long as your phone says beside them. You cant set them up and leave for a couple days and leave. For a couple of hours no problem.

    • @6metal6forever6
      @6metal6forever6 4 роки тому

      @@HVACKnowItAll
      Thats a bit unfortunate. I was hoping to have the probes connected on the system whilst diagnosing other faults on site without having to leave my phone/tablet behind. thanks for your reply

  • @ajayibabatundesamuel5663
    @ajayibabatundesamuel5663 6 місяців тому

    if the expansion valve is manufuntion on chiller what cam l do

  • @AlexiFernando-qy9fg
    @AlexiFernando-qy9fg Рік тому

    Sir, How much SH is adequate for a -40°C Blast Chiller using 404a refrigerant in 63KW system with 150 HP Screw compressor ?

  • @sknight0391
    @sknight0391 Рік тому

    Beautiful !!! 😎👍

  • @carlosemmanuelgarciabrito791
    @carlosemmanuelgarciabrito791 3 роки тому

    Nice video mate but clear my mind I read on google the for must system superheat at the evap should be 6-8 walk in cooler and 4-6 freezer can u explain that for me

    • @icecoldfridgy1729
      @icecoldfridgy1729 Рік тому +1

      You typically want your evap SH to be low, so you can ensure you are using more of the coil to boil off the refrigerant. High evap SH means you're loosing evap efficiency. You also have to be worried about too much system SH as to not overheat refrigerant cooled compressors, it's bad for the oil.

  • @angrynas9668
    @angrynas9668 5 місяців тому +1

    Cheking superheat near desire temperature

  • @hvactech2966
    @hvactech2966 7 місяців тому

    Nice video

  • @goldencoolingsolution
    @goldencoolingsolution 11 місяців тому

    Is Equalizer after expansion valve bulbe

  • @timetotravel5886
    @timetotravel5886 Рік тому

    Awesome bro

  • @marjoneantifuesto4503
    @marjoneantifuesto4503 Рік тому

    thanks

  • @ananthakrishnanm7717
    @ananthakrishnanm7717 3 роки тому +1

    Can you provide details of pressure and temperature measuring device

  • @raviyadav8743
    @raviyadav8743 3 роки тому +1

    Sir , how to find out proper gas charge in system by measure superheat .?

    • @HVACKnowItAll
      @HVACKnowItAll  3 роки тому

      You need to measure super heat and subcooling

  • @wasimedoo7994
    @wasimedoo7994 Рік тому

    Very good information 👍

  • @abdullah_q8171
    @abdullah_q8171 2 роки тому

    So if i need more cooler to my package unit?

  • @360hvac5
    @360hvac5 Рік тому

    Thanks you

  • @texture6
    @texture6 Рік тому

    The medium used to absorb the heat, the refrigerant.
    Is related to the amount which increase or decrease
    The Superheat
    You want the right amount of refrigerant which relates to the right amount of heat absorption

  • @CubanMofo
    @CubanMofo Рік тому

    What happens if you permanently take off the sensoing bulb of the

  • @jw9396
    @jw9396 Місяць тому

    ? how do you do this without the app?

  • @Gianki00013
    @Gianki00013 2 роки тому +1

    Why are you checking superheat if there is a txv valve in the system?

    • @HVACKnowItAll
      @HVACKnowItAll  2 роки тому

      Tx valves still require an initial set up and periodical check.

  • @armandoacevedo932
    @armandoacevedo932 4 роки тому +1

    Good video's👍👍👍👍👍

  • @EnriqueRivera-v3i
    @EnriqueRivera-v3i 2 місяці тому +1

    4:17 pm you don’t check superheat on start up you need to be within at least 5 degrees of the temperature set point

  • @nhelzyoung2958
    @nhelzyoung2958 3 роки тому

    boss is that chiller evaporator system?

  • @kennethportes3706
    @kennethportes3706 3 роки тому

    Good day sir, about the app... How to use em

  • @HughesManHVAC
    @HughesManHVAC 4 роки тому +1

    Nice!

  • @AbdurRahim-ir9yz
    @AbdurRahim-ir9yz Рік тому

    sir your work places?

  • @stephwaylonwells3218
    @stephwaylonwells3218 2 роки тому

    👍

  • @anowarhossain2558
    @anowarhossain2558 2 роки тому

    Hi sir

  • @Kyle-sb8dj
    @Kyle-sb8dj 2 роки тому

    I always told myself lefty lessy and that stuck

  • @WPM_in_ATL
    @WPM_in_ATL 2 роки тому +1

    404, EH? Isn't that a freeway going north from the Don Valley Parkway? 😀 You sound like you are Canadian...if not, I will remove this comment. Having fun here in Virginia.

  • @MR-nl8xr
    @MR-nl8xr 4 роки тому

    I don't understand why we always adjust the stem on TXVs if they are MODULATING valves to begin with i.e. the TXV is going to adjust the needle pin for refrigerant flow to wherever the sending bulb tells it to.
    Adjusting the spring tension via the external stem is almost like playing with yourself, it feels good but doesn't make anything.
    That sending bulb and E.L. are going to tell that needle pin how much to open or close after everything is said and done anyways, do why bother.
    ???

  • @keepthinking2666
    @keepthinking2666 Рік тому +1

    Cap er lary not capil a ry

    • @HVACKnowItAll
      @HVACKnowItAll  Рік тому +1

      No bud, there's no such spelling as caperlary. The word is capillary - some pronounce it different than others.

  • @lerch400block
    @lerch400block 3 роки тому +1

    That is the wrong way to teach. Shortcuts lead to failure and misdiagnosis.