  • @ChristoffelTensors
    @ChristoffelTensors 2 роки тому +2

    This is simply one of the best controls engineering videos i have ever watched.

    • @realpars
      @realpars  2 роки тому

      That's amazing to hear!

  • @glennrager3684
    @glennrager3684 2 роки тому

    Thanks for this video. I used your code to read/write SCADA values to a CompactLogix controller every minute using a timer in VBA instead of command buttons (I used the buttons to enable/disable the timer). Works great after enabling the new DDE options in Excel 365 Trust Center, Windows 10. Also, we (a Wastewater Utility) had to purchase a license for RSLinx Classic Gateway, because the free Lite version doesn't support DDE even though it allowed me to configure a topic. Anyway, I appreciate your easily understandable video. Big help!

    • @realpars
      @realpars  2 роки тому +1

      Thanks a million for your support, Glenn! We appreciate that.

  • @Gustavoparaense
    @Gustavoparaense 4 роки тому +2

    I have been using Visual Basic 6 for over 10 years using the OPC Server DA protocol, the Korean brand LS PLC provides the driver for free

  • @halitekmekci8304
    @halitekmekci8304 4 роки тому +3

    I really like this channel, very informative and helpful. Good job!

    • @realpars
      @realpars  4 роки тому +1

      Amazing, Halit! Thanks for your support.

  • @PabloSanFerARI
    @PabloSanFerARI 2 роки тому +1

    Wow, so useful to integrate IT with OT

    • @realpars
      @realpars  2 роки тому

      Glad to hear that, Pablo!

  • @DuneKraftwerk
    @DuneKraftwerk 4 роки тому +3

    Wow... DDE, I use that 25 years ago on a PLC5 PLC. What about OPC UA ?

  • @maqsudaxhmedov8006
    @maqsudaxhmedov8006 4 роки тому

    Thanks RealPars for everyvideos

    • @realpars
      @realpars  4 роки тому +1

      You are very welcome!

  • @kalaivanan.l4147
    @kalaivanan.l4147 4 роки тому +2

    Quit superb, explain more about VBA.

    • @realpars
      @realpars  4 роки тому

      Thanks for your support!

  • @phuocanh19811
    @phuocanh19811 3 роки тому

    It's so clear training

    • @realpars
      @realpars  3 роки тому

      Glad to hear that!

  • @amjadhelo3598
    @amjadhelo3598 4 роки тому

    skilled engineer , thank realpars

  • @teamofdigital8890
    @teamofdigital8890 4 роки тому

    Thanks for sharing this lesson with us

    • @realpars
      @realpars  4 роки тому +1

      You are very welcome!

  • @thaddeusthomas3237
    @thaddeusthomas3237 Рік тому

    This is fantastic, thank you
    Is it possible to use this DDE methodology to similarly interact with PLCs from other Microsoft programs. Access or SharePoint for example?

    • @realpars
      @realpars  Рік тому +1

      Not all Microsoft products support DDE. Excel and Access do. SharePoint does not. DDE is being phased out in favor of other technologies, such as OPC.

  • @husamshalash8789
    @husamshalash8789 3 роки тому

    thanks for the sharing. could u make it simple for amatures like me and make videos for this important subject from the fundementals(Basics)?

  • @procontrolautomation2299
    @procontrolautomation2299 4 роки тому

    Very very good job! I appreciate this help.

    • @realpars
      @realpars  4 роки тому

      Great to hear that!

  • @kalybaizhalgasbai376
    @kalybaizhalgasbai376 4 роки тому +1

    Hello RealPars, can tell what kind of software do you use to make such kind of videos??

    • @realpars
      @realpars  4 роки тому

      Hi Kalybai,
      Thanks for your comment!
      I am actually not sure about this as this is done by our graphic and animation department.

  • @bighorse416
    @bighorse416 3 роки тому

    Great channel. What type of programming language do you use to write to the plc in your excel file

    • @realpars
      @realpars  3 роки тому +1

      There is no PLC programming done in Excel. OIn the video. Visual Basic for Applications (VBA) was used in macros to open a DDE communication channel between the: PC and the PLC communication driver. RSLinx, so that data can be shared with the PLC.

  • @guweizhao3430
    @guweizhao3430 2 роки тому +1

    how can Excel read CLX dynamic data in a certain time intervals automatically? and write to CLX?

    • @realpars
      @realpars  2 роки тому +1

      Great question! This would make for an interesting video course, I will go ahead and pass this on to our course developers as a topic suggestion.
      Many thanks for sharing and happy learning!

  • @Danyl96
    @Danyl96 4 роки тому

    Thanks for your videos!!! Pls, make video about DNP3.

    • @realpars
      @realpars  4 роки тому

      Hey!
      Thanks for your comment and your suggestion. I will pass this on to our course developers!
      Thanks for sharing and happy learning!

  • @lwke1296
    @lwke1296 24 дні тому

    What is the difference between RSLinx Classic and RSLinx Classic Gateway? They seemed to be used interchangeably in this video, even the program is named different things in the windows search box vs the program title.

    • @realpars
      @realpars  20 днів тому

      Hello @lwke1296 . Thank you for your question. Here is a link to learn more about it.
      rockwellautomation.custhelp.com/app/answers/answer_view/a_id/545290/~/differences-between-rslinx-classic-gateway-and-rslinx-classic-oem-
      Happy learning from RealPars!

  • @jaikumar2682
    @jaikumar2682 4 роки тому

    can u make more videos about allen bradley plc and RS logix software

    • @realpars
      @realpars  4 роки тому

      Hi Jai!
      Thanks for your comment and your suggestion. I will pass this on to our course developers!
      Thanks for sharing and happy learning!

  • @mohsenparizi2631
    @mohsenparizi2631 9 місяців тому

    Hi thanks.
    is it possible with pcs7 too?

    • @realpars
      @realpars  9 місяців тому

      Hi Mohsen,
      Thank you for your question. Yes, you can. Siemens has been doing this since 2012 or earlier. Below are two links you can explore for your learning.
      support.industry.siemens.com/forum/WW/en/posts/collecting-data-on-an-excel-sheet-using-dde-network/68902/?page=0&pageSize=10#top
      support.industry.siemens.com/cs/document/761667/dde-channel-to-excel-locally-on-a-computer?dti=0&lc=en-WW
      Happy learning!

  • @prestigiuseppe2659
    @prestigiuseppe2659 3 місяці тому

    Is it possible to do the same thing with Tia Portal from Siemens?

    • @realpars
      @realpars  2 місяці тому

      Thank you for your question. Yes, you can!
      Here is a link to Siemens TIA and other product information for your learning experience.
      support.industry.siemens.com/cs/document/109744173/documentation-for-simatic-controller?dti=0&lc=en-WW
      Happy learning!

  • @christopher8220
    @christopher8220 4 роки тому

    If I wanted to write successive data, say down a column, for post test data analysis, what command would I use in the excel file?

    • @realpars
      @realpars  4 роки тому

      You would need to write a VBA script to reference the cell location you want to populate. I would usually have a button control that when pressed, would start at a specified cell execute the method that will write the data in the cell to the PLC. Then after the write is confirmed, the script would increment the row number by one, and the write would proceed again, and so on. There are many powerful things you can do in scripting, which is the utility for automating manipulations in Excel. As a programming aid, when you record a macro, you are allowing Excel to do a lot of the programming work for you, as long as what you want to do is repetitive.

  • @pascalbradette3613
    @pascalbradette3613 3 роки тому

    DDEPoke dont work. No error, but notin write in PLC? Cant you help me? I use Office 365 desktop application. Thank you.

    • @pascalbradette3613
      @pascalbradette3613 3 роки тому

      Ok, I find! It does not seem possible to directly pass a value for writing ... The only way that seems to work is to pass through a cell. Thanks for the very educational video!

    • @realpars
      @realpars  3 роки тому +1

      Glad to hear that you have been able to resolve it, Pascal! If you have any other questions along the way, please feel free to reach out.

  • @casaautomation6107
    @casaautomation6107 4 роки тому

    GOOD

  • @superezbz
    @superezbz 3 роки тому

    I was under the impression that Windows 10 no longer supports DDE.

    • @glennrager3684
      @glennrager3684 2 роки тому +1

      Microsoft fixed it recently. New security options in Trust Center for DDE.

    • @superezbz
      @superezbz 2 роки тому +1

      @@glennrager3684 That's great news!

    • @glennrager3684
      @glennrager3684 2 роки тому +2

      @@superezbz I've been using it all week at work. Windows 10, Excel 365. It works great, same code as in this video. The only problem is we had to purchase a license for RSLinx Classsic Gateway, because all we had was the free Lite version.

    • @superezbz
      @superezbz 2 роки тому +1

      @@glennrager3684 That's definitely the biggest thing. Although I do like being able to do HMI and historian data on the cheap this way.

    • @glennrager3684
      @glennrager3684 2 роки тому +1

      @@superezbz Agreed. On the cheap. I've been doing Excel/VBA for data, graphics and charts for years, but never with live data. This opens up a whole new world for free HMI. Plus, I can write to Access for a free historian. Only thing missing is ability to serve multiple network clients with web pages. Someone smarter than me can probably figure that out with javascript, etc.

  • @phuciendj1572
    @phuciendj1572 4 роки тому

    This is higher level than my level. 😭😭😭😭😭